CoChat

Diabetic Retinopathy Screening Using Artificial Intelligence and Handheld Smartphone-Based Retinal Camera

Open access
Malerbi, Fernando Korn, Andrade, Rafael Ernane, Morales, Paulo Henrique, Stuchi, José Augusto, Lencione, Diego, de Paulo, Jean Vitor, Carvalho, Mayana Pereira, Nunes, Fabrícia Silva, Rocha, Roseanne Montargil, Ferraz, Daniel A., Belfort, Rubens · 2022 · Journal of Diabetes Science and Technology
Cited by 98

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Background: Portable retinal cameras and deep learning (DL) algorithms are novel tools adopted by diabetic retinopathy (DR) screening programs. Our objective is to evaluate the diagnostic accuracy of a DL algorithm and the performance of portable handheld retinal cameras in the detection of DR in a large and heterogenous type 2 diabetes population in a real-world, high burden setting. Method: Participants underwent fundus photographs of both eyes with a portable retinal camera (Phelcom Eyer). Classification of DR was performed by human reading and a DL algorithm (PhelcomNet), consisting of a convolutional neural network trained on a dataset of fundus images captured exclusively with the portable device; both methods were compared. We calculated the area under the curve (AUC), sensitivity, and specificity for more than mild DR. Results: A total of 824 individuals with type 2 diabetes were enrolled at Itabuna Diabetes Campaign, a subset of 679 (82.4%) of whom could be fully assessed. The algorithm sensitivity/specificity was 97.8 % (95% CI 96.7-98.9)/61.4 % (95% CI 57.7-65.1); AUC was 0·89. All false negative cases were classified as moderate non-proliferative diabetic retinopathy (NPDR) by human grading. Conclusions: The DL algorithm reached a good diagnostic accuracy for more than mild DR in a real-world, high burden setting. The performance of the handheld portable retinal camera was adequate, with over 80% of individuals presenting with images of sufficient quality. Portable devices and artificial intelligence tools may increase coverage of DR screening programs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296820985567

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 98

Metadata

Authors
Malerbi, F. K., Andrade, R. E., Morales, P. H., Stuchi, J. A., Lencione, D., de Paulo, J. V., Carvalho, M. P., Nunes, F. S., Rocha, R. M., Ferraz, D. A., & Belfort, R.
Venue
Journal of Diabetes Science and Technology
Published
2021-01-12
Volume
16
Issue
3
Pages
716-723
ISSN
1932-2968 (ISSN-L)
OpenAlex
W3119237119
Cited by
98
References
8
FWCI
8.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diabetic Retinopathy Screening Using Artificial Intelligence and Handheld Smartphone-Based Retinal Camera. https://app.cochat.ai/papers/10.1177/1932296820985567
The paper
Malerbi, F. K., Andrade, R. E., Morales, P. H., Stuchi, J. A., Lencione, D., de Paulo, J. V., Carvalho, M. P., Nunes, F. S., Rocha, R. M., Ferraz, D. A., & Belfort, R. (2022). Diabetic Retinopathy Screening Using Artificial Intelligence and Handheld Smartphone-Based Retinal Camera. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296820985567

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.