Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The transition to total automation represents the greatest leap for a clinical laboratory, characterized by a totally new philosophy of process management. We have investigated the impact of total automation on core laboratory efficiency and its effects on the clinical services related to STAT tests. For this purpose, a 47-month retrospective study based on the analysis of 44,212 records of STAT cardiac troponin I (CTNI) tests was performed. The core laboratory reached a new efficiency level 3 months after the implementation of total automation. Median turnaround time (TAT) was reduced by 14.9±1.5 min for the emergency department (p < 0.01), reaching 41.6±1.2 min. In non-emergency departments, median TAT was reduced by 19.8±2.2 min (p < 0.01), reaching 52±1.3 min. There was no change in the volume of ordered STAT CTNI tests by the emergency department (p = 0.811), whereas for non-emergency departments there was a reduction of 115.7±50 monthly requests on average (p = 0.026). The volume of ordered tests decreased only in time frames of the regular shift following the morning round. Thus, total automation significantly improves the core laboratory efficiency in terms of TAT. As a consequence, the volume of STAT tests ordered by hospital departments (except for the emergency department) decreased due to reduced duplicated requests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Efficient TAT, coupled with robust critical value reporting protocols, is essential for closing the loop on abnormal findings and ensuring they are acted upon [20].”
From Impact of Laboratory Turnaround Time on Clinical Decision-Making and Patient Outcomes (2024) · cites this paper as [20]
In the citing paper
“Such improvements have been shown to reduce the TAT [26–30].”
From Shorter laboratory turnaround time is associated with shorter emergency department length of stay: a retrospective cohort study (2022) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Writing Committee Members, Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000134791.68010.fa · Cited by 8,356
WRITING COMMITTEE MEMBERS*, O’Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182742cf6 · Cited by 4,725
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1193 · Cited by 4,487
Segmented regression analysis of interrupted time series studies in medication use research
Wagner, A. K., Soumerai, S. B., Zhang, F., & Ross-Degnan, D. (2002) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1046/j.1365-2710.2002.00430.x · Cited by 3,279 · cited 1×
“However, if the ordinary least squares regression is chosen, results may be unreliable because of autocorrelation that arises in data due to the way they are collected (serially) throughout time.(26) In our case, a longer period of observation allowed us to recognize the presence of some change points in the trend tha…”
Method2013 ACCF/AHA Guideline for the Management of ST-Elevation Myocardial Infarction
O'Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., Franklin, B. A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.019 · Cited by 2,625
Intervention Analysis with Applications to Economic and Environmental Problems
Box, G. E. P., & Tiao, G. C. (1975) · Journal of the American Statistical Association · doi:10.1080/01621459.1975.10480264 · Cited by 2,383
Hawkins, R. C. (2007) · PubMed · Cited by 404
Newby, L. K., Jesse, R. L., Babb, J. D., Christenson, R. H., De Fer, T. M., Diamond, G. A., Fesmire, F. M., Geraci, S. A., Gersh, B. J., Larsen, G. C., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.969 · Cited by 402
How to do (or not to do) … Assessing the impact of a policy change with routine longitudinal data
Lagarde, M. (2012) · Health Policy and Planning · doi:10.1093/heapol/czr004 · Cited by 290
2007 WRITING COMMITTEE MEMBERS, Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828478ac · Cited by 272
Research works printed but not linked: 2
- Simulation Modelling: A Tool to Help Predict the Impact of Automation in Clinical Laboratory. W Godolphin, K Bodtker, L Wilson, Lab. Robot. Autom. 41992
- The Impact of Laboratory Automation on Performance Improvement. L Brannon Thomas, A A Borkowski, M Rubero-Lung, Fed. Pract. 252008
Cited by
Advantages and limitations of total laboratory automation: a personal overview
Lippi, G., & Da Rin, G. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-1323 · Cited by 163
Automation and artificial intelligence in the clinical laboratory
Naugler, C., & Church, D. L. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1561640 · Cited by 112
“outlier examinations and the demand for STAT testing [19,21,33,34].”
