CoChat

Nasal prongs in the detection of sleep-related disordered breathing in the sleep apnoea/hypopnoea syndrome

Open access
Ballester, E, Badia, Hernandez, L, Farre, R, Navajas, D, Montserrat, JM · 1998 · European Respiratory Journal
Cited by 82

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Conventional systems to monitor oronasal flow in sleep studies have traditionally relied on a thermistor signal. Our study was designed to verify whether nasal prongs (NP) connected to a pressure transducer could improve respiratory events detection in patients with sleep apnoea/hypopnoea syndrome (SAHS) compared to traditional systems. Sleep episodes from a 2 h conventional polysomnographic record plus NP signal obtained at random from eight patients (age: mean(+/-SD) 53(+/-12) yrs; body mass index (BMI): 29(+/-6) kg x m(-2); apnoea/hypopnoea index (AHI): 27(+/-20) events x h(-1)) were identified and used for analysis. An abnormal change in the pattern of any of the respiratory or neurological variables occurring during the observation period was defined as an episode. Each episode was registered and scored with concomitant scoring of the remaining variables. According to the episode definition three different profiles were established: 1) periods of reduction of ventilation in either variable without an arousal or cyclical desaturation, named nonpathological episode (NPE); 2) an idiopathic or nonrespiratory arousal (IA); and 3) a true respiratory event (TRE) defined as reduction or absence of flow demonstrated by either thermistor, thoraco-abdominal bands or NP accompanied by cyclical desaturation and/or arousal. For each TRE, its detection by thermistor, thoraco-abdominal bands or NP was established. A total of 877 sleep episodes were observed (42 NPE, 30 IA and 805 TRE). When compared to single or combined thermistor and bands approach, NP had the highest respiratory events detection rate, 779 (96.8%) versus 673 events (83.6%), respectively. Detection of respiratory-related arousals was also improved by NP and only 3% could account for mouth breathing respiration. It is concluded that nasal prongs improve the detection of respiratory events in patients with sleep respiratory disorders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.98.11040880

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 82

Metadata

Authors
Ballester, E., Badia, Hernandez, L., Farre, R., Navajas, D., & Montserrat, J.
Venue
European Respiratory Journal
Published
1998-04-01
Volume
11
Issue
4
Pages
880-883
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2162922595
Cited by
82
References
1
FWCI
2.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nasal prongs in the detection of sleep-related disordered breathing in the sleep apnoea/hypopnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.98.11040880
The paper
Ballester, E., Badia, Hernandez, L., Farre, R., Navajas, D., & Montserrat, J. (1998). Nasal prongs in the detection of sleep-related disordered breathing in the sleep apnoea/hypopnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.98.11040880

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.