CoChat

Validation and Preclinical Correlation of a New Sandwich ELISA for Measuring Murine Hepcidin.

Hod, Eldad A., Francis, Richard O., Spitalnik, Steven L., Winters, Aaron, Cooke, Keegan S, Sasu, Barbra J · 2012 · Blood
Cited by 6

The DOI matches its Crossref record.

Abstract

Abstract 2100 Although enzyme-linked immunosorbent assays (ELISA) exist for measuring human hepcidin, no commercially available antibodies to mouse hepcidin are validated for this purpose. Thus, we developed an ELISA to measure mouse hepcidin using low plasma volumes to allow for repeat testing of individual mice over time. To this end, human hepcidin knock-in mice (Hep2 mice) were used to generate a panel of anti mouse hepcidin antibodies. A sandwich ELISA using these antibodies was validated. Pooled plasma from iron-deficient (combining diet and phlebotomy), iron-replete, and inflamed (injecting sub-clinical amounts of lipopolysaccharide) FVB mice was used to prepare frozen aliquots of low, medium, and high reagent control plasma. These samples were tested on 5 different days (n=8 wells/sample/day). Mean hepcidin levels for the high, medium, and low reagent were 791, 504, and 117 ng/mL, respectively. The intra-assay coefficient of variation (CV) was 10, 4.5, and 15.6% for the high, medium, and low samples, respectively. Inter-assay CV was 4.7, 4.0, and 11.1% for the high, medium, and low samples, respectively. Analytical sensitivity was 0.7 ng/mL and the assay was linear (Pearson r=0.99) to 500 ng/mL at a 1:100 dilution of sample to blocking buffer (i.e. only 1 uL of sample needed per test). With 20 plasma samples spanning the range of expected hepcidin levels, there was high correlation between hepcidin determined by ELISA and the sum of hepcidin-1 and hepcidin-2 by time-of-flight mass spectrometry (Pearson r = 0.99; P<0.0001). Stability was analyzed using samples from repeated freeze-thaw cycles at −80°C or from incubation at 4°C. Each freeze-thaw cycle induced up to a 15% loss in hepcidin. Overnight refrigeration led to a 31%, 21%, and 4% decrease in hepcidin for the high, medium, and low samples, respectively. Severe hemolysis (i.e. 8 g/dL hemoglobin) caused interference, decreasing apparent hepcidin levels up to 52%; mild hemolysis (0.1 g/dL hemoglobin) decreased hepcidin levels up to 15%. To provide clinical correlation in mouse models, we used cohorts (n=5/group) of C57BL/6 females with differing iron status: Iron deficient: weanling mice on a low iron diet (0–5 ppm FeSO4; AIN diet) for 8 weeksIron-replete: weanling mice on a normal iron diet (45 ppm FeSO4; AIN diet) for 8 weeksIron-overload: mice received weekly iron-dextran injections (5 mg for 7 weeks)Transfusional iron-overload: mice received weekly syngeneic RBC transfusions (1 unit for 7 weeks) Hepcidin mirrored ferritin levels and total liver iron measured at necropsy (see Table). To test whether this ELISA can track hepcidin during infection, and whether iron status affects this response, iron-deficient or -replete mice (n=10/group) were inoculated with 1000 colony forming units of Salmonella typhimurium and blood samples obtained pre-infection and 1–7 days post-infection to measure hepcidin and interleukin (IL)-6. Pre-infection, iron-deficient mice had significantly lower hepcidin levels than iron-replete mice (<0.7 vs. 136 ± 56 ng/mL, mean ± sd). On Day 7 post-infection, IL-6 was much higher in surviving iron-deficient mice (up to >2000 pg/mL) than in iron-replete mice (207 ± 70 pg/mL). Despite dramatic increases in IL-6, hepcidin increased less in iron-deficient mice (260 ± 132 ng/mL) than in iron-replete mice (636 ± 273 ng/mL). Thus, despite a stronger inflammatory stimulus, hepcidin levels are muted in iron-deficient animals. In conclusion, this validated ELISA is a new tool that can be used to study iron regulation in mice. Liver iron (μg) Ferritin (ng/mL) Hepcidin (ng/mL) Iron replete 62 ± 10 849 ± 100 204 ± 32 Iron deficient 31 ± 5 387 ± 114 2.4 ± 1 Iron overload (Fe-Dextran) 11531 ± 1163 109912 ± 11872 633 ± 54 Iron overload (Transfusion) 352 ± 1 3302 ± 872 323 ± 64 Data presented as mean ± sd. Disclosures: Winters: Amgen, Inc.: Employment. Cooke:Amgen, Inc.: Employment. Sasu:Amgen, Inc.: Employment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v120.21.2100.2100

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 6

Metadata

Authors
Hod, E. A., Francis, R. O., Spitalnik, S. L., Winters, A., Cooke, K. S., & Sasu, B. J.
Venue
Blood
Published
2012-11-16
Volume
120
Issue
21
Pages
2100-2100
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W2577047849
Cited by
6
References
0
FWCI
0.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation and Preclinical Correlation of a New Sandwich ELISA for Measuring Murine Hepcidin. https://app.cochat.ai/papers/10.1182/blood.v120.21.2100.2100
The paper
Hod, E. A., Francis, R. O., Spitalnik, S. L., Winters, A., Cooke, K. S., & Sasu, B. J. (2012). Validation and Preclinical Correlation of a New Sandwich ELISA for Measuring Murine Hepcidin. Blood. https://doi.org/10.1182/blood.v120.21.2100.2100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.