The DOI matches its Crossref record.
Lung CT density correlates with measurements of airflow limitation and the diffusing capacity
Open accessAbstract
We studied 80 subjects (63 M, 17 F; 23-82 yrs) and related lung computerized tomography (CT) density with age, height, spirometry, lung volumes, diffusing capacity and arterial blood gas tensions. These subjects demonstrated a wide range of physiological impairment (forced expiratory volume in one second (FEV1) 8-116% predicted; diffusing capacity (Kco) 15-139% predicted; arterial oxygen tension (Pao2) 38-91 mmHg). They ranged from normal subjects to patients with chronic respiratory failure. Lung density was derived from CT density histograms measured as both mean Emergency Medical Information (EMI) number (EMI scale: 0 = water, -500 = air, EMI number of normal lung tissue range approximately -200 to -450) and the lowest 5th percentile EMI number, the latter value being more likely to represent the density of lung parenchyma. Lung CT density correlated most strongly with airflow obstruction (EMI 5th percentile versus FEV1/forced vital capacity (FVC) % predicted, r = 0.73, p less than 0.001) and diffusing capacity (EMI 5th percentile versus Kco, r = 0.77, p less than 0.001). This suggests that reduction in lung density, which reflects loss of the surface area of the distal airspaces, is a major index of respiratory function in patients with smoking related chronic obstructive pulmonary disease (COPD). These data provide no indication of other factors such as small and large airways disease, and loss of elastic recoil, which may contribute to airflow limitation, or disruption of the pulmonary vascular bed which may also affect CT lung density.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Standardisation of the single-breath determination of carbon monoxide uptake in the lung
MacIntyre, N., Crapo, R. O., Viegi, G., Johnson, D. C., van der Grinten, C. P. M., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034905 · Cited by 2,255
2017 ERS/ATS standards for single-breath carbon monoxide uptake in the lung
Graham, B. L., Brusasco, V., Burgos, F., Cooper, B. G., Jensen, R., Kendrick, A., MacIntyre, N. R., Thompson, B. R., & Wanger, J. (2017) · European Respiratory Journal · doi:10.1183/13993003.00016-2016 · Cited by 972
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.168.7.818 · Cited by 911
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Self-citationStandardization of the measurement of transfer factor (diffusing capacity)
Cotes, J. E., Chinn, D. J., Quanjer, P. H., Roca, J., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.041s1693 · Cited by 680
Metadata
- Authors
- Gould, G., Redpath, A., Ryan, M., Warren, P., Best, J., Flenley, D., & MacNee, W.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1991-02-01
- Volume
- 4
- Issue
- 2
- Pages
- 141-146
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1824111720
- Cited by
- 206
- References
- 0
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lung CT density correlates with measurements of airflow limitation and the diffusing capacity. https://app.cochat.ai/papers/10.1183/09031936.93.04020141
- The paper
- Gould, G., Redpath, A., Ryan, M., Warren, P., Best, J., Flenley, D., & MacNee, W. (1991). Lung CT density correlates with measurements of airflow limitation and the diffusing capacity. European Respiratory Journal. https://doi.org/10.1183/09031936.93.04020141
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.