Overview of a Novel Sensor for Continuous Glucose Monitoring
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The core element of a continuous glucose monitoring (CGM) system is the glucose sensor, which should enable reliable CGM readings in the interstitial fluid in subcutaneous tissue for a period of several days. The aim of this article is to describe the layout and constituents of a novel glucose sensor and the rationale behind the measures that were used to optimize its performance. In order to achieve a stable glucose sensor signal, special attention was paid to the sensor materials and architecture, i.e., biocompatible coating of the sensor, limitation of glucose flux into the working electrode, low oxidation potential by use of manganese dioxide, and a tissue-averaging sensor design. A series of in vitro and in vivo evaluations showed that the sensor enables stable and accurate glucose sensing in the subcutaneous tissue for up to 7 days. Parallel measurements with four sensors in a single patient showed a close agreement between these sensors. In summary, this high-performance needle-type glucose sensor is well suited for CGM in patients with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variants of the tissue-sensor array window chamber
Makale, M. T., Chen, P. C., & Gough, D. A. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01001.2004 · Cited by 16
Cited by
Measures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices
Freckmann, G., Pleus, S., Grady, M., Setford, S., & Levy, B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818812062 · Cited by 202
Time Delay of CGM Sensors: Relevance, Causes, and Countermeasures
Schmelzeisen-Redeker, G., Schoemaker, M., Kirchsteiger, H., Freckmann, G., Heinemann, L., & del Re, L. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815590154 · Cited by 161
Self-citationLimits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials
Schrangl, P., Reiterer, F., Heinemann, L., Freckmann, G., & Del Re, L. (2018) · Biosensors · doi:10.3390/bios8020050 · Cited by 46
“It must be mentioned that the time delay between both signals was also caused by additional factors, such as time required for the measurement and filters used (see [49,50]).”
BackgroundRecent advances in computational tools and resources for the self-management of type 2 diabetes
Moonian, O., Jodheea-Jutton, A., Khedo, K. K., Baichoo, S., Nagowah, S. D., Nagowah, L., Mungloo-Dilmohamud, Z., & Cheerkoot-Jalim, S. (2020) · Informatics for Health and Social Care · doi:10.1080/17538157.2018.1559168 · Cited by 15
“19 Two main approaches include marginally invasive amperometric sensors that are implanted into the subcutaneous tissue and fully non-invasive wearable sensors for interstitial fluid measurement.”
Background
Metadata
- Authors
- Schmelzeisen-Redeker, G., Staib, A., Strasser, M., Müller, U., & Schoemaker, M.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2013-07
- Volume
- 7
- Issue
- 4
- Pages
- 808-814
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W1805875852
- Cited by
- 43
- References
- 1
- Type
- conference abstract
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Overview of a Novel Sensor for Continuous Glucose Monitoring. https://app.cochat.ai/papers/10.1177/193229681300700402
- The paper
- Schmelzeisen-Redeker, G., Staib, A., Strasser, M., Müller, U., & Schoemaker, M. (2013). Overview of a Novel Sensor for Continuous Glucose Monitoring. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.