The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Standardisation of spirometry
Open accessAbstract
This is a document produced by a joint ATS-ERS Task Force on lung function testing to provide new combined standards for Spirometry. It walks the reader through all the important elements of the test, from instrument to procedure quality control. One of the major steps forward is the recommendation that a standardised computer output format should be available on all instruments. This does not require equipment manufacturers to store their data in a specific format, but it does require them to provide a means of delivering the data in a standard way. This means that users won't be tied to a specific manufacturer in order to maintain their database structure. It also means that it will be relatively easy to write software to move spirometric data into healthcare databases where they can be used to monitor and guide therapy for patients with lung diseases. Such data can also be used for clinical research, including research into the efficacy of using pulmonary function tests in managing patients. Furthermore, International Organization for Standardization metrology terminology (www.iso.org) has been adopted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Centrally reviewed spirometry evaluations were required to meet acceptability and repeatability criteria (19).”
From Efficacy and Safety of Admilparant, an LPA1 Antagonist, in Pulmonary Fibrosis: A Phase 2 Randomized Clinical Trial. (2025) · cites this paper as [19]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“THM samples were analyzed in an accredited laboratory, and spirometry and FENO examinations were performed in accordance with ATS guidelines. [30,34]”
From Occupational exposure to trichloramine and trihalomethanes: adverse health effects among personnel in habilitation and rehabilitation swimming pools (2019) · cites this paper as [30]
In the citing paper
“Forced expiratory volume in 1 sec (FEV1) and forced vital capacity (FVC) were measured 30 min before and 60 min after participants swam, with an EasyOne portable spirometer (ndd Medical Technologies, Zürich, Switzerland) following standard recommendations (Miller et al. 2005).”
From Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool (2010) · cites this paper as Miller et al. 2005
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standardization of Spirometry, 1994 Update. American Thoracic Society.
(1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.3.7663792 · Cited by 6,594
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Self-citationLung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Self-citationStandardisation of the measurement of lung volumes
Wanger, J., Clausen, J. L., Coates, A., Pedersen, O. F., Brusasco, V., Burgos, F., Casaburi, R., Crapo, R., Enright, P., van der Grinten, C. P. M., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035005 · Cited by 2,768
Self-citationStandardization of Spirometry—1987 Update
(1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.5.1285 · Cited by 2,315
Standardized lung function testing.
Thornton, J. C., & Miller, A. (1984) · PubMed · Cited by 1,310
O'DONNELL, D. E., LAM, M., & WEBB, K. A. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.2.9901038 · Cited by 485
Guidelines for the measurement of respiratory function
British Thoracic Society (1994) · Respiratory Medicine · doi:10.1016/s0954-6111(05)80346-4 · Cited by 282
Spirometric Pulmonary Function in Healthy Preschool Children
EIGEN, H., BIELER, H., GRANT, D., CHRISTOPH, K., TERRILL, D., HEILMAN, D. K., AMBROSIUS, W. T., & TEPPER, R. S. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2002054 · Cited by 275
Quality Control for Spirometry in Preschool Children with and without Lung Disease
Aurora, P., Stocks, J., Oliver, C., Saunders, C., Castle, R., Chaziparasidis, G., & Bush, A. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200310-1453oc · Cited by 237
Research works printed but not linked: 17
- 1979, Am Rev Respir Dis, 119, 831
- 1983, Bull Eur Physiopathol Respir, 19, 1
- 1986, Am Rev Respir Dis, 134, 626
- 1975, Am Rev Respir Dis, 112, 882
- 1982, Am Rev Respir Dis, 126, 362
- 1978, Bull Eur Physiopathol Respir, 14, 146
- 1983, Am Rev Respir Dis, 127, 720
- 1986, Bull Eur Physiopathol Respir, 22, 451
- 1983, Ugerkr Laeger, 145, 2752
- 1978, Bull Eur Physiopathol Respir, 14, 145
- 1983, J Appl Physiol, 44, 1354
- 1986, J Occup Med, 28, 1222
- 1983, Am Rev Respir Dis, 128, 894
- 1982, Am Rev Respir Dis, 126, 362
- 1986, Am Rev Respir Dis, 134, 626
- 2000, Am J Respir Crit Care Med, 162, 1887
- 1982, Bull Eur Physiopath Respir, 18, 491
Cited by
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Raghu, G., Collard, H. R., Egan, J. J., Martinez, F. J., Behr, J., Brown, K. K., Colby, T. V., Cordier, J.-F., Flaherty, K. R., Lasky, J. A., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2009-040gl · Cited by 7,186
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Self-citationEfficacy and Safety of Nintedanib in Idiopathic Pulmonary Fibrosis
Richeldi, L., du Bois, R. M., Raghu, G., Azuma, A., Brown, K. K., Costabel, U., Cottin, V., Flaherty, K. R., Hansell, D. M., Inoue, Y., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1402584 · Cited by 4,654
Graham, B. L., Steenbruggen, I., Miller, M. R., Barjaktarevic, I. Z., Cooper, B. G., Hall, G. L., Hallstrand, T. S., Kaminsky, D. A., McCarthy, K., McCormack, M. C., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1590st · Cited by 4,305
Self-citation
Metadata
- Authors
- Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., Jensen, R., Johnson, D. C., MacIntyre, N., McKay, R., Navajas, D., Pedersen, O. F., Pellegrino, R., Viegi, G., & Wanger, J.
- Affiliations
- University Hospitals Birmingham NHS Foundation Trust (GB)
- University of Genoa (IT)
- Corresponding author
- Brusasco, V.
- ORCID
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-08
- Volume
- 26
- Issue
- 2
- Pages
- 319-338
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2125078269
- Cited by
- 15,627
- References
- 63
- Citations by year
- 2026: 452 · 2025: 640 · 2024: 746 · 2023: 849 · 2022: 1062 · 2021: 1204 · 2020: 1252 · 2019: 1124 · 2018: 1088 · 2017: 1002 · 2016: 904 · 2015: 932 · 2014: 885 · 2013: 829 · 2012: 660
- FWCI
- 131.54
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- European Respiratory Journal (publishedVersion)
- PubMed (publishedVersion)
- CINECA IRIS Institutial Research Information System (University of Genoa) (submittedVersion)
- Funders
- Massachusetts General Hospital
- University Hospitals Birmingham NHS Foundation Trust
- Universitat de Barcelona
- Hospital for Sick Children
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- pulmonary function tests, spirometry quality control, health databases, lung disease monitoring, clinical research data
- MeSH terms
- Humans, Maximal Voluntary Ventilation, Peak Expiratory Flow Rate, Spirometry, Vital Capacity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardisation of spirometry. https://app.cochat.ai/papers/10.1183/09031936.05.00034805
- The paper
- Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., Jensen, R., Johnson, D. C., MacIntyre, N., McKay, R., Navajas, D., Pedersen, O. F., Pellegrino, R., Viegi, G., & Wanger, J. (2005). Standardisation of spirometry. European Respiratory Journal. https://doi.org/10.1183/09031936.05.00034805
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.