BackgroundTotal laboratory automation: Do stat tests still matter?
Dolci, A., Giavarina, D., Pasqualetti, S., Szőke, D., & Panteghini, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.04.002 · Cited by 80
Turnaround Time: An Efficacy Measure for Medical Laboratories
Dawande, P. P., Wankhade, R., Akhtar, F. I., & Noman, O. (2022) · Cureus · doi:10.7759/cureus.28824 · Cited by 80
Clinical Laboratory Automation: A Case Study
Archetti, C., Montanelli, A., Finazzi, D., Caimi, L., & Garrafa, E. (2017) · Journal of Public Health Research · doi:10.4081/jphr.2017.881 · Cited by 69
Revolutionizing Laboratory Practices: Pioneering Trends in Total Laboratory Automation
Nam, Y., & Park, H. (2025) · Annals of Laboratory Medicine · doi:10.3343/alm.2024.0581 · Cited by 57
Evaluation of the impact of a total automation system in a large core laboratory on turnaround time
Lou, A. H., Elnenaei, M. O., Sadek, I., Thompson, S., Crocker, B., & Nassar, B. A. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.08.018 · Cited by 54
Shiferaw, M. B., & Yismaw, G. (2019) · BMC Health Services Research · doi:10.1186/s12913-019-4077-2 · Cited by 50
The Impact of Total Automaton on the Clinical Laboratory Workforce: A Case Study
Alnaam, Y., Elsafi, S. H., Aljahdali, M. H., Shaman, R. S. A., Al-Qurouni, B. H., & Zahrani, E. M. A. (2022) · Journal of Healthcare Leadership · doi:10.2147/jhl.s362614 · Cited by 46
Lou, A. H., Elnenaei, M. O., Sadek, I., Thompson, S., Crocker, B., & Nassar, B. A. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.04.019 · Cited by 42
Performance characteristics of the Abbott Alinity m SARS-CoV-2 assay
Perchetti, G. A., Pepper, G., Shrestha, L., LaTurner, K., Kim, D. Y., Huang, M.-L. W., Jerome, K. R., & Greninger, A. L. (2021) · Journal of Clinical Virology · doi:10.1016/j.jcv.2021.104869 · Cited by 26
Chung, H., Song, Y. K., Hwang, S., Lee, D. H., & Sugiura, T. (2018) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22400 · Cited by 22
Vrijsen, B. E. L., Haitjema, S., Westerink, J., Hulsbergen-Veelken, C. A. R., van Solinge, W. W., & ten Berg, M. J. (2022) · BMC Emergency Medicine · doi:10.1186/s12873-022-00763-w · Cited by 20
Ialongo, C., Pieri, M., & Bernardini, S. (2016) · SLAS TECHNOLOGY · doi:10.1177/2211068216636635 · Cited by 18
Self-citationCoşkun, A., & Ialongo, C. (2020) · Biochemia Medica · doi:10.11613/bm.2020.010901 · Cited by 14
Self-citationTanasijevic, M. J., Melanson, S. E. F., Tolan, N. V., Ransohoff, J. R., Michael J Conrad, M., Paik, H. H.-I., & Petrides, A. K. (2020) · Laboratory Medicine · doi:10.1093/labmed/lmaa108 · Cited by 13
Effects of Automation on Sustainability of Immunohistochemistry Laboratory
Đorđević, M., Životić, M., Škodrić, S. R., Ostojić, J. N., Lipkovski, J. M., Filipović, J., Ćirović, S., Kovačević, S., & Đunđerović, D. (2021) · Healthcare · doi:10.3390/healthcare9070866 · Cited by 11
Impact of total automation consolidating first-line laboratory tests on diagnostic blood loss
Pasqualetti, S., Aloisio, E., Birindelli, S., Dolci, A., & Panteghini, M. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0133 · Cited by 9
Timeliness “at a glance”: assessing the turnaround time through the six sigma metrics
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.010 · Cited by 9
Self-citationTseng, C.-W., Li, Y.-C., Lee, H., & Tseng, Y.-M. (2024) · Laboratory Medicine · doi:10.1093/labmed/lmae044 · Cited by 8
