Effect of short- and long-acting inhaled beta2-agonists on exhaled nitric oxide in asthmatic patients
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Increased concentrations of exhaled nitric oxide (NO) occur in patients with asthma, and exhaled NO may be useful for assessing the effect of drug therapy on airway inflammation. Beta2-agonists have been proposed to have both proinflammatory and anti-inflammatory effects. We therefore assessed exhaled NO after beta2-agonists in asthmatic patients. Two randomized, double-blind, placebo-controlled studies were conducted. Firstly, exhaled NO was measured in 18 asthmatics (9 taking inhaled glucocorticosteroids (GCS)) before and after nebulized salbutamol (5 mg), or identical placebo (0.9% saline). Exhaled NO and forced expiratory volume in one second (FEV1) were measured at 15 min intervals for 1 h (Study 1). Secondly, the effect of 1 week of treatment with the long-acting beta2-agonist, salmeterol (50 microg b.i.d.), added to either budesonide (800 microg b.i.d.) or placebo, was studied in eight mild asthmatic subjects (Study 2). Exhaled NO was measured by a chemiluminescence analyser, adapted for on-line recording. In Study 1, exhaled NO showed no significant change at any time-point in patients not taking inhaled GCS. In asthmatics on inhaled GCS, exhaled NO increased compared to placebo at 15 and 30 min, but this did not reach statistical significance. In Study 2, treatment with salmeterol increased FEV1, but exhaled NO levels were not significantly changed, either after budesonide treatment (143+/-35 to 179+/-67 ppb), or after placebo (201+/-68 to 211+/-65 ppb). Our results confirm that single high dose salbutamol does not increase exhaled nitric oxide in asthmatics not taking inhaled glucocorticosteroids. Salbutamol may increase exhaled nitric oxide in asthmatics taking inhaled glucocorticosteroids. However, regular use of salmeterol resulted in no change in exhaled nitric oxide, either used alone or in combination with inhaled glucocorticosteroids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increased amount of nitric oxide in exhaled air of asthmatics
Alving, K., Weitzberg, E., & Lundberg, J. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06091368 · Cited by 1,232 · cited 2×
“NO can be measured in the exhaled air of humans, either directly in expired air [2], or indirectly by collection in NO-impermeable bags [3, 4], but all methods show significant correlation [5].”
BackgroundMethod
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Neutrophilic Inflammation in Severe Persistent Asthma
JATAKANON, A., UASUF, C., MAZIAK, W., LIM, S., CHUNG, K. F., & BARNES, P. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.5.9806170 · Cited by 851
Self-citationExhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Self-citation(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.6.ats8-99 · Cited by 771
Jatakanon, A., Lim, S., Kharitonov, S. A., Chung, K. F., & Barnes, P. J. (1998) · Thorax · doi:10.1136/thx.53.2.91 · Cited by 688
Self-citation
Metadata
- Authors
- Yates, D., Kharitonov, S., & Barnes, P.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1997-07-01
- Volume
- 10
- Issue
- 7
- Pages
- 1483-1488
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2108452934
- Cited by
- 94
- References
- 1
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.