CoChat

Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement

Open access
Ginsberg, Barry H. · 2009 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

Glucose monitoring has become an integral part of diabetes care but has some limitations in accuracy. Accuracy may be limited due to strip manufacturing variances, strip storage, and aging. They may also be due to limitations on the environment such as temperature or altitude or to patient factors such as improper coding, incorrect hand washing, altered hematocrit, or naturally occurring interfering substances. Finally, exogenous interfering substances may contribute errors to the system evaluation of blood glucose. In this review, I discuss the measurement of error in blood glucose, the sources of error, and their mechanism and potential solutions to improve accuracy in the hands of the patient. I also discuss the clinical measurement of system accuracy and methods of judging the suitability of clinical trials and finally some methods of overcoming the inaccuracies. I have included comments about additional information or education that could be done today by manufacturers in the appropriate sections. Areas that require additional work are discussed in the final section.

Overview

Integrity signals

Registry

Crossref · 10.1177/193229680900300438

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

The citation lists are queued

They are fetched later and appear here then.

References 16 · Cited by 348

Research works printed but not linked: 4

  1. International Organization for Standardization, 2003, In vitro diagnostic test systems. Requirements for blood-glucose monitoring system for self-testing in managing diabetes mellitus
  2. Bamberg R, 2005, Clin Lab Sci., 18, 203
  3. Parkes JL, 2004, Accuracy of blood glucose meters by patients, technicians and nurses
  4. Ginsberg BH, 2006, Common food and lotion interfering substances

Metadata

Authors
Ginsberg, B. H.
Affiliations
Diabetes Technology Consultants, Wyckoff, New Jersey
Corresponding author
Ginsberg, Barry H.
Venue
Journal of Diabetes Science and Technology
Published
2009-07
Volume
3
Issue
4
Pages
903-913
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2139893169
Cited by
348
References
16
Citations by year
2026: 8 · 2025: 12 · 2024: 13 · 2023: 14 · 2022: 28 · 2021: 22 · 2020: 23 · 2019: 32 · 2018: 30 · 2017: 16 · 2016: 31 · 2015: 27 · 2014: 16 · 2013: 31 · 2012: 23
FWCI
9.72
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
Keywords
blood glucose monitoring, measurement error, diabetes management, glucose meter accuracy, environmental interference, hematocrit, interfering substances, patient factors
MeSH terms
Blood Glucose, Blood Specimen Collection, Diabetes Mellitus, Humans, Reagent Strips, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement. https://app.cochat.ai/papers/10.1177/193229680900300438
The paper
Ginsberg, B. H. (2009). Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680900300438

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.