Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement
Open accessThe DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
Glucose monitoring has become an integral part of diabetes care but has some limitations in accuracy. Accuracy may be limited due to strip manufacturing variances, strip storage, and aging. They may also be due to limitations on the environment such as temperature or altitude or to patient factors such as improper coding, incorrect hand washing, altered hematocrit, or naturally occurring interfering substances. Finally, exogenous interfering substances may contribute errors to the system evaluation of blood glucose. In this review, I discuss the measurement of error in blood glucose, the sources of error, and their mechanism and potential solutions to improve accuracy in the hands of the patient. I also discuss the clinical measurement of system accuracy and methods of judging the suitability of clinical trials and finally some methods of overcoming the inaccuracies. I have included comments about additional information or education that could be done today by manufacturers in the appropriate sections. Areas that require additional work are discussed in the final section.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Iontophoresis or reverse iontophoresis is based on the injection of current through the measurement site, which causes migration of ions and glucose from the ISF to the surface and electrodes 100.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [100]
In the citing paper
“In the case of glucose oxidase-based monitors, physiological and pharmacological interfering substances for glucose readings include uric acid, galactose, xylose, L-DOPA, acetaminophen, and ascorbic acid 100,106,107.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [100]
In the citing paper
“Many variables, including hematocrit, hypoxemia, hypotension, temperature, altitude, and humidity may influence the reliability of glucose measurements 52,100.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [100]
In the citing paper
“Glucose oxidase-based devices are sensitive to oxygen and should be only used with capillary blood from patients with normal oxygen saturation. In case of higher oxygen tension (oxygen therapy or arterial blood), glucose readings are falsely low, while in case of lower oxygen tension (hypoxia, high altitude, venous blood), test results are falsely high 100,103.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [100]
In the citing paper
“Also, studies have highlighted that glucose levels in the blood, as well as in ISF (and likely in other biofluids) are influenced by commonly used pharmacological treatments (e.g., acetaminophen, albuterol, lisinopril, atenolol, and atorvastatin).”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [100]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 16 · Cited by 348
Research works printed but not linked: 4
- International Organization for Standardization, 2003, In vitro diagnostic test systems. Requirements for blood-glucose monitoring system for self-testing in managing diabetes mellitus
- Bamberg R, 2005, Clin Lab Sci., 18, 203
- Parkes JL, 2004, Accuracy of blood glucose meters by patients, technicians and nurses
- Ginsberg BH, 2006, Common food and lotion interfering substances
Metadata
- Authors
- Ginsberg, B. H.
- Affiliations
- Diabetes Technology Consultants, Wyckoff, New Jersey
- Corresponding author
- Ginsberg, Barry H.
- ORCID
- Ginsberg, Barry H.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2009-07
- Volume
- 3
- Issue
- 4
- Pages
- 903-913
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2769960
- OpenAlex
- W2139893169
- Semantic Scholar
- 617cfb93761a6617399886697abb56bbf56bf980
- Cited by
- 348
- References
- 16
- Citations by year
- 2026: 8 · 2025: 12 · 2024: 13 · 2023: 14 · 2022: 28 · 2021: 22 · 2020: 23 · 2019: 32 · 2018: 30 · 2017: 16 · 2016: 31 · 2015: 27 · 2014: 16 · 2013: 31 · 2012: 23
- FWCI
- 9.72
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Keywords
- blood glucose monitoring, measurement error, diabetes management, glucose meter accuracy, environmental interference, hematocrit, interfering substances, patient factors
- MeSH terms
- Blood Glucose, Blood Specimen Collection, Diabetes Mellitus, Humans, Reagent Strips, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement. https://app.cochat.ai/papers/10.1177/193229680900300438
- The paper
- Ginsberg, B. H. (2009). Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680900300438
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.