Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Intra-laboratory turnaround time (TAT) is a key indicator of laboratory performance. Improving TAT is a complex task requiring staff education, equipment acquisition, and adequate TAT monitoring. The aim of the present study was to evaluate the intra-laboratory TAT after laboratory automation implementation (June 2013-June 2014) and to compare it to that in the preautomation period (July 2012-May 2013). Intra-laboratory TAT was evaluated both as the mean TAT registered and the percentage of outlier (OP) exams. The mean TAT was 36, 38, and 34 min during the study periods, respectively. These values respected the goal TAT established at 45 min. The OP, calculated at 45 min as well as at 60 min, decreased from 26 to 21 and from 11 to 5, respectively. From a focused analysis on blood count cell, troponin I, and prothrombin (PT) test, TAT improvement was more evident for tests requiring longer preanalytical process. The follow-up of TAT from June 2013 to June 2014 revealed the reduction of the mean TAT as well as of the OP exams after automation implementation and that automation more strongly affects the test in the preanalytical phase including centrifugation of the sample, such as troponin I and PT.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Longer LOS not only increases direct costs (room charges, nursing care) but also exposes patients to higher risks of hospital-acquired infections (HAIs), falls, and other iatrogenic complications, further degrading outcomes and increasing cost [19].”
From Impact of Laboratory Turnaround Time on Clinical Decision-Making and Patient Outcomes (2024) · cites this paper as [19]
In the citing paper
“Such improvements have been shown to reduce the TAT [26–30].”
From Shorter laboratory turnaround time is associated with shorter emergency department length of stay: a retrospective cohort study (2022) · cites this paper as [30]
Citations
Cites
Point-of-Care Testing Reduces Length of Stay in Emergency Department Chest Pain Patients
Singer, A. J., Ardise, J., Gulla, J., & Cangro, J. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.11.020 · Cited by 149
Reducing Laboratory Turnaround Time Outliers Can Reduce Emergency Department Patient Length of Stay
Holland, L. L., Smith, L. L., & Blick, K. E. (2005) · American Journal of Clinical Pathology · doi:10.1309/e9qp-vq6g-2fbv-mj3b · Cited by 137 · cited 1×
“The delay in urgent exams has been reported to have a major impact on the diagnosis and management of patients and on length of stay in the emergency department.(12) Laboratory automation has been described as an important means of improving the efficiency of the laboratory and TAT observance.”
MethodKilgore, M. L., Steindel, S. J., & Smith, J. A. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.8.1597 · Cited by 127 · cited 1×
“The therapeutic TAT for laboratory assays includes the entire interval from test order to the initiation of a therapeutic intervention based on the test results.(5) The time from order to specimen collection as well as time for transport to the laboratory are difficult to control; thus, laboratories prefer to use intr…”
MethodTurn Around Time (TAT) as a Benchmark of Laboratory Performance
Goswami, B., Singh, B. M., Chawla, R., Gupta, V. K., & Mallika, V. (2010) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-010-0056-4 · Cited by 109 · cited 1×
“Intra-laboratory TAT is an important indicator of laboratory quality and performance.(10) TAT represents a key factor influencing patient care.”
BackgroundLaboratory Results: Timeliness as a Quality Attribute and Strategy
Howanitz, J. H., & Howanitz, P. J. (2001) · American Journal of Clinical Pathology · doi:10.1309/h0dy-6vtw-nb36-u3l6 · Cited by 108 · cited 1×
“Howanitz and Howanitz(4) reported that TAT can be improved by staff education, long-term planning, and even small investments in the laboratory, such as front-end automation that centrifuges, decaps, prepares aliquots, and sorts samples.(4) In a previous study, we reported our experience of intralaboratory TAT improve…”
BackgroundValenstein, P. (1996) · American Journal of Clinical Pathology · doi:10.1093/ajcp/105.6.676 · Cited by 87
Quality assurance measurements in departments of pathology and laboratory medicine.
