Detection of apnoeas, hypopnoeas and arousals by the AutoSet in the sleep apnoea/hypopnoea syndrome
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Limited sleep study systems are increasingly being used to diagnose the sleep apnoea/hypopnoea syndrome, but validation is essential and detection of arousal's desirable. One such system (AutoSet) was validated on an event-by-event basis, and the hypothesis that sudden large breaths detected by this system mark arousal from sleep was also examined. Twenty consecutive patients (apnoea/hypopnoea index (AHI) 39+/-6 (SEM)) underwent polysomnography (PSG), which included real-time signals of AutoSet (Version 3.03) scored events. PSG respiratory events were defined using airflow and thoracoabdominal movement and AutoSet events using nasal pressure. All apnoeas were scored by both systems, but 41% more hypopnoeas were scored on PSG and these were clinically significant, with 78% ending in cortical arousal. Twenty per cent of apnoeas and hypopnoeas scored by the AutoSet occurred during wakefulness. Large breaths, defined as a two-thirds increase in ventilation, marked 77% of respiratory-associated but only 9% of spontaneous arousals. Large breaths also marked 48% of "autonomic" arousals following respiratory events without visible electroencephalographic changes. Twenty-seven per cent of large breaths occurred during wakefulness. This study shows that the AutoSet and the standard polysomnographic approach differ in their detection of hypopnoeas. The AutoSet underdetected hypopnoeas during sleep, but also included some hypopnoeas occurring during wakefulness. Detection of large breaths may potentially be useful for identifying respiratory arousals. Detection of periods of wakefulness may improve the accuracy of the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Engleman, H. M., Martin, S. E., Douglas, N. J., & Deary, I. J. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91522-9 · Cited by 592
Self-citation
Cited by
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Patel, M. R., Alexander, T. H., & Davidson, T. M. (2007) · Operative Techniques in Otolaryngology-Head and Neck Surgery · doi:10.1016/j.otot.2007.01.005 · Cited by 8
Metadata
- Authors
- Rees, K., Wraith, P., Berthon-Jones, M., & Douglas, N.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1998-10-01
- Volume
- 12
- Issue
- 4
- Pages
- 764-769
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2159975529
- Cited by
- 42
- References
- 3
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.