Collaborative Robotics, Mobile Platforms, and Total Laboratory Automation in Clinical Diagnostics
Mukherjee, S., Lambert, C., Zhou, Y., Kan, S., Yang, J., Liao, G., Flygare, S. D., & Ohgami, R. S. (2026) · Diagnostics · doi:10.3390/diagnostics16040518 · Cited by 8
Ialongo, C. (2019) · Biochemia Medica · doi:10.11613/bm.2019.030101 · Cited by 8
Self-citationRubin, D., Cassin, M., Morandini, M., Cappelletti, P., Veneziani, F., Burgio, M. A., Manno, M. L., Stenner, E., Moretti, M., Marino, G., et al. (2018) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-018-0192-z · Cited by 7
Naveen, K. G., Ahmad, S., Kumar, P., Mahto, M., & Bharti, S. (2026) · Cureus · doi:10.7759/cureus.100703 · Cited by 6
Characterization of add-on testing before and after automation at a core laboratory
García‐Osuna, Á., Guiñón, L., Costa-Pallaruelo, M., Usero, A. M., Eduardo, B. C., Ramos, J. L., Canyelles, M., Martínez-Brú, C., & Illana, F. J. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e22096 · Cited by 6
Perrotta, P. L., Novis, D. A., Nelson, S., Blond, B. J., Stankovic, A., & Talbert, M. L. (2020) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2020-0043-cp · Cited by 5
Validation of the Six Sigma Z-score for the quality assessment of clinical laboratory timeliness
Ialongo, C., & Bernardini, S. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0642 · Cited by 4
Self-citationBang, C., Andersen, C. F., Lauridsen, K. G., Frederiksen, C. A., Schmidt, M., Jensen, T., Hornung, N., & Løfgren, B. (2021) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2021.08.024 · Cited by 4
Marzinke, M. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-815499-1.00014-4 · Cited by 3
The Cost and Quality of Laboratory Automation: A Systematic Review
Mokoginta, M., Sjaaf, A. C., & Sjaaf, A. C. (2019) · Strengthening Hospital Competitiveness to Improve Patient Satisfaction and Better Health Outcomes · doi:10.26911/the6thicph-fp.04.24 · Cited by 3
Nigatu, T., Deress, T., Mezgebu, B., & Adane, K. (2026) · Health Research Policy and Systems · doi:10.1186/s12961-026-01458-5 · Cited by 2
Managing an automated clinical laboratory: optimization challenges and opportunities
Archetti, C., Speranza, M. G., & Garrafa, E. (2019) · EURO Journal on Decision Processes · doi:10.1007/s40070-019-00097-2 · Cited by 2
La medicina di laboratorio: Gli Specialisti di domani
Sancesario, G. M., Perrone, M. A., Pellegrini, C., Ialongo, C., Aita, A., Dabla, P. K., Taie, S. F., Favresse, J., Velts-Lindh, A., D’Argenio, V., et al. (2019) · Padua Research Archive (University of Padova) · doi:10.19186/bc_2019.039 · Cited by 2
Self-citationImpact of Laboratory Turnaround Time on Clinical Decision-Making and Patient Outcomes
Alanazi, A. G. J., Hanbouli, T. M. H. A., Albarqi, A. S. M., Aldoghmani Turki Kateb, D., Rowili, N. H. O. A., Jhory, K. E. A., Bokhari, A. M. K., Alanazi, A. A., Alenezi, T. M. R., Alawidia Ahmad Issa, A., et al. (2024) · International Journal of Computational and Experimental Science and Engineering · doi:10.22399/ijcesen.4675 · Cited by 1
Ialongo, C., & Pieri, M. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0210 · Cited by 1
Self-citationMartínez-Angulo, J. R., Hernandez-Garcia, J. C., Barrón-Zambrano, J. H., Filoteo-Razo, J. D., Jáuregui-Vazquez, D., Estudillo-Ayala, J. M., Lauterio-Cruz, J. P., Pottiez, O., Rodriguez, S. S., & Rojas-Laguna, R. (2019) · Novel Optical Systems, Methods, and Applications · doi:10.1117/12.2529678 · Cited by 1
