The DOI matches its Crossref record.
Evaluation of the solitary pulmonary nodule by positron emission tomography imaging
Abstract
Current noninvasive imaging methods are not sufficiently reliable for accurate detection of malignancy in most solitary pulmonary nodules (SPNs). Positron emission tomography (PET) using 18-fluorodeoxyglucose (FDG), showing increased FDG uptake and retention in malignant cells, has proved useful to differentiate malignant from benign tissue and could, therefore, contribute to the evaluation of the SPN. We performed a prospective study of 50 patients referred to the Pneumology Department with unclear diagnoses of SPN after conventional radiological screening. PET study was performed on each subject before an invasive procedure was proposed. Thirty three patients had a malignant nodule and 17 had a benign nodule. The mean size of malignant nodule was 3 cm (range 1.5-4.5 cm). All showed a marked increase in 18-FDG uptake. The mean size of benign nodule was 1.8 cm (range 0.5-3.5 cm). PET imaging showed the absence of 18-FDG uptake and correctly identified 15 of 17 benign nodules. There was two false-positive cases with a moderate increase in 18-FDG uptake (1 postprimary tuberculosis; and 1 anthracosilicotic nodule with nonspecific inflammation). At present, the sensitivity and specificity of the method are 100 and 88%, respectively. The positive and negative predictive values of PET imaging for SPNs are 94 and 100%, respectively. Our preliminary results demonstrate that PET-FDG imaging is a noninvasive technique, which appears highly accurate in differentiating malignant SPN from benign SPN.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2001) · PubMed · Cited by 943
Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose
Rigo, P., Paulus, P., Kaschten, B. J., Hustinx, R., Bury, T., Jerusalem, G., Benoit, T., & Foidart-Willems, J. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01249629 · Cited by 501
Self-citationGuidelines for radiologically guided lung biopsy
Manhire, A. (2003) · Thorax · doi:10.1136/thorax.58.11.920 · Cited by 492
Vansteenkiste, J. F., Stroobants, S. G., De Leyn, P. R., Dupont, P. J., Bogaert, J., Maes, A., Deneffe, G. J., Nackaerts, K. L., Verschakelen, J. A., Lerut, T. E., et al. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.6.2142 · Cited by 410
Clinical Role of FDG PET in Evaluation of Cancer Patients
Kostakoglu, L., Agress, H., & Goldsmith, S. J. (2003) · RadioGraphics · doi:10.1148/rg.232025705 · Cited by 402
Metadata
- Authors
- Bury, T., Dowlati, A., Paulus, P., Corhay, J., Benoit, T., Kayembe, J., Limet, R., Rigo, P., & Radermecker, M.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1996-03-01
- Volume
- 9
- Issue
- 3
- Pages
- 410-414
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2107376332
- Cited by
- 179
- References
- 0
- FWCI
- 11.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the solitary pulmonary nodule by positron emission tomography imaging. https://app.cochat.ai/papers/10.1183/09031936.96.09030410
- The paper
- Bury, T., Dowlati, A., Paulus, P., Corhay, J., Benoit, T., Kayembe, J., Limet, R., Rigo, P., & Radermecker, M. (1996). Evaluation of the solitary pulmonary nodule by positron emission tomography imaging. European Respiratory Journal. https://doi.org/10.1183/09031936.96.09030410
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.