CoChat

Platelet metabolism during storage of platelet concentrates at 22 degrees C

Open access
Kilkson, H, Holme, S, Murphy, S · 1984 · Blood
Cited by 230

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The development of methods for storing platelet concentrates (PCs) at 22 degrees C for transfusion has been predominantly empiric, with minimal knowledge of metabolic events occurring during storage. It is known that a decrease in pH due to accelerated production of lactic acid in hypoxic conditions is a major cause for loss of platelet viability. In the current studies, we have measured metabolic parameters such as O2 and glucose consumption rates and CO2 and lactic acid production rates. We have also determined the O2 and CO2 transport capacities of various containers and the buffering capacity of plasma. The O2 consumption rate was 1.10 +/- 0.16 (SD) nmol/min/10(9) platelets. In well-oxygenated systems, lactic acid formation was 1.74 +/- 0.12 nmol/min/mL PC for PCs with a platelet count of 1 to 2 X 10(9)/mL; and 0.52 mol of glucose was consumed per 1 mol lactic acid produced. In a completely oxygen-free system, lactic acid production increased 5–8-fold. These calculations suggest that 85% of energy generation is derived through oxidative metabolism and that glucose may not be the primary substrate for this metabolism. Bicarbonate concentration, initially 22.1 +/- 1.6 mEq/L, decreased 1.41 +/- 0.18 nEq/min/mL PC for PCs with counts 1 to 2 X 10(9) platelets/mL. The loss of bicarbonate was caused by displacement by lactic acid and as a consequence of spontaneous CO2 efflux from the container. CO2 production, 2.3 +/- 0.4 nmol/min/10(9) platelets, was derived from oxygen consumption and the CO2 liberated from bicarbonate as it was consumed. A rapid fall in pH to levels below 7.0 (22 degrees C) took place when the bicarbonate concentration fell below 5 mEq/L as lactate concentrations reached 20 to 25 mmol/L. A further increase in lactate concentration from 25 mmol/L to 40 mmol/L correlated with a further fall in pH to 5.8. Thus, the ultimate storage life of a PC is determined by continuous lactate production and the fixed buffering capacity of plasma and by the glucose concentration of the PC. With knowledge of these parameters, methods for predicting pH as a function of time, platelet count, and O2 and CO2 transport capability of the container have been developed as guidelines for future work.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v64.2.406.406

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Kilkson, H., Holme, S., & Murphy, S.
Venue
Blood
Published
1984-08-01
Volume
64
Issue
2
Pages
406-414
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W13535085
Cited by
230
References
6
FWCI
2.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.