Kinetics of intravenously administered heparin in normal humans
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Heparin of five commercially available brands was used to study the disappearance of heparin anticoagulant activity in normal humans. The drug was administered intravenously by bolus injection and by continuous infusion. Heparin anticoagulant activity was determined by two assays: a diluted activated partial thromboplastin time (APTT) and an assay based on inactivation of bovine factor Xa, using a clotting system. After a bolus injection, the data fitted neither single exponential nor zero-order clearance. In semilogarithmic plots, heparin anticoagulant activity disappeared according to a slightly convex curve almost always preceded by a rapid initial loss of heparin anticoagulant activity. This disappearance profile was observed with all heparin regardless of the brand or assay system. Heparin anticoagulant activity estimated by the APTT disappeared faster than heparin anticoagulant activity estimated by the anti-Xa activity in the first phase. As expected, higher anticoagulant levels with the anti-Xa assay than with the APTT were also found on continuous infusion in normals as well as in patients treated for deep vein thrombosis or pulmonary embolism. The experimental data suggested a model based on the combination of a saturable and a linear clearance mechanism. These experimental data provide reliable guidelines for adjustment of the dose of heparin in single patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andersson, L.-O., Barrowcliffe, T. W., Holmer, E., Johnson, E. A., & Sims, G. E. C. (1976) · Thrombosis Research · doi:10.1016/0049-3848(76)90105-5 · Cited by 457
Plasma heparin: a unique, practical, submicrogram-sensitive assay.
Yin, E. T., Wessler, S., & Butler, J. V. (1973) · PubMed · Cited by 253
Binding of heparin on the surface of cultured human endothelial cells
Glimelius, B., Busch, C., & Höök, M. (1978) · Thrombosis Research · doi:10.1016/0049-3848(78)90271-2 · Cited by 233
The rate of decline of diphenylhydantoin in human plasma
Arnold, K., & Gerber, N. (1970) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt1970111121 · Cited by 211
The Elimination from Plasma of Intravenous Heparin An Experimental Study on Dogs and Humans
Olsson, P., Lagergren, H., & Ek, S. (1963) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1963.tb17446.x · Cited by 147
Vascular sequestration of heparin
Mahadoo, J., Hiebert, L. M., & Jaques, L. B. (1978) · Thrombosis Research · doi:10.1016/0049-3848(78)90087-7 · Cited by 126
HEPARIN THERAPY IN THROMBOEMBOLIC DISEASE
Kernohan, R. J., & Todd, C. (1966) · The Lancet · doi:10.1016/s0140-6736(66)90822-1 · Cited by 125
Gerber, N., & Jg, W. (1972) · PubMed · Cited by 116
Catabolism of low-dose heparin in man
Dawes, J., & Pepper, D. S. (1979) · Thrombosis Research · doi:10.1016/0049-3848(79)90004-5 · Cited by 113
Heparin Pharmacokinetics: Increased Requirements in Pulmonary Embolism
Simon, T. L., Hyers, T. M., Gaston, J. P., & Harker, L. A. (1978) · British Journal of Haematology · doi:10.1111/j.1365-2141.1978.tb07133.x · Cited by 96
Friedman, Y., & Arsenis, C. (1974) · Biochemical Journal · doi:10.1042/bj1390699 · Cited by 55
Heparin, its chemistry, pharmacology and clinical use
Jorpes, J. E. (1962) · The American Journal of Medicine · doi:10.1016/0002-9343(62)90247-4 · Cited by 37
Increased uptake and desulphaton of heparin by mouse macrophages in the presence of polycations
Fabian, I., Bleiberg, I., & Aronson, M. (1978) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(78)90210-6 · Cited by 36
The Diagnosis and Treatment of Pulmonary Embolism
Crane, C. (1966) · Surgical Clinics of North America · doi:10.1016/s0039-6109(16)37882-3 · Cited by 15
Cited by
Hirsh, J., Warkentin, T. E., Shaughnessy, S. G., Anand, S. S., Halperin, J. L., Raschke, R., Granger, C., Ohman, E. M., & Dalen, J. E. (2001) · Chest · doi:10.1378/chest.119.1_suppl.64s · Cited by 1,580
Garcia, D. A., Baglin, T. P., Weitz, J. I., & Samama, M. M. (2012) · Chest · doi:10.1378/chest.11-2291 · Cited by 1,091
Heparin and Low-Molecular-Weight Heparin
Hirsh, J., Warkentin, T. E., Raschke, R., Granger, C., Ohman, E. M., & Dalen, J. E. (1998) · Chest · doi:10.1378/chest.114.5_supplement.489s · Cited by 1,031
Heparin and Low-Molecular-Weight Heparin
Hirsh, J., & Raschke, R. (2004) · Chest · doi:10.1378/chest.126.3_suppl.188s · Cited by 971
Hirsh, J., & Levine, M. (1992) · Blood · doi:10.1182/blood.v79.1.1.bloodjournal7911 · Cited by 894
Metadata
- Authors
- de Swart, C., Nijmeyer, B., Roelofs, J., & Sixma, J.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 1982-12-01
- Volume
- 60
- Issue
- 6
- Pages
- 1251-1258
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W85615424
- Cited by
- 253
- References
- 14
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.