CoChat

Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome

Open access
Meurice, JC, Paquereau, J, Denjean, A, Patte, F, Series, F · 1998 · European Respiratory Journal
Cited by 75

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We evaluated the efficiency of two different treatment procedures with continuous positive airway pressure (CPAP) on sleep, nocturnal breathing characteristics and daytime vigilance in 18 newly diagnosed patients with untreated sleep apnoea/hypopnoea syndrome (SAHS) randomly allocated to two different groups. In group I, the positive pressure (PP) level was set to suppress flow limitation (PFL), while in group II the PP was set at a level that eliminated only apnoea/hypopnoea and snoring (PAHS). At the end of a 3 week period of home CPAP therapy, a follow-up sleep study, vigilance and cognitive tests were made. Overall, PFL was significantly higher than PAHS values (PFL: 10.42.6 cmH2O; PAHS: 8.9+/-2.6 cmH2O; p<0.01, mean+/-SD). We found no difference in sleep quality, nocturnal saturation and apnoea/hypopnoea index, or in daytime vigilance tests between the two groups at the end of the treatment period. However, there was a significantly greater scattering in the changes of sleep latency in group II than in group I. This was associated with a significant difference in the daily duration of nasal CPAP use between the two groups (group I: 7.29+/-0.95 h x day(-1); group II: 6.01+/-0.94 h x day(-1); p=0.01) and with a positive correlation between final maintenance of wakefulness test values and the duration of CPAP use (p<0.05; r=0.55). These results tend to show that correcting flow limitation is associated with a higher observance and a more important efficiency in normalizing daytime vigilance than with conventional nasal continuous positive airway pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.98.11051121

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 75

Metadata

Authors
Meurice, J., Paquereau, J., Denjean, A., Patte, F., & Series, F.
Venue
European Respiratory Journal
Published
1998-05-01
Volume
11
Issue
5
Pages
1121-1127
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W1984573910
Cited by
75
References
1
FWCI
2.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.98.11051121
The paper
Meurice, J., Paquereau, J., Denjean, A., Patte, F., & Series, F. (1998). Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.98.11051121

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.