CoChat

Accuracy and Precision of Continuous Glucose Monitoring in Hospitalized Patients Undergoing Radiology Procedures

Open access
Migdal, Alexandra L., Spanakis, Elias K., Galindo, Rodolfo J., Davis, Georgia, Singh, Lakshmi G., Satyarengga, Medha, Scott, William H., Fayfman, Maya, Pasquel, Francisco J., Albury, Bonnie, Urrutia, Maria, Zamudio Coronado, K. Walkiria, Cardona, Saumeth, Peng, Limin, Umpierrez, Guillermo E. · 2020 · Journal of Diabetes Science and Technology
Cited by 40

The DOI matches its Crossref record.

Abstract

The use of continuous glucose monitoring (CGM) has increased steadily over the past decade.1 As these devices become more pervasive in the outpatient setting, there is increasing interest in using CGM for inpatient management of diabetes. This raises concerns regarding safety in the setting of radiology imaging. Current industry guidelines recommend removal of devices when undergoing certain radiology procedures due to potential interference with CGM system functioning.2 Expert opinion has suggested placing a lead apron over the device prior to x-ray, CT scan, or catheterization procedures.3,4 However, there is no published data on the impact of radiation and contrast exposure on CGM precision and accuracy to support these recommendations. We monitored 49 adult medicine and surgery patients with type 1 and type 2 diabetes who used Dexcom G6 CGM (Dexcom, San Diego, CA, USA) devices during hospitalization. Glycemic data were collected before and after radiology procedures (x-rays, n = 28; CT scan, n = 13; catheterization/ angiography, n = 8) without lead apron protection. Patients undergoing magnetic resonance imaging (MRI) were excluded. The primary outcome was glycemic variability by coefficient of variation (%CV) measured by CGM two hours preand post-imaging. Secondary outcome was the mean absolute relative difference (MARD) between matched capillary point-of-care (POC) and CGM glucose values preand post-imaging. There was no significant difference in mean CGM blood glucose (BG) or %CV for all imaging procedures combined (delta mean BG: −7.7 ± 26.0, P = .051; %CV 18.0% pre vs 19.1% post, P = .65) or when stratified by x-ray only (delta mean BG: −8.8 ± 29.9, P = 0.15, %CV 20.1% pre vs 21.5% post, P = .60) vs CT scan/catheterization/angiography (delta mean BG: −6.3 ± 20.6, P = .19, %CV 15.2% pre vs 15.9% post, P = .97). The overall MARD was 13.3% preimaging and 12.7% post-imaging. The overall percentage of glucose values within ±15%/15 mg/dL, ±20%/20 mg/dL, and ±30%/30 mg/dL of the POC reference value was 69%, 80%, and 94%, respectively, pre-imaging, and 68%, 82%, and 93% post-imaging. Clarke Error Grid analysis showed 98.1% of glucoses falling into Zones A and B pre-imaging and 99.7% post-imaging (Figure 1). This is the first report to describe the effects of radiology imaging on CGM functionality. Our data indicate that ongoing usage during radiology procedures is safe and reliable without interference in CGM data transmission. Recommendations to remove devices prior to imaging may 930038 DSTXXX10.1177/1932296820930038Journal of Diabetes Science and TechnologyMigdal et al. letter2020

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296820930038

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 40

Metadata

Authors
Migdal, A. L., Spanakis, E. K., Galindo, R. J., Davis, G., Singh, L. G., Satyarengga, M., Scott, W. H., Fayfman, M., Pasquel, F. J., Albury, B., Urrutia, M., Zamudio Coronado, K. W., Cardona, S., Peng, L., & Umpierrez, G. E.
Venue
Journal of Diabetes Science and Technology
Published
2020-06-01
Volume
14
Issue
6
Pages
1135-1136
ISSN
1932-2968 (ISSN-L)
OpenAlex
W3031072025
Cited by
40
References
0
FWCI
3.82
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and Precision of Continuous Glucose Monitoring in Hospitalized Patients Undergoing Radiology Procedures. https://app.cochat.ai/papers/10.1177/1932296820930038
The paper
Migdal, A. L., Spanakis, E. K., Galindo, R. J., Davis, G., Singh, L. G., Satyarengga, M., Scott, W. H., Fayfman, M., Pasquel, F. J., Albury, B., Urrutia, M., Zamudio Coronado, K. W., Cardona, S., Peng, L., & Umpierrez, G. E. (2020). Accuracy and Precision of Continuous Glucose Monitoring in Hospitalized Patients Undergoing Radiology Procedures. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296820930038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.