Evidence on measures for the prevention of ventilator-associated pneumonia
Open accessThe DOI matches its Crossref record; 131 of the 131 references it cites were found in a registry or an index.
Abstract
Ventilator-associated pneumonia (VAP) continues to be an important cause of morbidity and mortality in ventilated patients. Evidence-based guidelines have been issued since 2001 by the European Task Force on ventilator-associated pneumonia, the Centers for Disease Control and Prevention, the Canadian Critical Care Society, and also by the American Thoracic Society and Infectious Diseases Society of America, which have produced a joint set of recommendations. The present review article is based on a comparison of these guidelines, together with an update of further publications in the literature. The 100,000 Lives campaign, endorsed by leading US agencies and societies, states that all ventilated patients should receive a ventilator bundle to reduce the incidence of VAP. The present review article is useful for identifying evidence-based processes that can be modified to improve patients' safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200405-644st · Cited by 5,877
Kress, J. P., Pohlman, A. S., O'Connor, M. F., & Hall, J. B. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005183422002 · Cited by 2,981
Ventilator-associated Pneumonia
Chastre, J., & Fagon, J.-Y. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.7.2105078 · Cited by 2,812
Drakulovic, M. B., Torres, A., Bauer, T. T., Nicolas, J. M., Nogué, S., & Ferrer, M. (1999) · The Lancet · doi:10.1016/s0140-6736(98)12251-1 · Cited by 1,243
Complications and consequences of endotracheal intubation and tracheotomy
Stauffer, J. L., Olson, D. E., & Petty, T. L. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90413-7 · Cited by 1,211
Incidence of and Risk Factors for Ventilator-Associated Pneumonia in Critically Ill Patients
Cook, D. J., Walter, S. D., Cook, R. J., Griffith, L. E., Guyatt, G. H., Leasa, D., Jaeschke, R. Z., & Brun-Buisson, C. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-6-199809150-00002 · Cited by 1,113
Antonelli, M., Conti, G., Rocco, M., Bufi, M., De Blasi, R. A., Vivino, G., Gasparetto, A., & Meduri, G. U. (1998) · New England Journal of Medicine · doi:10.1056/nejm199808133390703 · Cited by 1,014
Incidence, Risk, and Prognosis Factors of Nosocomial Pneumonia in Mechanically Ventilated Patients
Torres, A., Aznar, R., Gatell, J. M., Jiménez, P., González, J., Ferrer, A., Celis, R., & Rodriguez-Roisin, R. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/142.3.523 · Cited by 916
Ventilator-associated Pneumonia Caused by Potentially Drug-resistant Bacteria
TROUILLET, J.-L., CHASTRE, J., VUAGNAT, A., JOLY-GUILLOU, M.-L., COMBAUX, D., DOMBRET, M.-C., & GIBERT, C. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.2.9705064 · Cited by 885
HEYLAND, D. K., COOK, D. J., GRIFFITH, L., KEENAN, S. P., & BRUN-BUISSON, C. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9807050 · Cited by 827
Cited by
Labeau, S. O., Van de Vyver, K., Brusselaers, N., Vogelaers, D., & Blot, S. I. (2011) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(11)70127-x · Cited by 321
Self-citationGuidelines for prevention of hospital acquired infections
Patil, V., Todi, S., Myatra, S. N., & Samaddar, D. P. (2014) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.128705 · Cited by 246
“ Avoid intubation whenever possible (2B)[5-7]”
Blot, S., Koulenti, D., Dimopoulos, G., Martin, C., Komnos, A., Krueger, W. A., Spina, G., Armaganidis, A., & Rello, J. (2014) · Critical Care Medicine · doi:10.1097/01.ccm.0000435665.07446.50 · Cited by 200
“However, rather than underlying diseases, other factors such as noncompliance with evidence-based infection prevention measures (12) or severity of acute illness (24) seem to put patients at a higher risk for VAP.”
BackgroundSelf-citation
Metadata
- Authors
- Lorente, L., Blot, S., & Rello, J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2007-11-30
- Volume
- 30
- Issue
- 6
- Pages
- 1193-1207
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2001247582
- Cited by
- 166
- References
- 131
- FWCI
- 8.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence on measures for the prevention of ventilator-associated pneumonia. https://app.cochat.ai/papers/10.1183/09031936.00048507
- The paper
- Lorente, L., Blot, S., & Rello, J. (2007). Evidence on measures for the prevention of ventilator-associated pneumonia. European Respiratory Journal. https://doi.org/10.1183/09031936.00048507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.