CoChat

MRI of the pharynx and treatment efficacy of a mandibular advancement device in obstructive sleep apnoea syndrome

Open access
Sanner, B.M., Heise, M., Knoben, B., Machnick, M., Laufer, U., Kikuth, R., Zidek, W., Hellmich, B. · 2002 · European Respiratory Journal
Cited by 93

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

In obstructive sleep apnoea syndrome (OSAS), prosthetic mandibular advancement devices (MAD) seem to be a promising treatment alternative to conventional continuous positive airway pressure therapy. Unfortunately, while they are effective in some patients, they are ineffective in others or may even worsen OSAS. At present, it is not known whether predictors can be defined which allow for estimation of the potential effect of oral appliances on the severity of OSAS. Clinical and polysomnographical efficacy of a MAD was evaluated in 15 patients with OSAS. In addition, ultrafast magnetic resonance imaging (MRI) of the pharynx was performed in 13 of these patients at rest during transnasal shallow respiration and during performance of the Muller manoeuvre, both with and without the MAD, and the site of closure was determined. The MAD reduced the mean apnoea/hypopnoea index (AHI) from 19.8±14.5 to 7.2±7.4·h−1. Seven subjects (53.8%) had at least a 50% reduction in AHI to a value <10·h−1 with the MAD, whereas the MAD was ineffective in six patients. Five of the seven treatment responders had no significant pharyngeal obstruction during the manoeuvre with the device, while all of them had pharyngeal obstruction when not equipped with the device. Four of the six patients with treatment failure had a single velopharyngeal obstruction and two a combined obstruction of the velo‐ and glossopharynx during the Muller manoeuvre while wearing the device. The results of this study suggest that airway patency during the Muller manoeuvre while wearing a mandibular advancement device may be predictive of the success of obstructive sleep apnoea syndrome treatment with a mandibular advancement device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.02.00268902

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 93

Metadata

Authors
Sanner, B. M., Heise, M., Knoben, B., Machnick, M., Laufer, U., Kikuth, R., Zidek, W., & Hellmich, B.
Venue
European Respiratory Journal
Published
2002-07
Volume
20
Issue
1
Pages
143-150
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2132135596
Cited by
93
References
8
FWCI
1.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MRI of the pharynx and treatment efficacy of a mandibular advancement device in obstructive sleep apnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.02.00268902
The paper
Sanner, B. M., Heise, M., Knoben, B., Machnick, M., Laufer, U., Kikuth, R., Zidek, W., & Hellmich, B. (2002). MRI of the pharynx and treatment efficacy of a mandibular advancement device in obstructive sleep apnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.02.00268902

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.