Wavelet Coherence Model for Diagnosis of Alzheimer Disease
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This article presents a wavelet coherence investigation of electroencephalograph (EEG) readings acquired from patients with Alzheimer disease (AD) and healthy controls. Pairwise electrode wavelet coherence is calculated over each frequency band (delta, theta, alpha, and beta). For comparing the synchronization fraction of 2 EEG signals, a wavelet coherence fraction is proposed which is defined as the fraction of the signal time during which the wavelet coherence value is above a certain threshold. A one-way analysis of variance test shows a set of statistically significant differences in wavelet coherence between AD and controls. The wavelet coherence method is effective for studying cortical connectivity at a high temporal resolution. Compared with other conventional AD coherence studies, this study takes into account the time–frequency changes in coherence of EEG signals and thus provides more correlational details. A set of statistically significant differences was found in the wavelet coherence among AD and controls. In particular, temporocentral regions show a significant decrease in wavelet coherence in AD in the delta band, and the parietal and central regions show significant declines in cortical connectivity with most of their neighbors in the theta and alpha bands. This research shows that wavelet coherence can be used as a powerful tool to differentiate between healthy elderly individuals and probable AD patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Application of the cross wavelet transform and wavelet coherence to geophysical time series
Grinsted, A., Moore, J. C., & Jevrejeva, S. (2004) · Nonlinear Processes in Geophysics · doi:10.5194/npg-11-561-2004 · Cited by 6,285
Cited by
Automated EEG analysis of epilepsy: A review
Acharya, U. R., Vinitha Sree, S., Swapna, G., Martis, R. J., & Suri, J. S. (2013) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.02.014 · Cited by 837
Wavelet-based EEG processing for computer-aided seizure detection and epilepsy diagnosis
Faust, O., Acharya, U. R., Adeli, H., & Adeli, A. (2015) · Seizure · doi:10.1016/j.seizure.2015.01.012 · Cited by 572
Self-citationSignal Processing Techniques for Vibration-Based Health Monitoring of Smart Structures
Amezquita-Sanchez, J. P., & Adeli, H. (2016) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9135-7 · Cited by 487
Self-citationEnsembles of Deep Learning Architectures for the Early Diagnosis of the Alzheimer’s Disease
Ortiz, A., Munilla, J., Górriz, J. M., & Ramírez, J. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065716500258 · Cited by 403
Systematic Review on Resting-State EEG for Alzheimer’s Disease Diagnosis and Progression Assessment
Cassani, R., Estarellas, M., San-Martin, R., Fraga, F. J., & Falk, T. H. (2018) · Disease Markers · doi:10.1155/2018/5174815 · Cited by 376
Metadata
- Authors
- Sankari, Z., Adeli, H., & Adeli, A.
- Venue
- Clinical EEG and Neuroscience
- Publisher
- SAGE Publications
- Published
- 2012-05-10
- Volume
- 43
- Issue
- 4
- Pages
- 268-278
- ISSN
- 1550-0594 (ISSN-L)
- 2169-5202
- OpenAlex
- W2024461202
- Cited by
- 134
- References
- 2
- FWCI
- 7.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wavelet Coherence Model for Diagnosis of Alzheimer Disease. https://app.cochat.ai/papers/10.1177/1550059412444970
- The paper
- Sankari, Z., Adeli, H., & Adeli, A. (2012). Wavelet Coherence Model for Diagnosis of Alzheimer Disease. Clinical EEG and Neuroscience. https://doi.org/10.1177/1550059412444970
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.