The DOI matches its Crossref record.
Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions
Abstract
The present study prospectively evaluated the diagnostic yield and safety of electromagnetic navigation-guided bronchoscopy biopsy, for small peripheral lung lesions in patients where standard techniques were nondiagnostic. The study was conducted in a tertiary medical centre on 40 consecutive patients considered unsuitable for straightforward surgery or computed tomography (CT)-guided transthoracic needle aspiration biopsy, due to comorbidities. The lung lesion diameter was mean±sem 23.5±1.5 mm and the depth from the visceral-costal pleura was 14.9±2 mm. Navigation was facilitated by an electromagnetic tracking system which could detect a position sensor incorporated into a flexible catheter advanced through a bronchoscope. Information obtained during bronchoscopy was superimposed on previously acquired CT data. Divergence between CT data and data obtained during bronchoscopy was calculated by the system's software as a measure of navigational accuracy. All but one of the target lesions was reached and the overall diagnostic yield was 62.5% (25–40). Diagnostic yield was significantly affected by CT-to-body divergence; yield was 77.2% when estimated divergence was ≤4 mm. Three pneumothoraces occurred and chest drainage was required in one case. Electromagnetic navigation-guided bronchoscopy has the potential to improve the diagnostic yield of transbronchial biopsies without additional fluoroscopic guidance, and may be useful in the early diagnosis of lung cancer, particularly in nonoperable patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Establishing the Diagnosis of Lung Cancer
Rivera, M. P., Mehta, A. C., & Wahidi, M. M. (2013) · Chest · doi:10.1378/chest.12-2353 · Cited by 1,089
Meta-analysis of Guided Bronchoscopy for the Evaluation of the Pulmonary Nodule
Wang Memoli, J. S., Nietert, P. J., & Silvestri, G. A. (2012) · Chest · doi:10.1378/chest.11-1764 · Cited by 665
Gex, G., Pralong, J. A., Combescure, C., Seijo, L., Rochat, T., & Soccal, P. M. (2014) · Respiration · doi:10.1159/000355710 · Cited by 290
2d/3d Registration of Endoscopic Ultrasound to Ct Volume Data
Hummel, J., Figl, M., Bax, M., Bergmann, H., & Birkfellner, W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/16/006 · Cited by 47
Metadata
- Authors
- Makris, D., Scherpereel, A., Leroy, S., Bouchindhomme, B., Faivre, J.-B., Remy, J., Ramon, P., & Marquette, C.-H.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2007-03-14
- Volume
- 29
- Issue
- 6
- Pages
- 1187-1192
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2127764222
- Cited by
- 222
- References
- 0
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions. https://app.cochat.ai/papers/10.1183/09031936.00165306
- The paper
- Makris, D., Scherpereel, A., Leroy, S., Bouchindhomme, B., Faivre, J.-B., Remy, J., Ramon, P., & Marquette, C.-H. (2007). Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions. European Respiratory Journal. https://doi.org/10.1183/09031936.00165306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.