Howanitz, P. J. (1990) · PubMed · Cited by 82
The Role of Total Laboratory Automation in a Consolidated Laboratory Network
Seaberg, R. S., Stallone, R. O., & Statland, B. E. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.5.751 · Cited by 77 · cited 1×
“Laboratory automation has been described as an important means of improving the efficiency of the laboratory and TAT observance.(9,13,14) In the present study, TAT was analyzed before and after laboratory automation implementation to evaluate the impact of automation on stat samples management.”
MethodSárközi, L., Simson, E., & Ramanathan, L. V. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00020-2 · Cited by 70 · cited 1×
“Laboratory automation has been described as an important means of improving the efficiency of the laboratory and TAT observance.(9,13,14) In the present study, TAT was analyzed before and after laboratory automation implementation to evaluate the impact of automation on stat samples management.”
MethodHolland, L. L., Smith, L. L., & Blick, K. E. (2006) · American Journal of Clinical Pathology · doi:10.1309/3j5p9vjrup4u5ru5 · Cited by 61 · cited 1×
“The percentage of outlier exams decreased at 45 min from 26% to 21%, as well as at 60 min from 11% to 5%, with the aim of obtaining urgent exam results within 60 min in 95% of cases and an OP below 5%.(8) These decrease is evident after complete automation layout was reached (January–June 2014), as reported in Figure…”
Background
Research works printed but not linked: 2
- Angeletti, 2014, Monitoring and Improvement of Intra Laboratory Turnaround Time at the University Hospital Campus Bio-Medico in Rome, Biochim. Clin., 38, 115
- Holland, 2005, Reducing Laboratory Turn around Time Outliers Reduces Emergency Department (ED) Patient Length of Stay (LOS): An 11 Hospital Study, Am. J. Clin. Pathol., 124, 672, 10.1309/e9qpvq6g2fbvmj3b · doi:10.1309/e9qpvq6g2fbvmj3b · Paper page
Cited by
Advantages and limitations of total laboratory automation: a personal overview
Lippi, G., & Da Rin, G. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-1323 · Cited by 163
Automation and artificial intelligence in the clinical laboratory
Naugler, C., & Church, D. L. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1561640 · Cited by 112
“Automation in these areas of the laboratory has been shown to not only reduce the overall test turnaround time but also the percentage of outlier examinations and the demand for STAT testing [19,21,33,34].”
BackgroundConsolidation of Clinical Microbiology Laboratories and Introduction of Transformative Technologies
Vandenberg, O., Durand, G., Hallin, M., Diefenbach, A., Gant, V. A., Murray, P. R., Kozlakidis, Z., & van Belkum, A. (2020) · Clinical Microbiology Reviews · doi:10.1128/cmr.00057-19 · Cited by 87
“Many examples of such advantages of automation to reduce patient identification error rate exist in clinical chemistry (78, 79).”
BackgroundTotal laboratory automation: Do stat tests still matter?
Dolci, A., Giavarina, D., Pasqualetti, S., Szőke, D., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.04.002 · Cited by 79
Clinical Laboratory Automation: A Case Study
Archetti, C., Montanelli, A., Finazzi, D., Caimi, L., & Garrafa, E. (2017) · Journal of Public Health Research · doi:10.4081/jphr.2017.881 · Cited by 68
Revolutionizing Laboratory Practices: Pioneering Trends in Total Laboratory Automation
Nam, Y., & Park, H. (2025) · Annals of Laboratory Medicine · doi:10.3343/alm.2024.0581 · Cited by 54
Evaluation of the impact of a total automation system in a large core laboratory on turnaround time
Lou, A. H., Elnenaei, M. O., Sadek, I., Thompson, S., Crocker, B., & Nassar, B. A. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.08.018 · Cited by 54
The Impact of Total Automaton on the Clinical Laboratory Workforce: A Case Study
Alnaam, Y., Elsafi, S. H., Aljahdali, M. H., Shaman, R. S. A., Al-Qurouni, B. H., & Zahrani, E. M. A. (2022) · Journal of Healthcare Leadership · doi:10.2147/jhl.s362614 · Cited by 44
Lou, A. H., Elnenaei, M. O., Sadek, I., Thompson, S., Crocker, B., & Nassar, B. A. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.04.019 · Cited by 42
Bhatt, R. D., Shrestha, C., & Risal, P. (2019) · PubMed Central · Cited by 34
Vrijsen, B. E. L., Haitjema, S., Westerink, J., Hulsbergen-Veelken, C. A. R., van Solinge, W. W., & ten Berg, M. J. (2022) · BMC Emergency Medicine · doi:10.1186/s12873-022-00763-w · Cited by 20
Total laboratory automation: fit for its intended purposes?
