Effect of inhaled bronchodilators on inspiratory capacity and dyspnoea at rest in COPD
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
It has been shown that patients with chronic obstructive pulmonary disease (COPD) develop dynamic hyperinflation (DH), which contributes to dyspnoea and exercise intolerance. Formoterol, salmeterol and oxitropium have been recommended for maintenance therapy in COPD patients, but their effect on DH has only been assessed for salmeterol. The aim of the present study was to compare the acute effect of four inhaled bronchodilators (salbutamol, formoterol, salmeterol and oxitropium) and placebo on forced expiratory volume in one second, inspiratory capacity, forced vital capacity and dyspnoea in COPD patients. A cross-over, randomised, double-blind, placebo-controlled study was carried out on 20 COPD patients. Patients underwent pulmonary function testing and dyspnoea evaluation, in basal condition and 5, 15, 30, 60 and 120 min after bronchodilator or placebo administration. The results indicate that in chronic obstructive pulmonary disease patients with decreased baseline inspiratory capacity, there was a much greater increase of inspiratory capacity after bronchodilator administration, which correlated closely with the improvement of dyspnoea sensation at rest. For all bronchodilators used, inspiratory capacity reversibility should be tested at 30 min following the bronchodilator. On average, formoterol elicited the greatest increase in inspiratory capacity than the other bronchodilators used, though the difference was significant only with salmeterol and oxitropium. The potential advantage of formoterol needs to be tested in a larger patient population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'DONNELL, D. E., LAM, M., & WEBB, K. A. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.2.9901038 · Cited by 485 · cited 1×
“The improvement of IC after bronchodilator administration has been shown to predict the improvement of exertional dyspnoea and exercise tolerance in COPD patients [8, 10 ].”
BackgroundBelman, M. J., Botnick, W. C., & Shin, J. W. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.153.3.8630581 · Cited by 402 · cited 2×
“The above studies, together with other reports [8, 12, 15–18], have clearly shown that standard measurement of DFEV1 after bronchodilator administration does not uncover significant volume responses that may be more relevant in terms of bronchodilator therapy of COPD patients.”
BackgroundResultDiaz, O., Villafranca, C., Ghezzo, H., Borzone, G., Leiva, A., Milic-Emil, J., & Lisboa, C. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16b14.x · Cited by 300 · cited 3×
“In the present study, the authors stratified the patients according to reduced or normal IC, based on the observation that in patients with tidal EFL, the IC is usually reduced below 80% pred [3].”
BackgroundResultInfluentialEffect of salbutamol on dynamic hyperinflation in chronic obstructive pulmonary disease patients
Tantucci, C., Duguet, A., Similowski, T., Zelter, M., Derenne, J., & Milic-Emili, J. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12040799 · Cited by 216
Self-citation
Cited by
Casanova, C., Cote, C., de Torres, J. P., Aguirre-Jaime, A., Marin, J. M., Pinto-Plata, V., & Celli, B. R. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-867oc · Cited by 597
“The resting inspiratory capacity (IC), a reflection of end-expiratory lung volume, has been correlated with exercise capacity measured by the peak V̇o2 (11) and with carbon dioxide retention during exercise (27), and has been used to assess the effect of inhaled bronchodilator (28, 29).”
BackgroundMinimal Clinically Important Differences in COPD Lung Function
Donohue, J. F. (2005) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1081/copd-200053377 · Cited by 529
Welte, T., Miravitlles, M., Hernandez, P., Eriksson, G., Peterson, S., Polanowski, T., & Kessler, R. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200904-0492oc · Cited by 408
Hyperinflation, Dyspnea, and Exercise Intolerance in Chronic Obstructive Pulmonary Disease
O'Donnell, D. E. (2006) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200508-093do · Cited by 398
Inspiratory Capacity during Exercise: Measurement, Analysis, and Interpretation
Guenette, J. A., Chin, R. C., Cory, J. M., Webb, K. A., & O'Donnell, D. E. (2013) · Pulmonary Medicine · doi:10.1155/2013/956081 · Cited by 203
Metadata
- Authors
- Di Marco, F., Milic-Emili, J., Boveri, B., Carlucci, P., Santus, P., Casanova, F., Cazzola, M., & Centanni, S.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2002-01-01
- Volume
- 21
- Issue
- 1
- Pages
- 86-94
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2122498329
- Cited by
- 117
- References
- 4
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of inhaled bronchodilators on inspiratory capacity and dyspnoea at rest in COPD. https://app.cochat.ai/papers/10.1183/09031936.03.00020102
- The paper
- Di Marco, F., Milic-Emili, J., Boveri, B., Carlucci, P., Santus, P., Casanova, F., Cazzola, M., & Centanni, S. (2003). Effect of inhaled bronchodilators on inspiratory capacity and dyspnoea at rest in COPD. European Respiratory Journal. https://doi.org/10.1183/09031936.03.00020102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.