Bedside methods versus dual energy X‐ray absorptiometry for body composition measurement in COPD

Open access
Steiner, M.C., Barton, R.L., Singh, S.J., Morgan, M.D.L. · 2002 · European Respiratory Journal

Abstract

The measurement of body composition is of value in the nutritional assessment of patients with chronic obstructive pulmonary disease (COPD). The purpose of the present study was to compare two bedside methods for the measurement of body composition using dual energy X‐ray absorptiometry (DEXA) as a reference method. Fat-free mass (FFM) was measured using DEXA, bioelectric impedance analysis (BIA) and skinfold anthropometry (SFA) in a cohort of 85 COPD patients accepted for pulmonary rehabilitation. Patients whose body mass index was >30 were excluded. Relative to DEXA, BIA underestimated FFM, whereas it was overestimated by SFA. There was a systematic increase in bias with mean FFM for both DEXA versus BIA and DEXA versus SFA, but this was almost eliminated when results were expressed as FFM index. Significant sex differences in the bias of BIA and SFA measurements of FFM were found. Forty-two (49.4%) patients were identified as nutritionally depleted using DEXA. Compared to DEXA, the sensitivity for detecting nutritional depletion was 86 and 74% for BIA and SFA, respectively, and the specificity 88 and 98%, respectively. There are significant intermethod differences in the measurement of body composition in chronic obstructive pulmonary disease patients. The choice of measurement method will have implications for nutritional assessment in chronic obstructive pulmonary disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.02.00279602

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 256

Metadata

Authors
Steiner, M. C., Barton, R. L., Singh, S. J., & Morgan, M. D. L.
Venue
European Respiratory Journal
Published
2002-04
Volume
19
Issue
4
Pages
626-631
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2137187223
Cited by
256
References
25
FWCI
6.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bedside methods versus dual energy X‐ray absorptiometry for body composition measurement in COPD. https://app.cochat.ai/papers/10.1183/09031936.02.00279602
The paper
Steiner, M. C., Barton, R. L., Singh, S. J., & Morgan, M. D. L. (2002). Bedside methods versus dual energy X‐ray absorptiometry for body composition measurement in COPD. European Respiratory Journal. https://doi.org/10.1183/09031936.02.00279602

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.