Mitigation of Rebound Hyperglycemia With Real-Time Continuous Glucose Monitoring Data and Predictive Alerts
Open accessThe DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
Background: Excess carbohydrate intake during hypoglycemia can lead to rebound hyperglycemia (RH). We investigated associations between RH and use of real-time continuous glucose monitoring (rtCGM) and an rtCGM system’s predictive alert. Methods: RH events were series of sensor glucose values (SGVs) >180 mg/dL starting within two hours of an antecedent SGV <70 mg/dL. Events were characterized by their frequency, duration (consecutive SGVs >180 mg/dL × five minutes), and severity (area under the glucose concentration-time curve). To assess the impact of rtCGM, data gathered during the four-week baseline phase (without rtCGM) and four-week follow-up phase (with rtCGM) from 75 participants in the HypoDE clinical trial (NCT02671968) of hypoglycemia-unaware individuals were compared. To assess the impact of predictive alerts, we identified a convenience sample of 24 518 users of an rtCGM system without predictive alerts who transitioned to a system whose predictive alert signals an SGV ≤55 mg/dL within 20 minutes (Dexcom G5 and G6, respectively). RH events from periods of blinded versus unblinded rtCGM wear and from periods of G5 and G6 wear were compared with paired t tests. Results: Compared to RH events in the HypoDE baseline phase, the mean frequency, duration, and severity of events fell by 14%, 12%, and 23%, respectively, in the follow-up phase (all P < .05). Compared to RH events during G5 use, the mean frequency, duration, and severity of events fell by 7%, 8%, and 13%, respectively, during G6 use (all P < .001). Conclusions: Rebound hypreglycemia can be objectively quantified and mitigated with rtCGM and rtCGM-based predictive alerts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“This was a rather strict definition for rebound hyperglycemia, because most time-in-range recommendations allow up to 10 mmol/L as the upper threshold [14–16].”
From Systematic review of oral carbohydrate treatment for hypoglycemia in people living with type 2 diabetes mellitus (2026) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists are queued
They are fetched later and appear here then.
References 22 · Cited by 27
Research works printed but not linked: 1
- Abraham SB, J Diabetes Sci Technol, 2019, 193229681985933
Metadata
- Authors
- Acciaroli, G., Welsh, J. B., & Akturk, H. K.
- Affiliations
- Dexcom (United States) (US)
- Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, CO, USA
- Corresponding author
- Welsh, John B.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2021-01-05
- Volume
- 16
- Issue
- 3
- Pages
- 677-682
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC9294577
- OpenAlex
- W3118745697
- Cited by
- 27
- References
- 22
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2023: 8 · 2022: 2 · 2021: 4
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dexcom, Inc.
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- rebound hyperglycemia, hypoglycemia, continuous glucose monitoring, hypoglycemia unawareness, Dexcom G6, carbohydrate intake, glycemic variability
- MeSH terms
- Blood Glucose, Diabetes Mellitus, Type 1, Humans, Hyperglycemia, Hypoglycemia, Hypoglycemic Agents, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mitigation of Rebound Hyperglycemia With Real-Time Continuous Glucose Monitoring Data and Predictive Alerts. https://app.cochat.ai/papers/10.1177/1932296820982584
- The paper
- Acciaroli, G., Welsh, J. B., & Akturk, H. K. (2022). Mitigation of Rebound Hyperglycemia With Real-Time Continuous Glucose Monitoring Data and Predictive Alerts. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296820982584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.