The DOI matches its Crossref record.
The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria
Abstract
We have characterized the erythrocytes, granulocytes, and platelets of 54 patients with paroxysmal nocturnal hemoglobinuria (PNH) with antibodies to glycosylphosphatidylinositol-anchored proteins (anti- CD55, anti-CD59, and anti-CD16) and flow cytometry to establish the usefulness of this technique in the diagnosis of this disorder. All patients demonstrated either completely (PNH III) or partially (PNH II) deficient red cells and granulocytes. Anti-CD59 best demonstrated PNH II red cells, which were present in 50% of the patients. The proportion of abnormal granulocytes was usually greater than the proportion of abnormal red cells; 37% of the patients had >80% abnormal granulocytes. Anti-CD55 did not delineate the erythrocyte populations as well as did anti-CD59. Either anti-CD55 or anti-CD59 could be used equally well to analyze granulocytes; anti-CD16 did not demonstrate cells of partial deficiency. Platelets could not be used for detailed analysis as the normal and abnormal populations were not well distinguished. Flow cytometry of erythrocytes using anti-CD59 or of granulocytes using either anti-CD55 or anti-CD59 provides the most accurate technique for the diagnosis of paroxysmal nocturnal hemoglobinuria; it is clearly more specific, more quantitative, and more sensitive than the tests for PNH that depend upon hemolysis by complement (the acidified serum lysis [Ham] test, the sucrose lysis test, and the complement lysis sensitivity [CLS] test).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diagnosis and management of paroxysmal nocturnal hemoglobinuria
Parker, C. (2005) · Blood · doi:10.1182/blood-2005-04-1717 · Cited by 783
Paroxysmal nocturnal hemoglobinuria
Brodsky, R. A. (2014) · Blood · doi:10.1182/blood-2014-02-522128 · Cited by 648
“PNH is a clinical diagnosis that should be confirmed with peripheral blood flow cytometry to detect the absence or severe deficiency of GPI-APs on $2 lineages.(50,51) Loss of GPI-APs is detected after staining cells with monoclonal antibodies and a reagent known as fluorescent aerolysin (FLAER).”
Flow Cytometry: Principles and Clinical Applications in Hematology
Brown, M., & Wittwer, C. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.8.1221 · Cited by 471
Paroxysmal nocturnal haemoglobinuria
Hill, A., DeZern, A. E., Kinoshita, T., & Brodsky, R. A. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.28 · Cited by 448
Borowitz, M. J., Craig, F. E., DiGiuseppe, J. A., Illingworth, A. J., Rosse, W., Sutherland, D. R., Wittwer, C. T., & Richards, S. J. (2010) · Cytometry Part B: Clinical Cytometry · doi:10.1002/cyto.b.20525 · Cited by 403
Self-citation
Metadata
- Authors
- Hall, S., & Rosse, W.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 1996-06-15
- Volume
- 87
- Issue
- 12
- Pages
- 5332-5340
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W92324768
- Cited by
- 220
- References
- 0
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria. https://app.cochat.ai/papers/10.1182/blood.v87.12.5332.bloodjournal87125332
- The paper
- Hall, S., & Rosse, W. (1996). The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria. Blood. https://doi.org/10.1182/blood.v87.12.5332.bloodjournal87125332
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.