Objective patient compliance in long-term use of nCPAP
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Concerns remain regarding patient compliance with nasal continuous positive airway pressure (nCPAP). Poor objective compliance during the first months of treatment has been reported, but no data are available among chronically treated patients. Use of nCPAP, in 17 chronically treated obstructive sleep apnoea patients (820+/-262 days) was evaluated objectively using a pressure monitor (MC+; Sefam, France). Two consecutive recording periods of 30 sessions of treatment were scheduled at the patient's home. To minimize the potential bias caused by the introduction of the monitor, only the pressure data obtained at the end of the second period of recording (T2) were analysed. During the 28.1+/-2.6 monitored days, the mean effective daily rate of use was 7.1+/-1.1 h, 97% of the rate indicated by the standard in-built time counter. The prescribed pressure was observed during 95% of the machine run time. The nCPAP system was used for 94% of the monitored days. Sixty percent of the patients used their device every day. These preliminary results suggest that, contrary to reported compliance during the early period of the treatment, objective use of nasal continuous positive airway pressure therapy in chronically treated patients is satisfactory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Objective Measurement of Patterns of Nasal CPAP Use by Patients with Obstructive Sleep Apnea
Kribbs, N. B., Pack, A. I., Kline, L. R., Smith, P. L., Schwartz, A. R., Schubert, N. M., Redline, S., Henry, J. N., Getsy, J. E., & Dinges, D. F. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.4.887 · Cited by 1,339 · cited 2×
“The few studies performed to objectively assess compliance, using a pressure transducer incorporated into the pneumatic circuitry of the CPAP machine, describe poor use of the equipment [6, 7].”
BackgroundContinuous Versus Bilevel Positive Airway Pressure for Obstructive Sleep Apnea
Reeves-Hoché, M. K., Hudgel, D. W., Meck, R., Witteman, R., Ross, A., & Zwillich, C. W. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.151.2.7842204 · Cited by 192
Cited by
Obstructive sleep apnoea syndrome
Lévy, P., Kohler, M., McNicholas, W. T., Barbé, F., McEvoy, R. D., Somers, V. K., Lavie, L., & Pépin, J.-L. (2015) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2015.15 · Cited by 1,235
Jokic, R., Klimaszewski, A., Crossley, M., Sridhar, G., & Fitzpatrick, M. F. (1999) · Chest · doi:10.1378/chest.115.3.771 · Cited by 250
Early Predictors of CPAP Use for the Treatment of Obstructive Sleep Apnea
Lewis, K. E., Seale, L., Bartle, I. E., Watkins, A. J., & Ebden, P. (2004) · Sleep · doi:10.1093/sleep/27.1.134 · Cited by 242
Zozula, R., & Rosen, R. (2001) · Current Opinion in Pulmonary Medicine · doi:10.1097/00063198-200111000-00005 · Cited by 189
Pelletier-Fleury, N., Rakotonanahary, D., & Fleury, B. (2001) · Sleep Medicine · doi:10.1016/s1389-9457(00)00063-0 · Cited by 162
Self-citation
Metadata
- Authors
- Fleury, B., Rakotonanahary, D., Hausser-Hauw, C., Lebeau, B., & Guilleminault, C.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1996-11-01
- Volume
- 9
- Issue
- 11
- Pages
- 2356-2359
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2148582005
- Cited by
- 30
- References
- 3
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Objective patient compliance in long-term use of nCPAP. https://app.cochat.ai/papers/10.1183/09031936.96.09112356
- The paper
- Fleury, B., Rakotonanahary, D., Hausser-Hauw, C., Lebeau, B., & Guilleminault, C. (1996). Objective patient compliance in long-term use of nCPAP. European Respiratory Journal. https://doi.org/10.1183/09031936.96.09112356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.