Exercise testing in pulmonary arterial hypertension and in chronic heart failure
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Exercise capacity is reduced in pulmonary arterial hypertension and in chronic left heart failure, but it is not known whether the cardiopulmonary exercise testing profile is different in the two conditions at the same severity of functional limitation. Nineteen patients with pulmonary arterial hypertension and 19 with chronic heart failure underwent a 6‐min walk test and symptom-limited maximal incremental cycle ergometry. The patients with pulmonary arterial hypertension and chronic heart failure did not differ in New York Heart Association Functional Class (mean±sem 2.8±0.1 versus 2.8±0.2), 6‐min walking distance (395±30 versus 419±20 m), peak work-rate, oxygen consumption, ventilation and cardiac frequency. However, patients with pulmonary arterial hypertension exhibited higher dyspnoea scores (5.8±0.6 versus 3.8±0.5) higher ventilatory equivalents for carbon dioxide (58±3 versus 44±3 at the anaerobic threshold) and lower peak oxygen pulse (5.9±0.4 versus 8.7±0.5 mL·beat−1, or 53±4 versus 64±4% of the predicted value). It is concluded that the cardiopulmonary exercise testing profile in pulmonary arterial hypertension differs from that in chronic heart failure by showing more dyspnoea at comparable work-rates, related to greater reductions in ventilatory efficiency and stroke volume.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical bases of perceived exertion
BORG, G. A. V. (1982) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198205000-00012 · Cited by 16,580
Cited by
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Pulmonary Arterial Hypertension
McLaughlin, V. V., & McGoon, M. D. (2006) · Circulation · doi:10.1161/circulationaha.104.503540 · Cited by 664
Pulmonary hypertension in COPD
Chaouat, A., Naeije, R., & Weitzenblum, E. (2008) · European Respiratory Journal · doi:10.1183/09031936.00015608 · Cited by 625
Self-citationHow to assess physical activity? How to assess physical fitness?
Vanhees, L., Lefevre, J., Philippaerts, R., Martens, M., Huygens, W., Troosters, T., & Beunen, G. (2005) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/00149831-200504000-00004 · Cited by 586
Diagnosis of pulmonary hypertension
Frost, A., Badesch, D., Gibbs, J. S. R., Gopalan, D., Khanna, D., Manes, A., Oudiz, R., Satoh, T., Torres, F., & Torbicki, A. (2019) · European Respiratory Journal · doi:10.1183/13993003.01904-2018 · Cited by 479
Metadata
- Authors
- Deboeck, G., Niset, G., Lamotte, M., Vachiéry, J., & Naeije, R.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2004-05
- Volume
- 23
- Issue
- 5
- Pages
- 747-751
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2160501139
- Cited by
- 138
- References
- 1
- FWCI
- 14.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exercise testing in pulmonary arterial hypertension and in chronic heart failure. https://app.cochat.ai/papers/10.1183/09031936.04.00111904
- The paper
- Deboeck, G., Niset, G., Lamotte, M., Vachiéry, J., & Naeije, R. (2004). Exercise testing in pulmonary arterial hypertension and in chronic heart failure. European Respiratory Journal. https://doi.org/10.1183/09031936.04.00111904
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.