Abstract

BACKGROUND: There is need for an artificial oxygen (O2) carrier for use when: stored blood is unavailable or undesirable. To date, efforts to develop hemoglobin (Hb) based oxygen carriers (HBOCs) have failed, because of design flaws which do not preserve physiologic interactions of Hb with: O2 (they capture O2 in lungs, but do not release O2 effectively to tissue) and nitric oxide (NO) (they trap NO, causing vasoconstriction). EM design surmounts these weaknesses by: encapsulating Hb, controlling O2 capture/release with a novel 2,3-DPG shuttle and attenuating NO uptake through shell properties. METHODS: The EM prototype and its lyophilized form were analyzed: (1) structurally (dynamic light scattering (DLS), transmission electron microscopy (TEM) and atomic force microscopy (AFM)), as well as for: (2) payload retention (Drabkin), (3) biocompatibility (ex vivo complement activation), (4) O2 affinity (p50, Hill n, Adair), (5) rheology (cone and plate viscometer in rabbit plasma), (6) NO consumption (chemiluminescence), (7) pharmacokinetic (PK) profile (tracking 99mTc-labeled EM in rats), and (8) in vivo O2 delivery (two rodent models: hemorrhagic shock [rats, instrumented for tissue pO2] and hemodilution [bioluminescent HIF-1α reporter mice]). RESULTS: EM was structurally stable (size: 175±10 nm; polydispersity: 0.26±0.0 by DLS, confirmed by TEM and AFM; zeta potential: 12±2 mV). After 3 months storage, we observed nominal change (<10%) in size, zeta potential, or polydispersity. CH50 (complement activation) results were indistinguishable from negative controls and we observed no impact on plasma viscosity (1:10 and 1:5 dilution). p50 was calculated to be 21.46±2.75 Torr (control RBC p50: 23.63±1.84); EM Hill & Adair also similar to control RBC. Two compartment PK modeling in rats resulted in good fit, with distribution t1/2=26.2±3.6 min and elimination t1/2=300±12 min (R2>0.96); which is likely to translate to a t1/2 in humans of ~ 3h. EM NO sequestration varied as a function of shell crosslinking and was below the rate observed for RBCs. In our hemorrhagic shock model in fully instrumented SD Rats (400g), 40% blood volume was removed; animals were then resuscitated with an equal volume of EM (N=6) or normal saline (N=6). EM was suspended at 40 wt/vol%, [Hb]=4mM. EM infusion rapidly stabilized hemodynamics. During the 1st hour, we observed resolution of both lactic acidosis (3.2±1.5 v 8.2±2.1 mM) [for EM and NS, respectively, throughout] and elevated AV O2 difference (24±11 v 67±23%) as well as improved brain pO2 (30.5±1.4 v 17.2±1.3 Torr); p<0.05, RMANOVA, for all. Hemodilution model:Un-instrumented, HIF-1α (ODD) luciferase mice underwent hemodilution (70% v/v) with pentastarch, fresh blood (autotransfusion controls), or EM [N=6, all groups];Hb target nadir was reached (5 mg/dL). To detect whole body luciferase expression, D-luciferin (50 mg/kg, IP) was injected, then serial images were obtained (IVIS, Living Image). HIF-luc radiance was significantly higher in the HES group than in autotransfusion and EM groups, which did not differ (p<0.01, RMANOVA). CONCLUSIONS: The ErythroMer prototype has passed rigorous initial ex vivo and in vivo "proof of concept" testing and bench testing, which suggests this design surmounts prior challenges (by HBOCs) in emulating normal RBC physiologic interactions with O2 and NO. In models of major bleeding/anemia, EM reconstitutes normal hemodynamics and O2 delivery, observed at the system, tissue, and cellular level. EM potential for extended ambient dry storage has significant implications for portability and use. Next steps include formulation scaling, detailed study of pharmacokinetics, biodistribution and safety, as well as evaluation in large animal models of hemorrhagic shock. Disclosures: Pan: KaloCyte, Inc.: Equity Ownership; Children's Discovery Institute: Research Funding; National Institutes of Health: Research Funding. Spinella:KaloCyte, Inc.: Equity Ownership; Children's Discovery Institute: Research Funding; National Institutes of Health: Research Funding. Hare:Children's Discovery Institute: Research Funding. Lanza:KaloCyte, Inc.: Membership on an entity's Board of Directors or advisory committees; National Institutes of Health: Research Funding. Doctor:KaloCyte, Inc.: Equity Ownership; Children's Discovery Institute: Research Funding; National Institutes of Health: Research Funding.

Overview

Integrity signals

Registry

Crossref · 10.1182/blood.v128.22.1027.1027

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Still being checked.

Cited by

Sorted by citations

See all 43

Metadata

Authors
Pan, D., Rogers, S., Misra, S., Vulugundam, G., Gazdzinski, L., Tsui, A., Mistry, N., Said, A., Spinella, P., Hare, G., Lanza, G., & Doctor, A.
Affiliations
  • University of Illinois Urbana-Champaign (US)
  • Washington University in St. Louis (US)
  • Li Ka Shing Knowledge Institute, Toronto, Canada
Corresponding author
  • Pan, Dipanjan
  • Rogers, Stephen
  • Misra, Santosh
  • Vulugundam, Gururaja
  • Gazdzinski, Lisa
  • Tsui, Albert
  • Mistry, Nikhil
  • Said, Ahmed
  • Spinella, Philip
  • Lanza, Greg
  • Doctor, Allan
Venue
Blood
Published
2016-12-02
Volume
128
Issue
22
Pages
1027-1027
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W2979962503
Cited by
43
References
0
Citations by year
2026: 6 · 2025: 4 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 12 · 2020: 6 · 2019: 6 · 2017: 1
FWCI
1.20
Type
journal article
Language
en
Open access
closed
Locations
Blood (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Hemoglobin structure and function
  • Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
  • Health Sciences › Medicine › Hematology › Blood transfusion and management
Keywords
artificial red blood cells, oxygen carriers, hemoglobin encapsulation, nitric oxide scavenging, oxygen affinity, complement activation, biocompatibility, pharmacokinetics, hemorrhagic shock, hemodilution, tissue oxygenation, hemoglobin-based oxygen carriers, technetium-99m

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review