A neural-network-based detection of epilepsy
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Diagnosis of epilepsy is primarily based on scalp-recorded electroencephalograms (EEG). Unfortunately the long-term recordings obtained from 'ambulatory recording systems' contain EEG data of up to one week duration, which has introduced new problems for clinical analysis. Traditional methods, where the entire EEG is reviewed by a trained professional, are very time-consuming when applied to recordings of this length. Therefore, several automated diagnostic aid approaches were proposed in recent years, in order to reduce expert effort in analyzing lengthy recordings. The most promising approaches to automated diagnosis are based on neural networks. This paper describes a method for automated detection of epileptic seizures from EEG signals using a multistage nonlinear pre-processing filter in combination with a diagnostic (LAMSTAR) Artificial Neural Network (ANN). Pre-processing via multistage nonlinear filtering, LAMSTAR input preparation, ANN training and system performance (1.6% miss rate, 97.2% overall accuracy when considering both false-alarms and 'misses') are discussed and are shown to compare favorably with earlier approaches presented in recent literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Review of methods for solving the EEG inverse problem
Pascual-Marqui, R. D. (1999) · Cited by 784
Automatic recognition of epileptic seizures in the EEG
Gotman, J. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90038-4 · Cited by 674
Detection of Seizure Activity in EEG by an Artificial Neural Network: A Preliminary Study
Pradhan, N., Puthusserypady, S. K., & Arunodaya, G. R. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0022 · Cited by 143
An Adaptive Structure Neural Networks with Application to EEG Automatic Seizure Detection
Weng, W., & Khorasani, K. (1996) · Neural Networks · doi:10.1016/0893-6080(96)00032-9 · Cited by 107
Classification of Electroencephalogram using Artificial Neural Networks
Tsoi, A. C., So, D., & Sergejew, A. A. (1993) · Cited by 54
Cited by
EEG signal classification using PCA, ICA, LDA and support vector machines
Subasi, A., & Ismail Gursoy, M. (2010) · Expert Systems with Applications · doi:10.1016/j.eswa.2010.06.065 · Cited by 1,209
Automated EEG analysis of epilepsy: A review
Acharya, U. R., Vinitha Sree, S., Swapna, G., Martis, R. J., & Suri, J. S. (2013) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.02.014 · Cited by 837
Epileptic Seizure Detection in EEGs Using Time–Frequency Analysis
Tzallas, A. T., Tsipouras, M. G., & Fotiadis, D. I. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2017939 · Cited by 744
Polat, K., & Güneş, S. (2007) · Applied Mathematics and Computation · doi:10.1016/j.amc.2006.09.022 · Cited by 666
Automated diagnosis of epileptic EEG using entropies
Acharya, U. R., Molinari, F., Sree, S. V., Chattopadhyay, S., Ng, K.-H., & Suri, J. S. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.07.007 · Cited by 626
Metadata
- Authors
- Nigam, V. P., & Graupe, D.
- Venue
- Neurological Research
- Publisher
- Informa UK Limited
- Published
- 2004-01
- Volume
- 26
- Issue
- 1
- Pages
- 55-60
- ISSN
- 0161-6412 (ISSN-L)
- 1743-1328
- OpenAlex
- W2000548777
- Cited by
- 350
- References
- 6
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.