CoChat

Milan ultrasound criteria are accurate in assessing disease activity in ulcerative colitis: external validation

Open access

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Introduction: The aim of this study was to provide an external validation of bowel ultrasound (US) predictors of activity in ulcerative colitis (UC) and quantitative Milan Ultrasound Criteria (MUC). Methods: Forty‐three consecutive patients with UC (16 in endoscopic remission and 27 with endoscopic activity) underwent bowel US and colonoscopy in a tertiary referral inflammatory bowel disease unit. Results: An MUC score >6.2 discriminated patients with active versus non‐active UC with a sensitivity of 0.85 (95% confidence interval (CI) 0.66–0.96), specificity of 0.94 (95% CI 0.70–0.99) and an area under the curve of 0.902 (95% CI 0.772–0.971) in complete agreement with the derivation study. Conclusion: The external validation of MUC confirms that it is an accurate tool for assessing disease activity in patients with UC.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2050640620980203

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Figures

FIGURE 1 Distribution of the Milan Ultrasound Criteria (MUC) in a cohort of patients with ulcerative colitis
FIGURE 1 Distribution of the Milan Ultrasound Criteria (MUC) in a cohort of patients with ulcerative colitisCC BY-NC-ND · PubMed Central
FIGURE 2 Comparison of receiver operating characteristic curves: ‘Milan Ultrasound Criteria (MUC) alone’ (continuous line) versus ‘MUC + FC’ (dashed line). No statistically significant difference was observed (p = 0.101). FC, faecal calprotectin
FIGURE 2 Comparison of receiver operating characteristic curves: ‘Milan Ultrasound Criteria (MUC) alone’ (continuous line) versus ‘MUC + FC’ (dashed line). No statistically significant difference was observed (p = 0.101). FC, faecal calprotectinCC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 107

Metadata

Authors
Allocca, M., Filippi, E., Costantino, A., Bonovas, S., Fiorino, G., Furfaro, F., Peyrin‐Biroulet, L., Fraquelli, M., Caprioli, F., & Danese, S.
Affiliations
  • Humanitas University (IT)
  • Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT)
  • Department of Gastroenterology Humanitas Clinical and Research Center ‐ IRCCS Milan Italy
  • Inserm (FR)
  • University of Milan (IT)
Corresponding author
Allocca, Mariangela
Venue
United European Gastroenterology Journal
Publisher
Wiley
Published
2021-02-16
Volume
9
Issue
4
Pages
438-442
ISSN
  • 2050-6406 (ISSN-L)
  • 2050-6414
OpenAlex
W3117488486
Cited by
107
References
10
Citations by year
2026: 22 · 2025: 24 · 2024: 22 · 2023: 16 · 2022: 13 · 2021: 10
FWCI
5.71
Type
journal article
Language
en
Open access
Licence
Locations
  • United European Gastroenterology Journal (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca (Universita Degli Studi Di Milano) (submittedVersion, other-oa)
  • HAL (submittedVersion, cc-by-nc-nd)
  • Archivio Istituzionale della Ricerca - Università Vita-Salute San Raffaele (submittedVersion)
Topics
  • Health Sciences › Medicine › Gastroenterology › Inflammatory Bowel Disease
  • Health Sciences › Medicine › Gastroenterology › Microscopic Colitis
  • Health Sciences › Medicine › Ophthalmology › Ocular Diseases and Behçet’s Syndrome
Keywords
ulcerative colitis, bowel ultrasound, disease activity assessment, external validation, endoscopic activity, inflammatory bowel disease, diagnostic accuracy
MeSH terms
Adult, Colitis, Ulcerative, Colon, Colonoscopy, Feces, Humans, Intestinal Mucosa, Prospective Studies, Sensitivity and Specificity, Ultrasonography, Biomarkers, Area Under Curve, Leukocyte L1 Antigen Complex

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Milan ultrasound criteria are accurate in assessing disease activity in ulcerative colitis: external validation. https://app.cochat.ai/papers/10.1177/2050640620980203
The paper
Allocca, M., Filippi, E., Costantino, A., Bonovas, S., Fiorino, G., Furfaro, F., Peyrin‐Biroulet, L., Fraquelli, M., Caprioli, F., & Danese, S. (2021). Milan ultrasound criteria are accurate in assessing disease activity in ulcerative colitis: external validation. United European Gastroenterology Journal. https://doi.org/10.1177/2050640620980203

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.