Plebani, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0855 · Cited by 19
“Comparable fi ndings have likewise been observed in relation to STAT tests [6] while other authors have emphasized the importance of clinical governance and professional oversight to ensure that improvements in TAT are e ff ectively achieved [7].”
Miler, M., Nikolac, N., Dukić, L., & Šimundić, A.-M. (2017) · Journal of Medical Systems · doi:10.1007/s10916-017-0878-1 · Cited by 17
Rapid Centrifugation in the Routine Hemostasis Laboratory
Wolfensberger, N., Georgiou, G. K., Giabbani, E., Reusser, M., Njue, L. M., Fiedler, M., Leichtle, A. B., & Nagler, M. (2019) · Thrombosis and Haemostasis · doi:10.1055/s-0039-1696712 · Cited by 14
Effects of Automation on Sustainability of Immunohistochemistry Laboratory
Đorđević, M., Životić, M., Škodrić, S. R., Ostojić, J. N., Lipkovski, J. M., Filipović, J., Ćirović, S., Kovačević, S., & Đunđerović, D. (2021) · Healthcare · doi:10.3390/healthcare9070866 · Cited by 11
“Automation improves performances in clinical laboratories [12], but it still represents a great challenge, considering the implementation of numerous changes required for the successful automation of procedures, involving a completely new approach to managing the existing processes.”
BackgroundAlain, C. B., Rostin, M. M. M., Joël, K. N. N., Mavoko, H. M., Donatien, K. N.-N., Tanon, K. A., Jérémie, M. M., & Hippolyte, S. N.-T. (2021) · Journal of Biosciences and Medicines · doi:10.4236/jbm.2021.97011 · Cited by 11
“Among these three phases, pre-analytical and post-analytical phases contribute to nearly 96% of the TAT [22].”
Critical Issues and New Trends on Stat Tests in Clinical Laboratory.
Arbiol‐Roca, A., & Dot-Bach, D. (2019) · PubMed Central · Cited by 11
Tseng, C.-W., Li, Y.-C., Lee, H., & Tseng, Y.-M. (2024) · Laboratory Medicine · doi:10.1093/labmed/lmae044 · Cited by 8
Rubin, D., Cassin, M., Morandini, M., Cappelletti, P., Veneziani, F., Burgio, M. A., Manno, M. L., Stenner, E., Moretti, M., Marino, G., et al. (2018) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-018-0192-z · Cited by 7
Naveen, K. G., Ahmad, S., Kumar, P., Mahto, M., & Bharti, S. (2026) · Cureus · doi:10.7759/cureus.100703 · Cited by 6
“However, timely and precise reports enable early diagnosis, appropriate treatment, and improved patient outcomes, thereby reducing healthcare costs associated with extended hospital stays [5,8-10].”
Characterization of add-on testing before and after automation at a core laboratory
García‐Osuna, Á., Guiñón, L., Costa-Pallaruelo, M., Usero, A. M., Eduardo, B. C., Ramos, J. L., Canyelles, M., Martínez-Brú, C., & Illana, F. J. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e22096 · Cited by 6
“This improvement is important, as it could have a major positive impact on the diagnosis and management of patients and on the length of stay in the ED [16].”
