Proficiency-Based Laparoscopic Simulator Training Leads to Improved Operating Room Skill That Is Resistant to Decay
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The aim of this study was to assess skill retention in the operating room following completion of a proficiency-based laparoscopic skills curriculum. Novices (n = 15) were randomized to a control and a training group that practiced to proficiency on the Fundamentals of Laparoscopic Surgery suturing model. The performance of both groups was assessed on the simulator and on a live porcine laparoscopic Nissen fundoplication model at training completion (posttest) and 5 months later (retention test). Training to proficiency required 4.7 ±1.2 hours and 41 ± 10 repetitions. Trained participants outperformed controls, and their performance deteriorated slightly between posttests and retention tests on the simulator (505 ± 22 vs 462 ± 50, respectively; P < .05) but not in operating room (263 ± 138 vs 279 ± 88, respectively; P = .38). Proficiency-based simulator training results in durable improvement in operative skill of trainees even in the absence of practice for up to 5 months. Minute simulator performance changes do not translate to the operating room.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Factors That Influence Skill Decay and Retention: A Quantitative Review and Analysis
Arthur Jr., W., Bennett Jr., W., Stanush, P. L., & McNelly, T. L. (1998) · Human Performance · doi:10.1207/s15327043hup1101_3 · Cited by 664 · cited 2×
“The persistence of simulator-acquired skill is likely a consequence of the intensity and quality of training.(14,15,18) Proficiency-based simulator training consists of vigorous training in a safe environment that promotes deliberate practice, provides feedback on performance, and sets difficult but achievable expert-…”
Background
Cited by
Palter, V. N., Orzech, N., Reznick, R. K., & Grantcharov, T. P. (2013) · Annals of Surgery · doi:10.1097/sla.0b013e31827051cd · Cited by 168
Virtual Reality in Psychological, Medical and Pedagogical Applications
(2012) · doi:10.5772/2607 · Cited by 103
“[52] Ter Heijden N, Brinkman W-P (2011) Design and evaluation of a virtual reality exposure therapy system with free speech interaction.”
BackgroundInfluential
Metadata
- Authors
- Stefanidis, D., Acker, C., & Heniford, B. T.
- Venue
- Surgical Innovation
- Publisher
- SAGE Publications
- Published
- 2008-03
- Volume
- 15
- Issue
- 1
- Pages
- 69-73
- ISSN
- 1553-3506 (ISSN-L)
- 1553-3514
- OpenAlex
- W2089855898
- Cited by
- 164
- References
- 1
- FWCI
- 11.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Proficiency-Based Laparoscopic Simulator Training Leads to Improved Operating Room Skill That Is Resistant to Decay. https://app.cochat.ai/papers/10.1177/1553350608316683
- The paper
- Stefanidis, D., Acker, C., & Heniford, B. T. (2008). Proficiency-Based Laparoscopic Simulator Training Leads to Improved Operating Room Skill That Is Resistant to Decay. Surgical Innovation. https://doi.org/10.1177/1553350608316683
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.