CoChat

Preparation of TEM samples by focused ion beam (FIB) techniques: applications to the study of clays and phyllosilicates in meteorites

Lee, M. R., Bland, P. A., Graham, G. · 2003 · Mineralogical Magazine
Cited by 95

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Transmission electron microscope samples were prepared of ALH 78045 and ALH 88045, two clay-and phyllosilicate-bearing Antarctic meteorites, using argon ion milling and focused ion beam (FIB) techniques. ALH 78045 contains clay- and phyllosilicate-filled veins that have formed by terrestrial weathering of olivine, orthopyroxene and metal. Very narrow (∼10 nm) intragranular clay-filled veins could be observed in the TEM samples prepared by argon ion milling, whereas differential thinning and lack of precision in the location of the electron-transparent areas hindered the study of wider (5 — 15 μm) phyllosilicate-filled intergranular veins. Using the FIB instrument, electron-transparent slices were cut from specific parts of the wider veins and lifted out for TEM study. Results show that these veins are occluded by cronstedtite, a mixed-valence Fe-rich phyllosilicate. This discovery shows that silicates can be both dissolved and precipitated during terrestrial weathering within the Antarctic ice. ALH 88045 is one of a small number of known CM1 carbonaceous chondrites. This meteorite is largely composed of flattened ellipsoidal aggregates of serpentine-group phyllosilicates. To determine the mineralogy and texture of phyllosilicates within specific aggregates, TEM samples were prepared by trenching into the cut edge of a sample using the FIB instrument. Results show that Mg-rich aggregates are composed of lath-shaped serpentine crystals with a ∼0.73 nm basal spacing, which is typical of the products of low temperature aqueous alteration within asteroidal parent bodies. Results of this work demonstrate that the FIB has enormous potential in a number of areas of Earth and planetary science.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1180/0026461036730119

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 23

  1. Giannuzzi, 1999, Electron microscopy sample preparation for the biological and physical sciences using focused ion beams., Journal of Process Analytical Chemistry,, 4, 162
  2. 10.1111/j.1945-5100.1990.tb01004.x · DOI · Paper page
  3. Graham, 2002, In situ sectioning and analysis of cosmic dust using Focused Ion Beam microscopy, Meteoritics and Planetary Science,, 37, 56
  4. 10.1016/S0016-7037(98)00199-9 · doi:10.1016/s0016-7037(98)00199-9
  5. Overwijk, 1993, Novel scheme for the preparation of transmission electron microscopy specimens with the focused ion beam., Journal of Vacuum Science Technology,, 11
  6. Stroud, 2002, Transmission electron microscopy of a presolar corundum., Meteoritics and Planetary Sciences Supplement,,, 37, A137
  7. 10.1180/minmag.1981.044.335.19 · doi:10.1180/minmag.1981.044.335.19
  8. Giannuzzi, 1998, Advances in the FIB lift-out technique for TEM specimen preparation: HRTEM lattice imaging., Microstructural Science,, 26, 249
  9. 10.1016/S0016-7037(03)00486-1 · DOI
  10. 10.1016/0016-7037(91)90400-Y · DOI
  11. Barber, 1999, Development of ion-beam milling as a major tool for electron microscopy., Microscopy and Analysis,, 36, 5
  12. Hendricks, 1939, Random structures of layer minerals as illustrated by cronstedtite. Possible iron content of kaolin., American Mineralogist,, 24, 529
  13. 10.1007/BF01089843 · DOI · Paper page
  14. 10.1016/0012-821X(89)90029-0 · doi:10.1016/0012-821x(89)90029-0
  15. 10.2138/am-2001-8-917 · doi:10.2138/am-2001-8-917
  16. 10.1126/science.242.4877.417 · DOI · Paper page
  17. Stroud, 2000, A precise new method of microsampling chondritic material for transmission electron microscope analysis: preliminary application to calcium- aluminium-rich inclusions and associated matrix material in the Vigarano CV3 meteorite, Meteoritics and Planetary Sciences Supplement,, 35, 153
  18. 10.1007/PL00020250 · doi:10.1007/pl00020250
  19. 10.1016/0016-7037(81)90120-4 · DOI · Paper page
  20. Roberts, 2001, Advanced techniques in TEM specimen preparation, 336
  21. 10.1016/0016-7037(86)90076-1 · DOI
  22. Newman, 1987, Chemistry of Clays and Clay Minerals, 6, 1
  23. 10.1111/j.1945-5100.2000.tb01523.x · DOI

Metadata

Authors
Lee, M. R., Bland, P. A., & Graham, G.
Venue
Mineralogical Magazine
Published
2003-06
Volume
67
Issue
3
Pages
581-592
ISSN
  • 0026-461X
  • 1471-8022
Cited by
95
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.