Ventricular mass index using magnetic resonance imaging accurately estimates pulmonary artery pressure
Open accessAbstract
Magnetic resonance imaging (MRI) can provide accurate anatomical measurements of the cardiac ventricles. This study investigated whether a calculated ventricular mass index (VMI) would provide an accurate means of estimating pulmonary artery pressure noninvasively, and compared the results with conventional Doppler echocardiography and invasive measurement. A total of 26 subjects referred for investigation of pulmonary hypertension were studied by MRI and echocardiography within 2 weeks of cardiac catheterisation. The correlations for mean pulmonary artery pressure were as follows: VMI (ratio of right ventricular mass over left ventricular mass) r=0.81; pulmonary artery systolic pressure (echocardiography) r=0.77. The confidence intervals for the VMI were narrower than for echocardiography. Sensitivity and specificity for pulmonary hypertension were 84 and 71% respectively for the VMI compared with 89 and 57% for echocardiography. The calculated ventricular mass index provides an accurate and practical means of estimating pulmonary artery pressure noninvasively in pulmonary hypertension and may provide a more accurate estimate than Doppler echocardiography. This may be because it reflects the right ventricular response to sustained pulmonary hypertension over a long period and is not influenced by short-term physiological variables affecting echocardiography, such as heart rate, posture, hydration status and oxygen supplementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
van Wolferen, S. A., Marcus, J. T., Boonstra, A., Marques, K. M. J., Bronzwaer, J. G. F., Spreeuwenberg, M. D., Postmus, P. E., & Vonk-Noordegraaf, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl477 · Cited by 753
Pulmonary Arterial Hypertension
McLaughlin, V. V., & McGoon, M. D. (2006) · Circulation · doi:10.1161/circulationaha.104.503540 · Cited by 664
Champion, H. C., Michelakis, E. D., & Hassoun, P. M. (2009) · Circulation · doi:10.1161/circulationaha.106.674028 · Cited by 468
The right ventricle in pulmonary hypertension
Chin, K. M., Kim, N. H. S., & Rubin, L. J. (2005) · Coronary Artery Disease · doi:10.1097/00019501-200502000-00003 · Cited by 429
Contrast enhanced-cardiovascular magnetic resonance imaging in patients with pulmonary hypertension
Blyth, K. G., Groenning, B. A., Martin, T. N., Foster, J. E., Mark, P. B., Dargie, H. J., & Peacock, A. J. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi328 · Cited by 226
Self-citation
Metadata
- Authors
- Saba, T. S., Foster, J., Cockburn, M., Cowan, M., & Peacock, A. J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2002-12
- Volume
- 20
- Issue
- 6
- Pages
- 1519-1524
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2122189467
- Cited by
- 187
- References
- 0
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventricular mass index using magnetic resonance imaging accurately estimates pulmonary artery pressure. https://app.cochat.ai/papers/10.1183/09031936.02.00014602
- The paper
- Saba, T. S., Foster, J., Cockburn, M., Cowan, M., & Peacock, A. J. (2002). Ventricular mass index using magnetic resonance imaging accurately estimates pulmonary artery pressure. European Respiratory Journal. https://doi.org/10.1183/09031936.02.00014602
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.