BackgroundZubanov, P. S., Tregub, P. P., Goldberg, A. S., Godkov, M. A., & Акимкин, В. Г. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0323 · Cited by 6
Park, M., Kim, Y.-J., Jung, D., Kim, Y., Kim, H. M., Lee, Y., & Choi, I. Y. (2023) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.12.017 · Cited by 6
Innovation, Automation and Informatics Improves Quality in Lerdsin Hospital, Thailand
Karnchanaphiboonwong, A., Sringam, P., Niwattakul, K., Krommuang, T., & Gammie, A. J. (2023) · British Journal of Biomedical Science · doi:10.3389/bjbs.2023.11532 · Cited by 4
Goyit, M., Emmanuel, I., & Longwap, A. S. (2020) · Journal of BioMedical Research and Clinical Practice · doi:10.46912/jbrcp.196 · Cited by 3
Teyim, P. M., Priscillia, A. A., Mendjime, P., Donfack, V. F. D., Mfouapon, M. Y., Beloko, H., Prudence, B. N. A., Linda, E., & Mballa, G. A. E. (2025) · PLoS ONE · doi:10.1371/journal.pone.0323917 · Cited by 3
Automation and miniaturization of high-throughput qPCR for gene expression profiling
Raveendran, S., Saeed, A., Kalikiri, M. K. R., Manjunath, H. S., Massih, A. A., Hashmi, M. A., Al-Azwani, I. K., Kabeer, B. S. A., Mathew, R., & Tomei, S. (2024) · SLAS TECHNOLOGY · doi:10.1016/j.slast.2024.100241 · Cited by 2
Managing an automated clinical laboratory: optimization challenges and opportunities
Archetti, C., Speranza, M. G., & Garrafa, E. (2019) · EURO Journal on Decision Processes · doi:10.1007/s40070-019-00097-2 · Cited by 2
Adikari, P. S., Alwis, S. D., & Karunanayake, L. (2020) · International Journal of Online and Biomedical Engineering (iJOE) · doi:10.3991/ijoe.v16i09.13799 · Cited by 2
“A University Hospital study recorded faster TAT by laboratory automation [18].”
MethodRabaan, A. A., & Al‐Tawfiq, J. A. (2021) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1093/trstmh/trab014 · Cited by 2
Impact of Laboratory Turnaround Time on Clinical Decision-Making and Patient Outcomes
Alanazi, A. G. J., Hanbouli, T. M. H. A., Albarqi, A. S. M., Aldoghmani Turki Kateb, D., Rowili, N. H. O. A., Jhory, K. E. A., Bokhari, A. M. K., Alanazi, A. A., Alenezi, T. M. R., Alawidia Ahmad Issa, A., et al. (2024) · International Journal of Computational and Experimental Science and Engineering · doi:10.22399/ijcesen.4675 · Cited by 1
“Longer LOS not only increases direct costs (room charges, nursing care) but also exposes patients to higher risks of hospital-acquired infections (HAIs), falls, and other iatrogenic complications, further degrading outcomes and increasing cost [19].”
Corrective Steps in a Total Laboratory Automation: Experience of a University Laboratory
Yıldız, R., & Ulman, C. (2023) · Journal of Turkish Clinical Biochemistry · doi:10.56615/tkbd.2023.17 · Cited by 1
Gupta, N., Kundu, S., Nandi, K., Suchiita, A., & Koner, B. C. (2024) · Journal of Laboratory Physicians · doi:10.25259/jlp_111_2024 · Cited by 1
Maripin, N., Maradi, R., Belle, V. S., & Joshi, V. R. (2025) · Interciencia · doi:10.59671/nr0mj · Cited by 1
Laboratuvar Sonuç Verme Sürelerinin Değerlendirilmesi
Demirağcı, Y. G. (2018) · Celal Bayar Üniversitesi Sağlık Bilimleri Enstitüsü Dergisi · Cited by 1
Chandradasa, D. H. N. S., & Dalpadadu, K. C. S. (2020) · International Journal of Scientific and Research Publications · doi:10.29322/ijsrp.10.10.2020.p10610 · Cited by 1
Are Medical Technologists still needed in Medical Laboratories in a Technologically Advanced Future?
