Home respiratory polygraphy for diagnosis of sleep-disordered breathing in heart failure
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The present study assessed the usefulness of home cardiorespiratory polygraphy as an alternative to overnight polysomnography for the diagnosis of sleep-disordered breathing in heart failure. A total of 75 patients with chronic stable heart failure due to systolic dysfunction (left ventricular ejection fraction ≤45%) underwent polysomnography at the Virgen del Rocio Hospital and cardiorespiratory polygraphy at home. The two studies were performed in random order and within 30 days. The accuracy of polygraphical findings was determined by sensitivity and specificity obtained by area under the receiver operating characteristics (ROC) curves for apnoea-hypopnoea index (AHI) thresholds of ≥5, ≥10 and ≥15 in the polysomnography. The area under the ROC curve for AHI ≥5, ≥10 and ≥15 was 0.896, 0.907 and 0.862, respectively. The diagnostic accuracy of polygraphy compared with polysomnography ranged 78.6–84%, with sensitivities of 68.4–82.5%, and specificities of 88.6–97.8% for the different AHI thresholds. Altogether, 29 patients had an AHI ≥10 (central pattern 24, obstructive pattern 5). Sensitivity and specificity of home polygraphy for identifying the sleep-disordered breathing pattern was 100%. These data show that home cardiorespiratory polygraphy has a high sensitivity and specificity for the diagnosis of sleep-disordered breathing associated with heart failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Kaneko, Y., Floras, J. S., Usui, K., Plante, J., Tkacova, R., Kubo, T., Ando, S.-I., & Bradley, T. D. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022479 · Cited by 1,051 · cited 1×
“This association is particularly relevant due to the high prevalence of both conditions [5, 6] and the adverse prognostic implications of breathing disorders in heart failure [7, 8]. Recent studies [9, 10 ] have provided important insight into the pathophysiology of sleep apnoea syndrome in patients with congestive he…”
BackgroundChervin, R. D., Murman, D. L., Malow, B. A., & Totten, V. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00006 · Cited by 138
Home sleep studies in the assessment of sleep apnea/hypopnea syndrome
Golpe, R., Jime´nez, A., & Carpizo, R. (2002) · Chest · doi:10.1378/chest.122.4.1156 · Cited by 109
Cited by
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Sleep disordered breathing and post-discharge mortality in patients with acute heart failure
Khayat, R., Jarjoura, D., Porter, K., Sow, A., Wannemacher, J., Dohar, R., Pleister, A., & Abraham, W. T. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu522 · Cited by 278
“Cardiorespiratory polygraphy is widely used for the diagnosis of obstructive sleep apnoea (OSA) and central sleep apnoea (CSA) in patients with HF.11,15,16 We have reported on our validation of in-hospital testing in AHF patients and its high positive predictive value (.90”
MethodInfluentialEl Shayeb, M., Topfer, L.-A., Stafinski, T., Pawluk, L., & Menon, D. (2014) · Canadian Medical Association Journal · doi:10.1503/cmaj.130952 · Cited by 237
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
“The results indicate that, if moving patients can be avoided using a telematic approach to home diagnosis, initial exclusion of these patients may not be necessary. A study examining patients with chronic heart failure has shown that HRP has good diagnostic accuracy for SAHS,”
Background
Metadata
- Authors
- Quintana-Gallego, E., Villa-Gil, M., Carmona-Bernal, C., Botebol-Benhamou, G., Martínez-Martínez, Á., Sánchez-Armengol, Á., Polo-Padillo, J., & Capote, F.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2004-09
- Volume
- 24
- Issue
- 3
- Pages
- 443-448
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2164837595
- Cited by
- 90
- References
- 6
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Home respiratory polygraphy for diagnosis of sleep-disordered breathing in heart failure. https://app.cochat.ai/papers/10.1183/09031936.04.00140603
- The paper
- Quintana-Gallego, E., Villa-Gil, M., Carmona-Bernal, C., Botebol-Benhamou, G., Martínez-Martínez, Á., Sánchez-Armengol, Á., Polo-Padillo, J., & Capote, F. (2004). Home respiratory polygraphy for diagnosis of sleep-disordered breathing in heart failure. European Respiratory Journal. https://doi.org/10.1183/09031936.04.00140603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.