CoChat

Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma

Anees, W., Gannon, P.F., Huggins, V., Pantin, C.F.A., Burge, P.S. · 2004 · European Respiratory Journal
Cited by 68

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Serial peak expiratory flow records are recommended in the first-line investigation of suspected occupational asthma. The effects of sequentially reducing the numbers of working weeks, consecutive days at work and readings taken per day on diagnostic sensitivity and specificity were investigated, using good quality peak expiratory flow records from 81 workers with independently confirmed occupational asthma and 60 asthmatics without occupational exposure. Sensitivity was 81.8% for records of 4 weeks' duration and 70% for those of 2 weeks' duration (specificity 93.8 and 82.4% respectively). The sensitivity fell to 56.7% if there were only 2 consecutive workdays in each work period. Although best at 8 readings·day−1, sensitivity and specificity were acceptable with four daily readings (82.4 and 87%). The effect of defining a record as being of adequate quality if it was of ≥2.5 weeks' duration, with ≥4 readings·day−1 and ≥3 consecutive workdays in each work period, was tested in records not used in the initial data reduction process. The sensitivity and specificity respectively of adequate records were 78.1 and 91.8 versus 63.6 and 83.3% for inadequate records. Peak expiratory flow records for the diagnosis of occupational asthma should be interpreted with caution if they do not satisfy the suggested minimum data quantity criteria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.04.00027304

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 68

Metadata

Authors
Anees, W., Gannon, P. F., Huggins, V., Pantin, C. F. A., & Burge, P. S.
Venue
European Respiratory Journal
Published
2004-05
Volume
23
Issue
5
Pages
730-734
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2170707532
Cited by
68
References
1
FWCI
6.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma. https://app.cochat.ai/papers/10.1183/09031936.04.00027304
The paper
Anees, W., Gannon, P. F., Huggins, V., Pantin, C. F. A., & Burge, P. S. (2004). Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma. European Respiratory Journal. https://doi.org/10.1183/09031936.04.00027304

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.