Use of an Automated Bolus Calculator Reduces Fear of Hypoglycemia and Improves Confidence in Dosage Accuracy in Patients with Type 1 Diabetes Mellitus Treated with Multiple Daily Insulin Injections
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background: Many patients do not intensify their insulin regimens. It is believed that lack of adherence may be largely due to fear of hypoglycemia. We hypothesized that utilization of an automated bolus calculator (bolus advisor) might reduce fear of hypoglycemia and encourage patients to achieve improved glycemic control. Method: We surveyed 1,412 type 1 diabetes mellitus (T1DM) patients treated with multiple daily insulin injection therapy at 270 hospitals in the United Kingdom and Republic of Ireland to assess their attitudes and behaviors regarding insulin therapy after use of a bolus advisor (Accu-Chek® Aviva Expert blood glucose meter and bolus advisor system, Roche Diagnostics). The device automatically calculates bolus dosages based on current blood glucose values, anticipated meal intake, and other parameters. Results: Five hundred eighty-eight T1DM patients responded to the survey. Respondents were predominantly female, age <1 to 70 years, with diabetes duration of <1 to >15 years. Respondents had 4–12 weeks prior experience using the bolus advisor. 76.7% of respondents indicated current bolus advisor use to calculate insulin boluses for meals/snacks always or quite often. 52.0% of respondents indicated that fear of hypoglycemia was reduced (39.0%) or significantly reduced (13.0%). 78.8% indicated that confidence in the insulin dose calculation improved (50.8%) or significantly improved (28.0%). 89.3% indicated that the bolus advisor made bolus calculation easy or very easy compared with manual calculation. Conclusions: Most patients felt that using the bolus advisor was easier than manual bolus calculation, improved their confidence in the accuracy of their bolus dosage, and reduced their fear of hypoglycemia. Randomized trials are needed to confirm these perceptions and determine whether bolus advisor use improves clinical outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Effect of a multifactorial intervention on mortality in type 2 diabetes
Gæde, P., Lund-Andersen, H., Parving, H.-H., & Pedersen, O. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706245 · Cited by 3,465
Wild, D., von Maltzahn, R., Brohan, E., Christensen, T., Clauson, P., & Gonder-Frederick, L. (2007) · Patient Education and Counseling · doi:10.1016/j.pec.2007.05.003 · Cited by 545
Diverse causes of hypoglycemia-associated autonomic failure in diabetes.
Cryer, P. E. (2004) · New England Journal of Medicine · doi:10.1056/nejmra031354 · Cited by 411
Fear of hypoglycaemia in adults with type 1 diabetes
Anderbro, T., Amsberg, S., Adamson, U., Bolinder, J., Lins, P. ‐., Wredling, R., Moberg, E., Lisspers, J., & Johansson, U. ‐. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2010.03078.x · Cited by 128
Type 1 Diabetes Among Adolescents
Di Battista, A. M., Hart, T. A., Greco, L., & Gloizer, J. (2009) · The Diabetes Educator · doi:10.1177/0145721709333492 · Cited by 123
Moreland, E. C., Volkening, L. K., Lawlor, M. T., Chalmers, K. A., Anderson, B. J., & Laffel, L. M. B. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.6.689 · Cited by 2
Cited by
Annan, S. F., Higgins, L. A., Jelleryd, E., Hannon, T., Rose, S., Salis, S., Baptista, J., Chinchilla, P., & Marcovecchio, M. L. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13429 · Cited by 143
Fear of hypoglycemia---an underestimated problem
Przezak, A., Bielka, W., & Molęda, P. (2022) · Brain and Behavior · doi:10.1002/brb3.2633 · Cited by 110
Reddy, M., Pesl, P., Xenou, M., Toumazou, C., Johnston, D., Georgiou, P., Herrero, P., & Oliver, N. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0413 · Cited by 70
A novel pen-based Bluetooth-enabled insulin delivery system with insulin dose tracking and advice
Bailey, T. S., & Stone, J. Y. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2017.1313831 · Cited by 60
Choudhary, P., & Amiel, S. A. (2018) · Diabetologia · doi:10.1007/s00125-018-4566-6 · Cited by 52
Metadata
- Authors
- Barnard, K., Parkin, C., Young, A., & Ashraf, M.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2012-01
- Volume
- 6
- Issue
- 1
- Pages
- 144-149
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2112274344
- Cited by
- 92
- References
- 8
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of an Automated Bolus Calculator Reduces Fear of Hypoglycemia and Improves Confidence in Dosage Accuracy in Patients with Type 1 Diabetes Mellitus Treated with Multiple Daily Insulin Injections. https://app.cochat.ai/papers/10.1177/193229681200600117
- The paper
- Barnard, K., Parkin, C., Young, A., & Ashraf, M. (2012). Use of an Automated Bolus Calculator Reduces Fear of Hypoglycemia and Improves Confidence in Dosage Accuracy in Patients with Type 1 Diabetes Mellitus Treated with Multiple Daily Insulin Injections. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681200600117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.