The DOI matches its Crossref record.
Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging
Open accessAbstract
Accurate staging of the mediastinum in lung cancer is essential for optimising treatment strategies. Conventional transbronchial needle aspiration (TBNA) is a blind procedure, reliant upon prior computed tomography (CT) or ultrasound imaging, but has low sensitivity. The current study reports the initial experience of using a prototype endobronchial ultrasound (EBUS) probe that allows TBNA under real-time imaging. In 20 patients selected by CT scanning, a linear-array ultrasound bronchoscope was used to visualise paratracheal and hilar lymph nodes, and TBNA was performed under direct ultrasonic control. In seven cases, sequential endoscopic ultrasound (EUS) was used to assess postero-inferior mediastinal lymph nodes. All procedures were performed under conscious sedation. EBUS-TBNA was undertaken in 18 out of 20 cases and EUS-guided fine-needle aspiration in six out of seven cases. Cytology showed node (N)2/N3 disease in 11 out of 18 EBUS-TBNA cases and provided a primary diagnosis for eight patients. EBUS-TBNA cytology was negative in six cases, which was confirmed by mediastinoscopy or clinical follow-up in four. EUS provided additional information in all cases. There were no procedural complications. Sensitivity, specificity and accuracy for EBUS-TBNA were 85%, 100% and 89%, respectively. In conclusion, endobronchial ultrasound with real-time transbronchial needle aspiration offers improved sensitivity and accuracy for staging of the middle mediastinum, and, combined with endoscopic ultrasound, should allow investigation of the majority of the mediastinum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Invasive Mediastinal Staging of Lung Cancer
Detterbeck, F. C., Jantz, M. A., Wallace, M., Vansteenkiste, J., & Silvestri, G. A. (2007) · Chest · doi:10.1378/chest.07-1362 · Cited by 685
Gu, P., Zhao, Y.-Z., Jiang, L.-Y., Zhang, W., Xin, Y., & Han, B.-H. (2009) · European Journal of Cancer · doi:10.1016/j.ejca.2008.11.043 · Cited by 620
Adams, K., Shah, P. L., Edmonds, L., & Lim, E. (2009) · Thorax · doi:10.1136/thx.2008.109868 · Cited by 370
Ernst, A., Anantham, D., Eberhardt, R., Krasnik, M., & Herth, F. J. F. (2008) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e3181753b5e · Cited by 322
Vilmann, P., Frost Clementsen, P., Colella, S., Siemsen, M., De Leyn, P., Dumonceau, J.-M., Herth, F. J., Larghi, A., Vazquez-Sequeiros, E., Hassan, C., et al. (2015) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezv194 · Cited by 293
Metadata
- Authors
- Rintoul, R. C., Skwarski, K. M., Murchison, J. T., Wallace, W. A., Walker, W. S., & Penman, I. D.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2005-03
- Volume
- 25
- Issue
- 3
- Pages
- 416-421
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2001588145
- Cited by
- 309
- References
- 0
- FWCI
- 19.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging. https://app.cochat.ai/papers/10.1183/09031936.05.00095404
- The paper
- Rintoul, R. C., Skwarski, K. M., Murchison, J. T., Wallace, W. A., Walker, W. S., & Penman, I. D. (2005). Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging. European Respiratory Journal. https://doi.org/10.1183/09031936.05.00095404
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.