CoChat

In defence of the carbon monoxide transfer coefficient KCO(TL/VA)

Open access
Hughes, J.M.B., Pride, N.B. · 2001 · European Respiratory Journal
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The carbon monoxide transfer factor (TL,CO) is the product of the two primary measurements during breath-holding, the CO transfer coefficient (KCO) and the alveolar volume (VA).KCO is essentially the rate constant for alveolar CO uptake (Krogh's kCO), and in healthy subjects, increases when VA is reduced by submaximal inflation, or when pulmonary blood flow increases. Recently, new reference values were proposed for clinical use which included the observed VA at full inflation; this was claimed to “eliminate the need for KCO”. In this commentary, some mechanisms e.g.respiratory muscle weakness, lung resection, diffuse alveolar damage and airflow obstruction, which decrease or increase total lung capacity (TLC) are reviewed. Even when alveolar structure and function are normal, the change in KCO at a given VA varies according to the underlying pathophysiological mechanism. The advantages and disadvantages of normalizing KCO and TL,CO to predisease predicted TLC or to the patient's actual VA(using lack of expansion or loss of alveolar units models) are considered. Examination of carbon monoxide transfer coefficient and alveolar volume separately provides information on disease pathophysiology which cannot be obtained from their product, the carbon monoxide transfer factor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.01.17201680

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Diffusing capacity dependent on lung volume and age in normal subjects

    Stam, H., Hrachovina, V., Stijnen, T., & Versprille, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.6.2356 · Cited by 105 · cited 4×

    “[5] suggested that when TLC is reduced by disease, TL,CO values should be compared with reference values based on the observed VA, but they cautioned that this assumes that "the effect of decreasing lung volume by disease has the same effect on TL/VA as the voluntary reduction in lung volume in healthy volunteers".”
    BackgroundResultInfluential

Show all 1 references

Cited by

See all 111

Metadata

Authors
Hughes, J. M. B., & Pride, N. B.
Venue
European Respiratory Journal
Published
2001-02
Volume
17
Issue
2
Pages
168-174
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2099735780
Cited by
111
References
1
FWCI
2.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In defence of the carbon monoxide transfer coefficient KCO(TL/VA). https://app.cochat.ai/papers/10.1183/09031936.01.17201680
The paper
Hughes, J. M. B., & Pride, N. B. (2001). In defence of the carbon monoxide transfer coefficient KCO(TL/VA). European Respiratory Journal. https://doi.org/10.1183/09031936.01.17201680

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.