Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 756

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Detection of activated platelets in whole blood using activation- dependent monoclonal antibodies and flow cytometry

Open access
Shattil, SJ, Cunningham, M, Hoxie, JA·1987·Blood

Abstract

Platelets may become activated in a number of clinical disorders and participate in thrombus formation. We developed a direct test for activated platelets in whole blood using flow cytometry. Whole blood was incubated with either biotin-PAC1, a monoclonal antibody specific for the fibrinogen receptor on activated platelets, or biotin-S12, an antibody specific for an alpha-granule membrane protein that associates with the platelet surface during secretion. Platelet-bound antibodies were detected with streptavidin conjugated with fluorescein isothiocyanate (FITC) or phycoerythrin (PE). Platelets were differentiated from the larger erythrocytes and WBCs by their light- scatter profile. Alternatively, platelets could be identified with FITC- AP1, an antibody specific for platelet membrane glycoprotein Ib, and analyzed further for PAC1 or S12 binding with PE-streptavidin. No centrifugation or washing steps were required. With gel-filtered platelets, there was a direct correlation between ADP-induced biotin- PAC1 binding and binding determined in a conventional 125I-PAC1 binding assay (r = .99; P less than .001). Furthermore, as few as 0.8% activated platelets could be detected by flow cytometry when activated platelets were mixed with unstimulated platelets. In whole blood, unstimulated platelets demonstrated no PAC1- or S12-specific fluorescence, indicating that they did not bind these antibodies. On stimulation with agonists, however, the platelets demonstrated a dose- dependent increase in fluorescence similar to that observed for platelets in plasma or buffer. Low concentrations of ADP and epinephrine, which induce fibrinogen receptors but little secretion, stimulated near-maximal PAC1 binding but little S12 binding. On the other hand, a concentration of phorbol myristate acetate (TPA) that evokes full platelet aggregation and secretion induced maximal PAC1 and S12 binding. Activated platelets could also be analyzed in whole blood samples that had been fixed with paraformaldehyde. These studies demonstrate that activated platelets can be reliably detected in whole blood using activation-dependent monoclonal antibodies and flow cytometry. This technique may be useful to assess the degree of platelet activation and the efficacy of antiplatelet therapy in clinical disorders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v70.1.307.307

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 756

Metadata

Authors
Shattil, S., Cunningham, M., & Hoxie, J.
Venue
Blood
Published
1987-07-01
Volume
70
Issue
1
Pages
307-315
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W133668382
Cited by
756
References
1
FWCI
5.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of activated platelets in whole blood using activation- dependent monoclonal antibodies and flow cytometry. https://app.cochat.ai/papers/10.1182/blood.v70.1.307.307
The paper
Shattil, S., Cunningham, M., & Hoxie, J. (1987). Detection of activated platelets in whole blood using activation- dependent monoclonal antibodies and flow cytometry. Blood. https://doi.org/10.1182/blood.v70.1.307.307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.