Mandibular advancement and obstructive sleep apnoea: a method for determining effective mandibular protrusion
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The objectives of the study were to test the hypotheses that it is possible, during routine polysomnography (PSG), to prospectively identify favourable candidates for mandibular repositioning appliance (MRA) therapy in the treatment of obstructive sleep apnoea (OSA) and to accurately estimate an optimal protrusive distance at which to fabricate the MRA. A series of subjects underwent a remotely controlled mandibular positioner (RCMP) test during PSG monitoring. The ability of the RCMP test to eliminate OSA and the target protrusion at which that occurred was compared with the success of a custom oral MRA in the 33 subjects who completed the protocol. The RCMP test was a success in 15 subjects and a failure in 18 subjects. Appliance therapy was initiated in 38 subjects and completed in 33. MRA therapy was successful at target protrusion in 80% of subjects who had a successful RCMP test and failed in 78% of those who failed the RCMP test. In conclusion the remotely controlled mandibular positioner test outcome demonstrated a statistically significant association with mandibular repositioning appliance outcome. The target protrusion determined during the remotely controlled mandibular positioner test was the effective therapeutic protrusion in subjects with a successful remotely controlled mandibular positioner test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prospective Study of the Association between Sleep-Disordered Breathing and Hypertension
Peppard, P. E., Young, T., Palta, M., & Skatrud, J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200005113421901 · Cited by 4,973 · cited 1×
“OSA is a risk factor for hypertension and consequent cardiovascular morbidity, as well as excessive daytime sleepiness, and it’s associated impairment in function and quality of life [ 5 ].”
BackgroundA Randomized, Controlled Study of a Mandibular Advancement Splint for Obstructive Sleep Apnea
MEHTA, A., QIAN, J., PETOCZ, P., DARENDELILER, M. A., & CISTULLI, P. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2004213 · Cited by 514
Ferguson, K. A., Ono, T., Lowe, A. A., Keenan, S. P., & Fleetham, J. A. (1996) · Chest · doi:10.1378/chest.109.5.1269 · Cited by 495
Ferguson, K. A., Ono, T., Lowe, A. A., al-Majed, S., Love, L. L., & Fleetham, J. A. (1997) · Thorax · doi:10.1136/thx.52.4.362 · Cited by 391
Development of a Disease-specific Health-related Quality of Life Questionnaire for Sleep Apnea
WARD FLEMONS, W., & REIMER, M. A. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.2.9712036 · Cited by 333
Randerath, W. J., Heise, M., Hinz, R., & Ruehle, K.-H. (2002) · Chest · doi:10.1378/chest.122.2.569 · Cited by 257
Compliance With Nasal CPAP Can Be Improved by Simple Interventions
Chervin, R. D., Theut, S., Bassetti, C., & Aldrich, M. S. (1997) · Sleep · doi:10.1093/sleep/20.4.284 · Cited by 242
Tan, Y. K. (2002) · The European Journal of Orthodontics · doi:10.1093/ejo/24.3.239 · Cited by 206
Cited by
Oral Appliance Treatment for Obstructive Sleep Apnea: An Update
Sutherland, K., Vanderveken, O. M., Tsuda, H., Marklund, M., Gagnadoux, F., Kushida, C. A., Cistulli, P. A., & on behalf of the ORANGE-Registry (Oral Appliance Network on Global Effectiveness) (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3460 · Cited by 515
“98,99 This method involves use of a remotely controlled intraoral device during an attended sleep study to incrementally advance the mandible until sleep disordered breathing events are eliminated, analogous to a CPAP pressure titration study.”
Non-CPAP therapies in obstructive sleep apnoea
Randerath, W. J., Verbraecken, J., Andreas, S., Bettega, G., Boudewyns, A., Hamans, E., Jalbert, F., Paoli, J. R., Sanner, B., Smith, I., et al. (2011) · European Respiratory Journal · doi:10.1183/09031936.00099710 · Cited by 388
Titrated mandibular advancement versus positive airway pressure for sleep apnoea
Gagnadoux, F., Fleury, B., Vielle, B., Pételle, B., Meslier, N., N’Guyen, X. L., Trzepizur, W., & Racineux, J. L. (2009) · European Respiratory Journal · doi:10.1183/09031936.00148208 · Cited by 275
Remmers, J., Charkhandeh, S., Grosse, J., Topor, Z., Brant, R., Santosham, P., & Bruehlmann, S. (2013) · Sleep · doi:10.5665/sleep.3048 · Cited by 172
Self-citationOral appliance treatment of obstructive sleep apnea: an update
Chan, A. S., & Cistulli, P. A. (2009) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0b013e3283319b12 · Cited by 103
Metadata
- Authors
- Dort, L. C., Hadjuk, E., & Remmers, J. E.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2006-05
- Volume
- 27
- Issue
- 5
- Pages
- 1003-1009
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2097336809
- Cited by
- 104
- References
- 8
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.