Cited by 43Obstructive Sleep Apnea ResearchNon-Invasive Vital Sign MonitoringSleep and related disorders

Validation of a single-channel airflow monitor for screening of sleep-disordered breathing

Open access
Nakano, H., Tanigawa, T., Ohnishi, Y., Uemori, H., Senzaki, K., Furukawa, T., Nishima, S.·2008·European Respiratory Journal

Abstract

A simple screening method for sleep-disordered breathing (SDB) is desirable for primary care practices. In the present study, a simple monitor, which utilises a new type of flow sensor and a novel algorithm, was prospectively validated. Home recording for 2 nights with the monitor only, followed by in-laboratory recording with the monitor together with polysomnography, were carried out in consecutive patients (n = 100) suspected of SDB. A subjective sleep log was also recorded. The signal was analysed using power spectral analysis, which yielded the flow respiratory disturbance index (flow-RDI). There was no recording failure at home. The reproducibility of the flow-RDI between the 2 nights at home was high (intraclass correlation coefficient = 0.92). The sensitivity and specificity of the in-laboratory flow-RDI to diagnose SDB were 0.96 and 0.82, 0.91 and 0.82, and 0.89 and 0.96, for apnoea/hypopnoea index (AHI) ≥5, ≥15 and ≥30 events·h−1, respectively. The diagnostic ability in low-severity subgroups (female, normal weight, AHI <15 events·h−1) was almost comparable to that in the entire group. Excluding subjective waking time on the sleep log from the recording time had no significant effect on the flow-RDI. The single-channel monitor is considered feasible for ambulatory sleep disordered breathing monitoring because of its easy applicability, high reproducibility and relatively high agreement with polysomnography results.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00130907

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 22

  1. Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med 1993; 328: 1230-1235.
  2. McNicholas WT, Bonsignore MR, Management Committee of EU COST ACTION B26., Sleep apnoea as an indepen- dent risk factor for cardiovascular disease: current evi- dence, basic mechanisms and research priorities. Eur Respir J 2007; 29: 156-178.
  3. A joint project sponsored by the American Academy of Sleep Medicine, the American Thoracic Society, and the American College of Chest Physicians. Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults. Sleep 2003; 26: 907-913.
  4. Verse T, Pirsig W, Junge-Hu ¨lsing B, Kroker B. Validation of the POLY-MESAM seven-channel ambulatory recording unit. Chest 2000; 117: 1613-1618.
  5. Parra O, Garcı ´a-Esclasans N, Montserrat JM, et al. Should patients with sleep apnoea/hypopnoea syndrome be diagnosed and managed on the basis of home sleep studies? Eur Respir J 1997; 10: 1720-1724.
  6. Dingli K, Coleman EL, Vennelle M, et al. Evaluation of a portable device for diagnosing the sleep apnoea/hypop- noea syndrome. Eur Respir J 2003; 21: 253-259.
  7. Golpe R, Jime ´nez A, Carpizo R. Home sleep studies in the assessment of sleep apnea/hypopnea syndrome. Chest 2002; 122: 1156-1161.
  8. Shochat T, Hadas N, Kerkhofs M, et al. The SleepStrip: an apnoea screener for the early detection of sleep apnoea syndrome. Eur Respir J 2002; 19: 121-126.
  9. Erman MK, Stewart D, Einhorn D, Gordon N, Casal E. Validation of the ApneaLink for screening of sleep apnea: a novel and simple single-channel recording device. J Clin Sleep Med 2007; 3: 387-392.
  10. de Almeida FR, Ayas NT, Otsuka R, et al. Nasal pressure recordings to detect obstructive sleep apnea. Sleep Breath 2006; 10: 62-69.
  11. Nakano H, Tanigawa T, Furukawa T, Nishima S. Automatic detection of sleep-disordered breathing from a single- channel airflow record. Eur Respir J 2007; 29: 728-736.
  12. Kushida CA, Littner MR, Morgenthaler T, et al. Practice para- meters for the indications for polysomnography and related procedures: an update for 2005. Sleep 2005; 28: 499-521.
  13. Bonnet M, Carley D, Carskadon M, et al. EEG arousals: scoring rules and examples: a preliminary report from the Sleep Disorders Atlas Task Force of the American Sleep Disorders Association. Sleep 1992; 15: 173-184.
  14. Fleiss JL. Statistical Methods for Rates and Proportions. New York, John Wiley & Sons, 2003; pp. 599-608.
  15. Va ´zquez JC, Tsai WH, Flemons WW, et al. Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnea. Thorax 2000; 55: 302-307.
  16. Gurubhagavatula I, Maislin G, Pack A. An algorithm to stratify sleep apnea risk in a sleep disorders clinic population. Am J Respir Crit Care Med 2001; 164: 1904-1909.
  17. Nakano H, Ikeda T, Hayashi M, et al. Effect of body mass index on overnight oximetry for the diagnosis of sleep apnea. Respir Med 2004; 98: 421-427.
  18. Farre R, Montserrat JM, Rotger M, Ballester E, Navajas D. Accuracy of thermistors and thermocouples as flowmea- suring devices for detecting hypopnoeas. Eur Respir J 1998; 11: 179-182.
  19. Berry RB, Koch GL, Trautz S, Wagner MH. Comparison of respiratory event detection by a polyvinylidene fluoride film airflow sensor and a pneumotachograph in sleep apnea patients. Chest 2005; 128: 1331-1338.
  20. Hans PA, Van Dongen HP, Maislin G, Mullington JM, David F, Dinges DF. The cumulative cost of additional wakefulness: dose-response effects on neurobehavioral functions and sleep physiology from chronic sleep restric- tion and total sleep deprivation. Sleep 2003; 26: 117-126.
  21. Netzer NC, Stoohs RA, Netzer CM, Clark K, Strohl KP. Using the Berlin questionnaire to identify patients at risk for the sleep apnea syndrome. Ann Intern Med 1999; 131: 485-491.
  22. Tanigawa T, Tachibana N, Yamagishi K, et al. Usual alcohol consumption and arterial oxygen desaturation during sleep. JAMA 2004; 292: 923-925.

Cited by

Sorted by citations

Authors
Nakano, H., Tanigawa, T., Ohnishi, Y., Uemori, H., Senzaki, K., Furukawa, T., & Nishima, S.
Affiliations
  • Fukuoka Hospital (JP)
  • Ehime University (JP)
  • Tenri Hospital (JP)
Venue
European Respiratory Journal
Published
2008-05-14
Volume
32
Issue
4
Pages
1060-1067
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W1970005536
Cited by
43
References
1
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 3 · 2019: 1 · 2018: 3 · 2017: 4 · 2016: 2 · 2015: 1 · 2014: 2 · 2013: 3 · 2012: 1
FWCI
1.49
Type
journal article
Language
en
Open access
Locations
  • European Respiratory Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
sleep-disordered breathing, home sleep apnea testing, flow sensors, apnea-hypopnea index, diagnostic accuracy, reproducibility, power spectrum analysis, primary care screening
MeSH terms
Adult, Algorithms, Equipment Design, Female, Humans, Male, Middle Aged, Primary Health Care, Prospective Studies, Quality of Life, Sleep, Sleep Apnea Syndromes, Reproducibility of Results, Polysomnography, Continuous Positive Airway Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review