Cited by 102

The DOI matches its Crossref record.

Labeling of peroxisomes with green fluorescent protein in living P. pastoris cells.

Monosov, E Z, Wenzel, T J, Lüers, G H, Heyman, J A, Subramani, S·1996·Journal of Histochemistry & Cytochemistry

Abstract

We exploited the light-activated fluorescent properties of the green fluorescent protein (GFP) of the jellyfish Aequorea victoria for studies on the peroxisomal sorting of polypeptides. GFP and GFP-SKL (containing a C-terminal, tripeptide peroxisomal targeting signal, SKL) were expressed from a methanol-inducible, alcohol oxidase (AOX1) promoter in the methylotrophic yeast Pichia pastoris. GFP was cytosolic, whereas the GFP-SKL fusion protein was targeted to peroxisomes, as demonstrated by biochemical fractionation of organelles on Nycodenz gradients. Neither GFP nor GFP-SKL affected the viability of yeast cells but both were fluorescent on excitation with 395-nm UV light. The subcellular locations of GFP and GFP-SKL in living yeast cells were monitored by fluorescence microscopy and their fluorescence was coupled to photo-oxidation of diaminobenzidine (DAB), resulting in the deposition of electron-dense oxidized DAB at intracellular locations of GFP derivatives. This photooxidation procedure permitted facile ultrastructural localization of GFP in cells by electron microscopy, and provided further evidence that GFP produced in P. pastoris is cytosolic, whereas GFP-SKL is peroxisomal. The GFP-SKL fusion protein is therefore a versatile reporter for the peroxisomal compartment, with many applications for studies involving peroxisomal import and biogenesis.

Overview

Integrity signals

Registry

Crossref · 10.1177/44.6.8666743

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cited by

Sorted by citations

Metadata

Authors
Monosov, E. Z., Wenzel, T. J., Lüers, G. H., Heyman, J. A., & Subramani, S.
Venue
Journal of Histochemistry & Cytochemistry
Published
1996-06
Volume
44
Issue
6
Pages
581-589
ISSN
  • 0022-1554
  • 1551-5044
Cited by
102
References
0
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review