The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
References values for forced spirometry. Group of the European Community Respiratory Health Survey
Open accessAbstract
The European Coal and Steel Community (ECSC) prediction equations exemplify a significant effort carried out approximately 15 yrs ago to provide uniform standards for lung function testing, but this set of equations has not been properly validated as yet. The present study evaluates the ECSC reference values and four other sets of prediction equations, using spirometric data collected in 12,900 nonasthmatic subjects (43% lifetime nonsmokers and 36% active smokers) aged 20-44 yrs from the European Community Respiratory Health Survey (ECRHS). Standardized spirometric measurements were obtained using a common protocol in 34 centres in 14 countries. For each prediction equation, the prediction deviations (i.e. observed minus predicted value) for forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) were examined for the whole study population and for each centre. For the age range included, the errors about the ECSC equations showed the most prominent underestimation of both predicted FVC (+355 and +360 mL on average in males and females, respectively) and predicted FEV1 (+211 and +200 mL, respectively) among the five studies examined. As expected, FVC and FEV1 in active smokers from the ECRHS were significantly lower than in lifetime nonsmokers (each p<0.01). We conclude that the present European recommendations on lung function reference values should be reconsidered, but further data for nonsymptomatic subjects above the age of 44 yrs are needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standardization of Spirometry, 1994 Update. American Thoracic Society.
(1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.3.7663792 · Cited by 6,594
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Self-citation(1993) · PubMed · Cited by 3,827
Standardization of Spirometry — 1987 Update
Buist, A. S. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.5.1073 · Cited by 3,266
Lung Function Testing: Selection of Reference Values and Interpretative Strategies
(1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.5.1202 · Cited by 2,510
The European Community Respiratory Health Survey
Burney, P., Luczynska, C., Chinn, S., & Jarvis, D. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07050954 · Cited by 1,996
Self-citationChanges in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,907
Reference spirometric values using techniques and equipment that meet ATS recommendations.
Terrin, M. (1981) · PubMed · doi:10.1164/arrd.1981.124.6.763c · Cited by 1,374
Standardized lung function testing.
Thornton, J. C., & Miller, A. (1984) · PubMed · Cited by 1,310
Reference spirometric values using techniques and equipment that meet ATS recommendations.
Crapo, R. O., Morris, A. H., & Gardner, R. M. (1981) · PubMed · doi:10.1164/arrd.1981.123.6.659 · Cited by 614
Spirometric reference values from a Mediterranean population.
Roca, J., Sanchis, J., Agustí-Vidal, A., Segarra, F., Navajas, D., Rodríguez-Roisin, R., Casán, P., & Sans, S. (1986) · PubMed · Cited by 499
Self-citationMiller, A., Thornton, J. C., Warshaw, R. H., et al. (1987) · PubMed · Cited by 109
Reference values for vital capacity and flow-volume curves from a general population study.
Paoletti, P., Pistelli, G., Fazzi, P., Viegi, G., Di Pede, F., Giuliano, G., Prediletto, R., Carrozzi, L., Polato, R., & Saetta, M. P. (1986) · PubMed · Cited by 107
Overview of Issues in the Longitudinal Analysis of Respiratory Data
Weiss, S. T., & Ware, J. H. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm/154.6_pt_2.s208 · Cited by 88
Prediction equations for forced spirometry from European origin populations
Castellsagué, J., Burgos, F., Sunyer, J., Barberà, J. A., & Roca, J. (1998) · Respiratory Medicine · doi:10.1016/s0954-6111(98)90282-7 · Cited by 34
Self-citationSpirometric Standards for Healthy Nonsmoking Adults
Morris, J. F., Koski, A., & Johnson, L. C. (1971) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-197107000-00021 · Cited by 8
Cited by
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Self-citationNovos valores de referência para espirometria forçada em brasileiros adultos de raça branca
Pereira, C. A. D. C., Sato, T., & Rodrigues, S. C. (2007) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132007000400008 · Cited by 866
Low Dose Inhaled Budesonide and Formoterol in Mild Persistent Asthma: The OPTIMA Randomized Trial
O'BYRNE, P. M., BARNES, P. J., RODRIGUEZ-ROISIN, R., RUNNERSTROM, E., SANDSTROM, T., SVENSSON, K., & TATTERSFIELD, A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.8.2104102 · Cited by 680
Self-citationZureik, M., Neukirch, C., Leynaert, B., Liard, R., Bousquet, J., & Neukirch, F. (2002) · BMJ · doi:10.1136/bmj.325.7361.411 · Cited by 488
de Torres, J. P., Bastarrika, G., Wisnivesky, J. P., Alcaide, A. B., Campo, A., Seijo, L. M., Pueyo, J. C., Villanueva, A., Lozano, M. D., Montes, U., et al. (2007) · Chest · doi:10.1378/chest.07-1490 · Cited by 453
Metadata
- Authors
- Roca, J., Burgos, F., Sunyer, J., Saez, M., Chinn, S., Anto, J., Rodriguez-Roisin, R., Quanjer, P., Nowak, D., & Burney, P.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1998-06-01
- Volume
- 11
- Issue
- 6
- Pages
- 1354-1362
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1891804292
- Cited by
- 291
- References
- 16
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.