Frequently Repeated Glucose Measurements Overestimate the Incidence of Inpatient Hypoglycemia and Severe Hyperglycemia
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: The aim was to determine if frequently repeated glucose measurements mandated by an inpatient protocol led to falsely elevated reported rates of both hypo- and hyperglycemia. Methods: In our academic medical center, a mandatory standardized subcutaneous insulin order form and protocol was implemented in May 2006. We analyzed point-of-care blood glucose (BG) measurements collected on all medical/surgical wards during the month of August in both 2005 and 2006 by all BGs measured, by patient admission, and by monitored patient-day. We then repeated all analyses using an algorithm that excluded BG values if another BG was measured less than 5 minutes later or 5–60 minutes earlier. Results: In 2005 versus 2006, there were 7034 versus 8016 glucoses measured in 397 versus 389 patients over 1704 versus 1710 patient days, respectively. Analyses based on patient-day balanced differences in BG measurement frequency and patient length of stay. In both years, failure to exclude repeat values overestimated both the proportion of patient days with hypoglycemia (3.5% versus 1.8% in 2005, p = .003; 2.6% versus 1.3% in 2006, p = .007) and severe hyperglycemia (9.3% versus 7.4% in 2005, p = .09; 7.7% versus 5.9% in 2006, p = .08). Mean, median, and proportion of patient-day means within our target range (80–150 mg/dl) were not significantly different. Conclusions: Glucometric reports should exclude repeated BG measurements from a single clinical episode of hypo- or hyperglycemia in order to accurately reflect inpatient glycemic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy and pentastarch resuscitation in severe sepsis
Brunkhorst, F. M., Engel, C., Bloos, F., Meier-Hellmann, A., Ragaller, M., Weiler, N., Moerer, O., Gruendling, M., Oppert, M., Grond, S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070716 · Cited by 2,921
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794 · cited 2×
“This algorithm would exclude glucose values (1) when the initial glucose result is spurious (e.”
BackgroundMethodUmpierrez, G. E., Smiley, D., Zisman, A., Prieto, L. M., Palacio, A., Ceron, M., Puig, A., & Mejia, R. (2007) · Diabetes Care · doi:10.2337/dc07-0295 · Cited by 671
Cited by
Rushakoff, R. J., Sullivan, M. M., MacMaster, H. W., Shah, A. D., Rajkomar, A., Glidden, D. V., & Kohn, M. A. (2017) · Annals of Internal Medicine · doi:10.7326/m16-1413 · Cited by 91
Self-citationKyi, M., Colman, P. G., Wraight, P. R., Reid, J., Gorelik, A., Galligan, A., Kumar, S., Rowan, L. M., Marley, K. A., Nankervis, A. J., et al. (2019) · Diabetes Care · doi:10.2337/dc18-2342 · Cited by 86
Mehta, P. B., Kohn, M. A., Rov-Ikpah, E., San Luis, C., Johnson, C., Lee, G., Koliwad, S., & Rushakoff, R. J. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241232673 · Cited by 7
Self-citation
Metadata
- Authors
- Weinberg, M. E., Bacchetti, P., & Rushakoff, R. J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-05
- Volume
- 4
- Issue
- 3
- Pages
- 577-582
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2165543242
- Cited by
- 35
- References
- 3
- FWCI
- 0.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequently Repeated Glucose Measurements Overestimate the Incidence of Inpatient Hypoglycemia and Severe Hyperglycemia. https://app.cochat.ai/papers/10.1177/193229681000400311
- The paper
- Weinberg, M. E., Bacchetti, P., & Rushakoff, R. J. (2010). Frequently Repeated Glucose Measurements Overestimate the Incidence of Inpatient Hypoglycemia and Severe Hyperglycemia. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681000400311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.