Corrective Steps in a Total Laboratory Automation: Experience of a University Laboratory
Yıldız, R., & Ulman, C. (2023) · Journal of Turkish Clinical Biochemistry · doi:10.56615/tkbd.2023.17 · Cited by 1
Mobile phone infrastructure provides evidence of improved HIV viral load monitoring in Malawi
Haggard, R. A., Mwase, C., Klyn, B., Metz, L., Smith, T. R., Cooper, H. L. F., Chiwandira, B., Chewere, L., & Green, D. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001094 · Cited by 1
MONITORING OF TURNAROUND TIME IN DIAGNOSING CORONAVIRUS DISEASE-19 SAMPLES: NEED OF THE HOUR
Anupriya, A., Edwin, D., Lalithambigai, J., & Prabhusaran, N. (2021) · Asian Journal of Pharmaceutical and Clinical Research · doi:10.22159/ajpcr.2021.v14i9.42342
Sample volume management: the role of the clinical laboratory in minimizing diagnostic blood loss
Šimundić, A.-M., Jovičić, S. Ž., Cornes, M. P., Guillon, A., Günaydın, S., Lippi, G., Mandal, S., Plebani, M., & Wiencek, J. R. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2026-1125
Total Laboratory Automation: Transforming the Landscape of Clinical Diagnostics
Dwivedi, T., Gajendra, S., & Gupta, R. (2026) · Indian Journal of Hematology and Blood Transfusion · doi:10.1007/s12288-026-02467-8
“Improving Laboratory Operations and Patient Care through Total Laboratory Automation”
Kelkar, A. J., & Patil, V. S. (2026) · International Journal of Research and Innovation in Applied Science · doi:10.51584/ijrias.2026.11010071
Güven, B., & Can, M. (2026) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2025.83723
Strategies for Improving Laboratory Turnaround Times in Internal Medicine
al., R. S. S. J. E. (2023) · Letters in High Energy Physics
Radhakrishnan, A. (2026) · SBS Journal of Applied Business Research
Total automation of medical biology laboratories
Benghezel, H., & Sadelaoud, M. (2024) · Batna Journal of Medical Sciences (BJMS) · doi:10.48087/bjmsra.2024.11106
da Costa, F. M. N. M. (2025) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Wang, M., & Ming, L. (2020) · Journal of Laboratory Medicine · doi:10.1515/labmed-2020-0075
Vũ, M. T., & Nguyễn, T. T. (2023) · Tạp chí Y học Việt Nam · doi:10.51298/vmj.v527i2.5924
Arbiol Roca, A., & Dot-Bach, D. (2018) · RACO (Revistes Catalanes amb Accés Obert) (Consorci de Serveis Universitaris de Catalunya)
Metadata
- Authors
- Ialongo, C., Porzio, O., Giambini, I., & Bernardini, S.
- Affiliations
- University of Rome Tor Vergata (IT)
- Corresponding author
- Ialongo, Cristiano
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2016-06
- Volume
- 21
- Issue
- 3
- Pages
- 451-458
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W2010183570
- Cited by
- 42
- References
- 30
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 8 · 2018: 2 · 2017: 4 · 2016: 3
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 2130 d)
- Locations
- SLAS TECHNOLOGY (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Cineca Institutional Research Information System (Tor Vergata University) (submittedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Keywords
- core laboratory, turnaround time, cardiac troponin I, emergency department, laboratory efficiency, process management
- MeSH terms
- Diagnostic Tests, Routine, Humans, Myocardial Infarction, Retrospective Studies, Time Factors, Troponin I, Clinical Laboratory Techniques, Automation, Laboratory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.