Acoustic analysis of snoring sound in patients with simple snoring and obstructive sleep apnoea
Open accessThe DOI matches its Crossref record.
Abstract
Snoring, a symptom which may indicate the presence of the obstructive sleep apnoea syndrome (OSA), is also common in the general population. Recent studies have suggested that the acoustic characteristics of snoring sound may differ between simple snorers and OSA patients. We have studied a small number of patients with simple snoring and OSA, analysing the acoustic characteristics of the snoring sound. Seventeen male patients, 10 with OSA (apnoea/hypopnoea index (AHI) 26.2 events x h(-1)) and seven simple snorers (AHI 3.8 events x h(-1)), were studied. Full night polysomnography was performed and the snoring sound power spectrum was analysed. Spectral analysis of snoring sound showed the existence of two different patterns. The first pattern was characterized by the presence of a fundamental frequency and several harmonics. The second pattern was characterized by a low frequency peak with the sound energy scattered on a narrower band of frequencies, but without clearly identified harmonics. The seven simple snorers and two of the 10 patients with OSA (AIH 13 and 14 events x h(-1), respectively) showed the first pattern. The rest of the OSA patients showed the second pattern. The peak frequency of snoring was significantly lower in OSA patients, with all but one OSA patient and only one simple snorer showing a peak frequency below 150 Hz. A significant negative correlation was found between AHI and peak and mean frequencies of the snoring power spectrum (p<0.0016 and p<0.0089, respectively). In conclusion, this study demonstrates significant differences in the sound power spectrum of snoring sound between subjects with simple snoring and obstructive sleep apnoea patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sleep Apnea Monitoring using mobile phones
Alqassim, S., Ganesh, M., Khoja, S., Zaidi, M., Aloul, F., & Sagahyroon, A. (2012) · 2012 IEEE 14th International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2012.6379457 · Cited by 55
“Two other studies presented in [10] and [11] propose methodologies and tools to differentiate simple snoring from the snoring of sleep apnea patients.”
BackgroundEvaluation of the clinical efficacy of nasal surgery in the treatment of obstructive sleep apnoea
Wu, J., He, S., Li, Y., Wang, T., Zhao, G., Pan, Y., Zang, H., & Han, D. (2022) · American Journal of Otolaryngology · doi:10.1016/j.amjoto.2021.103158 · Cited by 12
Metadata
- Authors
- Fiz, J., Abad, J., Jane, R., Riera, M., Mananas, M., Caminal, P., Rodenstein, D., & Morera, J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1996-11-01
- Volume
- 9
- Issue
- 11
- Pages
- 2365-2370
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2152791479
- Cited by
- 194
- References
- 0
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acoustic analysis of snoring sound in patients with simple snoring and obstructive sleep apnoea. https://app.cochat.ai/papers/10.1183/09031936.96.09112365
- The paper
- Fiz, J., Abad, J., Jane, R., Riera, M., Mananas, M., Caminal, P., Rodenstein, D., & Morera, J. (1996). Acoustic analysis of snoring sound in patients with simple snoring and obstructive sleep apnoea. European Respiratory Journal. https://doi.org/10.1183/09031936.96.09112365
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.