CoChat

Interleukin-6-associated anemia: determination of the underlying mechanism

Open access
Atkins, MB, Kappler, K, Mier, JW, Isaacs, RE, Berkman, EM · 1995 · Blood
Cited by 64

The DOI matches its Crossref record.

Abstract

Recombinant human interleukin-6 (rhIL-6) is a pluripotent cytokine with proinflammatory, antitumor, and growth factor effects. Clinical investigations of rhIL-6 either alone as immunotherapy or as a colony- stimulating factor in conjunction with chemotherapy have shown a dose- dependent, rapid onset, and largely reversible decrease in venous hematocrit levels. In an effort to determine the mechanism for the rhIL- 6-associated anemia, we measured red blood cell volume serially in patients receiving rhIL-6 at either 30 micrograms/kg/day as a 120-hour continuous intravenous infusion (renal cell carcinoma) or 100 micrograms/kg/d intravenously over 1 hour for 5 days (melanoma) as part of two separate phase II trials. Radioisotope dilution assays with 51Cr- labeled autologous red blood cells and hemolysis screens were performed on day 1 before the initiation of therapy and on day 5 shortly before the end of therapy. In the 6 patients studied, the mean decrease in hemoglobin concentration was 1.9 +/- 0.94 g/dL. The mean decrease in the hematocrit level was 6% +/- 2% and the mean increase in total blood volume was 731 +/- 337 mL. These changes were explained by a mean decrease in red blood mass of 106 +/- 109 mL and a mean increase in plasma volume of 743 +/- 289 mL. The decrease in red blood cell mass was largely explained by phlebotomy during the hospitalization, but was not statistically significant (paired t-test, P = .06). All other changes were statistically significant (P < .05). Simple regression analysis indicated that the decrease in hematocrit level and increase in plasma volume were related (y = -1.78 - .0066X; R = -.74). Measurements of lactate dehydrogenase, bilirubin, haptoglobin, and reticulocyte counts and serial stool hemoccults did not indicate hemolysis or blood loss. We conclude that the anemia caused by IL-6 is caused by an increase in plasma volume.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v86.4.1288.bloodjournal8641288

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 64

Metadata

Authors
Atkins, M., Kappler, K., Mier, J., Isaacs, R., & Berkman, E.
Venue
Blood
Published
1995-08-15
Volume
86
Issue
4
Pages
1288-1291
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W2403639111
Cited by
64
References
0
FWCI
5.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interleukin-6-associated anemia: determination of the underlying mechanism. https://app.cochat.ai/papers/10.1182/blood.v86.4.1288.bloodjournal8641288
The paper
Atkins, M., Kappler, K., Mier, J., Isaacs, R., & Berkman, E. (1995). Interleukin-6-associated anemia: determination of the underlying mechanism. Blood. https://doi.org/10.1182/blood.v86.4.1288.bloodjournal8641288

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.