MRI of the pharynx and treatment efficacy of a mandibular advancement device in obstructive sleep apnoea syndrome
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
In obstructive sleep apnoea syndrome (OSAS), prosthetic mandibular advancement devices (MAD) seem to be a promising treatment alternative to conventional continuous positive airway pressure therapy. Unfortunately, while they are effective in some patients, they are ineffective in others or may even worsen OSAS. At present, it is not known whether predictors can be defined which allow for estimation of the potential effect of oral appliances on the severity of OSAS. Clinical and polysomnographical efficacy of a MAD was evaluated in 15 patients with OSAS. In addition, ultrafast magnetic resonance imaging (MRI) of the pharynx was performed in 13 of these patients at rest during transnasal shallow respiration and during performance of the Muller manoeuvre, both with and without the MAD, and the site of closure was determined. The MAD reduced the mean apnoea/hypopnoea index (AHI) from 19.8±14.5 to 7.2±7.4·h−1. Seven subjects (53.8%) had at least a 50% reduction in AHI to a value <10·h−1 with the MAD, whereas the MAD was ineffective in six patients. Five of the seven treatment responders had no significant pharyngeal obstruction during the manoeuvre with the device, while all of them had pharyngeal obstruction when not equipped with the device. Four of the six patients with treatment failure had a single velopharyngeal obstruction and two a combined obstruction of the velo‐ and glossopharynx during the Muller manoeuvre while wearing the device. The results of this study suggest that airway patency during the Muller manoeuvre while wearing a mandibular advancement device may be predictive of the success of obstructive sleep apnoea syndrome treatment with a mandibular advancement device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Horner, R., Mohiaddin, R., Lowell, D., Shea, S., Burman, E., Longmore, D., & Guz, A. (1989) · European Respiratory Journal · doi:10.1183/09031936.93.02070613 · Cited by 521 · cited 1×
“Patients with OSAS have more fat in the areas surrounding the collapsible segment of the pharynx compared to equally obese control subjects without OSAS [22].”
BackgroundSide Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome
Pépin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., & Lévy, P. (1995) · Chest · doi:10.1378/chest.107.2.375 · Cited by 422
Ferguson, K. A., Ono, T., Lowe, A. A., al-Majed, S., Love, L. L., & Fleetham, J. A. (1997) · Thorax · doi:10.1136/thx.52.4.362 · Cited by 391
Improvement of Mild Sleep-disordered Breathing with CPAP Compared with Conservative Therapy
REDLINE, S., ADAMS, N., STRAUSS, M. E., ROEBUCK, T., WINTERS, M., & ROSENBERG, C. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.3.9709042 · Cited by 240 · cited 1×
“These symptoms may compromise a patient9s ability to successfully utilise CPAP and impair compliance with this treatment [6].”
Background
Cited by
Oral Appliances for Snoring and Obstructive Sleep Apnea: A Review
Ferguson, K. A., Cartwright, R., Rogers, R., & Schmidt-Nowara, W. (2006) · Sleep · doi:10.1093/sleep/29.2.244 · Cited by 687
Oral appliances and functional orthopaedic appliances for obstructive sleep apnoea in children
Carvalho, F. R., Lentini-Oliveira, D. A., Prado, L. B., Prado, G. F., & Carvalho, L. B. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005520.pub3 · Cited by 127
Oral appliance treatment of obstructive sleep apnea: an update
Chan, A. S., & Cistulli, P. A. (2009) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0b013e3283319b12 · Cited by 103
Non–Positive Airway Pressure Modalities: Mandibular Advancement Devices/Positional Therapy
Chan, A. S. L., Lee, R. W. W., & Cistulli, P. A. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200707-104mg · Cited by 49
Randerath, W., Bauer, M., Blau, A., Fietze, I., Galetke, W., Hein, H., Maurer, J. T., Orth, M., Rasche, K., Ruhle, K.-H., et al. (2006) · Somnologie · doi:10.1111/j.1439-054x.2006.00082.x · Cited by 19
Self-citation
Metadata
- Authors
- Sanner, B. M., Heise, M., Knoben, B., Machnick, M., Laufer, U., Kikuth, R., Zidek, W., & Hellmich, B.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2002-07
- Volume
- 20
- Issue
- 1
- Pages
- 143-150
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2132135596
- Cited by
- 93
- References
- 8
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: MRI of the pharynx and treatment efficacy of a mandibular advancement device in obstructive sleep apnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.02.00268902
- The paper
- Sanner, B. M., Heise, M., Knoben, B., Machnick, M., Laufer, U., Kikuth, R., Zidek, W., & Hellmich, B. (2002). MRI of the pharynx and treatment efficacy of a mandibular advancement device in obstructive sleep apnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.02.00268902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.