Cutamora, E. B., Cortes, K. C., & Pepito, J. A. (2022) · Journal of Health and Medical Sciences · doi:10.31014/aior.1994.05.03.230 · Cited by 1
Demirağcı, Y. G., Taneli, F., Onur, E., Arı, Z., Özyurt, B. C., Özdemir, H., Taştan, İ., & Ulman, C. (2019) · Dokuz Eylül Üniversitesi Tıp Fakültesi Dergisi · doi:10.5505/deutfd.2019.26122
“arttırdığı ve süreç kontrolü üzerine etkili olduğu gösterilmiştir (30).”
Γκίκα, Ε. (2020) · Dione (University of Piraeus) · doi:10.26267/unipi_dione/472
Miti, S., Chisenga, C. C., Mubanga, C., Msimuko, L., Manda, C., Zulu, C., Kalaba, N. M., Niyongabo, C. M., Chisapi, L., Thole, D., et al. (2024) · medRxiv · doi:10.1101/2024.03.07.24303953
Correlation of factor XIII subunit A with factor XIII activity in a population of parturient women
Frevert, M. L., Burgi, J. J., Brun, R., Hothorn, T., Rösslein, M., Ochsenbein‐Kölble, N., Haslinger, C., & Korte, W. C. (2024) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-024-07799-2
Total automation of medical biology laboratories
Benghezel, H., & Sadelaoud, M. (2024) · Batna Journal of Medical Sciences (BJMS) · doi:10.48087/bjmsra.2024.11106
Automated Diagnostic Technologies: Enhancing Clinical Efficiency Through Robotics
Kaur, P., & Mahajan, R. (2024) · International Conference on Advanced Computing & Communication Technologies (ICACCTech) · doi:10.1109/icacctech65084.2024.00098
CLINICAL LABORATORY AUTOMATION: A COST EVALUATION
ARCHETTI, C., Caimi, L., GARRAFA, E. M., & Montanelli, A. (2016) · Institutional Research Information System (Università degli Studi di Brescia)
Güven, B., & Can, M. (2026) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2025.83723
Spoliti, C., CRISTOFARO, R. D., & Stasio, E. D. (2026) · Diagnostics · doi:10.3390/diagnostics16132120
“Among these phases, the analytical component is the most directly controllable and used to assess internal laboratory performance [15].”
Radhakrishnan, A. (2026) · SBS Journal of Applied Business Research
Total laboratory Automation - Is it always a boon?
Singla, H., & Goyal, G. (2021) · International Journal of Biomedical Research
Ahmad, D., Sharma, S. S. K., & Sabharwal, M. (2026) · Research Square · doi:10.21203/rs.3.rs-10915117/v1
Metadata
- Authors
- Angeletti, S., De Cesaris, M., Hart, J. G., Urbano, M., Vitali, M. A., Fragliasso, F., & Dicuonzo, G.
- Affiliations
- Università Campus Bio-Medico (IT)
- Campus Bio Medico University Hospital (IT)
- Corresponding author
- Angeletti, Silvia
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 20
- Issue
- 6
- Pages
- 652-658
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W1995321013
- Cited by
- 38
- References
- 13
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 6 · 2023: 4 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 7 · 2018: 1 · 2017: 4 · 2016: 1
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 2314 d)
- Locations
- SLAS TECHNOLOGY (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Keywords
- laboratory automation, pre-analytical phase, troponin I, prothrombin time
- MeSH terms
- Diagnostic Tests, Routine, Hospitals, University, Humans, Rome, Time Factors, Automation, Laboratory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.