The DOI matches its Crossref record.
Retardation of immunofluorescence fading during microscopy.
Abstract
Polyvinyl alcohol (PVA) mounting medium containing paraphenylenediamine (PPD), n-propyl gallate (NPG), or 1,4-diazobicyclo(2,2,2)-octane (DABCO) was compared with PVA alone or buffered glycerol with regard to capacity for preservation of immunofluorescence preparations. The results were based on staining of an artificial substrate with homogeneous antigen distribution followed by microphotometric determination of the initial light emission from bound fluorescein isothiocyanate (FITC)-labeled antibody and the subsequent fluorescence fading during 3-min exposure to blue excitation light. At a concentration of 0.2-2.0 g/liter and 6 g/liter, respectively, PPD and NPG were shown to effectively retard fluorescence fading without notably decreasing the initial emission intensity; two requisites were that the modified PVA used must be rather fresh and that the mounted preparations be examined within a few days. Although addition of DABCO (6 g/liter) afforded a mounting medium that tolerated storage before use better, but both PPD and NPG were more advantageous in practice. The retarding effect of PPD on fading of FITC emission was confirmed by performance testing on human tissue sections. Remounting in PVA alone is recommended for prolonged storage of sections that have been mounted in PVA modified with one of the above-mentioned compounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Caveolin, a protein component of caveolae membrane coats
Rothberg, K. G., Heuser, J. E., Donzell, W. C., Ying, Y.-S., Glenney, J. R., & Anderson, R. G. W. (1992) · Cell · doi:10.1016/0092-8674(92)90143-z · Cited by 2,258
Brundrett, M. C., Enstone, D. E., & Peterson, C. A. (1988) · Protoplasma · doi:10.1007/bf01405922 · Cited by 442
Misson, J.-P., Edwards, M. A., Yamamoto, M., & Caviness, V. S. (1988) · Developmental Brain Research · doi:10.1016/0165-3806(88)90121-6 · Cited by 422
DNA Staining for Fluorescence and Laser Confocal Microscopy
Suzuki, T., Fujikura, K., Higashiyama, T., & Takata, K. (1997) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549704500107 · Cited by 344
Dale, I., Brandtzaeg, P., Fagerhol, M. K., & Scott, H. (1985) · American Journal of Clinical Pathology · doi:10.1093/ajcp/84.1.24 · Cited by 177
Metadata
- Authors
- Valnes, K., & Brandtzaeg, P.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 1985-08
- Volume
- 33
- Issue
- 8
- Pages
- 755-761
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2051304964
- Cited by
- 187
- References
- 0
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Retardation of immunofluorescence fading during microscopy. https://app.cochat.ai/papers/10.1177/33.8.3926864
- The paper
- Valnes, K., & Brandtzaeg, P. (1985). Retardation of immunofluorescence fading during microscopy. Journal of Histochemistry & Cytochemistry. https://doi.org/10.1177/33.8.3926864
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.