Cited by 175Diabetes Management and ResearchElectrochemical sensors and biosensorsPancreatic function and diabetes

Continuous Glucose Monitoring Devices: Past, Present, and Future Focus on the History and Evolution of Technological Innovation

Open access
Didyuk, Olesya, Econom, Nicolas, Guardia, Angelica, Livingston, Kelsey, Klueh, Ulrike·2021·Journal of Diabetes Science and Technology

Abstract

The concept of implantable glucose sensors has been promulgated for more than 40 years. It is now accepted that continuous glucose monitoring (CGM) increases quality of life by allowing informed diabetes management decisions as a result of more optimized glucose control. The focus of this article is to provide a brief overview of the CGM market history, emerging technologies, and the foreseeable challenges for the next CGM generations as well as proposing possible solutions in an effort to advance the next generation of implantable sensor.

Integrity signals

Registry

Crossref · 10.1177/1932296819899394

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Evaluating the correlation between the menstrual cycle and glycaemic control in type 1 diabetes has been challenging due to the need for intensive glucose monitoring, which has become accurate only in recent decades.

    “the need for intensive glucose monitoring, which has become accurate only in recent decades thanks to the implementation of flash and continuous glucose monitoring systems [2]”

The citation lists haven’t been fetched yet

References 49 · Cited by 175

Authors
Didyuk, O., Econom, N., Guardia, A., Livingston, K., & Klueh, U.
Affiliations
Wayne State University (US)
Corresponding author
Klueh, Ulrike
Venue
Journal of Diabetes Science and Technology
Published
2020-01-13
Volume
15
Issue
3
Pages
676-683
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2999666543
Cited by
175
References
49
Citations by year
2026: 26 · 2025: 45 · 2024: 39 · 2023: 35 · 2022: 16 · 2021: 8 · 2020: 6
FWCI
2.49
Type
journal article
Language
en
Open access
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (P30DK020572)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
Keywords
continuous glucose monitoring, implantable glucose sensor, diabetes management, glycemic control, technological innovation
MeSH terms
Blood Glucose, Humans, Insulin Infusion Systems, Quality of Life, Blood Glucose Self-Monitoring, Inventions

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review