Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Cephalometric abnormalities in non-obese and obese patients with obstructive sleep apnoea

Sakakibara, H, Tong, M, Matsushita, K, Hirata, M, Konishi, Y, Suetsugu, S·1999·European Respiratory Journal

Abstract

The aim of this work was to comprehensively evaluate the cephalometric features in Japanese patients with obstructive sleep apnoea (OSA) and to elucidate the relationship between cephalometric variables and severity of apnoea. Forty-eight cephalometric variables were measured in 37 healthy males and 114 male OSA patients, who were classed into 54 non-obese (body mass index (BMI) <27 kg x m(-2), apnoea-hypopnoea index (AHI)=25.3+/-16.1 events x h(-1)) and 60 obese (BMI > or = 27 kg x m(-2), AHI=45.6+/-28.0 events h(-1)) groups. Diagnostic polysomnography was carried out in all of the OSA patients and in 19 of the normal controls. The non-obese OSA patients showed several cephalometric defects compared with their BMI-matched normal controls: 1) decreased facial A-P distance at cranial base, maxilla and mandible levels and decreased bony pharynx width; 2) enlarged tongue and inferior shift of the tongue volume; 3) enlarged soft palate; 4) inferiorly positioned hyoid bone; and 5) decreased upper airway width at four different levels. More extensive and severe soft tissue abnormalities with a few defects in craniofacial bony structures were found in the obese OSA group. For the non-obese OSA group, the stepwise regression model on AHI was significant with two bony structure variables as determinants: anterior cranial base length (S-N) and mandibular length (Me-Go). Although the regression model retained only linear distance between anterior vertebra and hyoid bone (H-VL) as an explainable determinant for AHI in the obese OSA group, H-VL was significantly correlated with soft tissue measurements such as overall tongue area (Ton), inferior tongue area (Ton2) and pharyngeal airway length (PNS-V). In conclusion, Japanese obstructive sleep apnoea patients have a series of cephalometric abnormalities similar to those described in Caucasian patients, and that the aetiology of obstructive sleep apnoea in obese patients may be different from that in non-obese patients. In obese patients, upper airway soft tissue enlargement may play a more important role in the development of obstructive sleep apnoea, whereas in non-obese patients, bony structure discrepancies may be the dominant contributing factors for obstructive sleep apnoea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.99.13240399

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Sakakibara, H., Tong, M., Matsushita, K., Hirata, M., Konishi, Y., & Suetsugu, S.
Venue
European Respiratory Journal
Published
1999-02-01
Volume
13
Issue
2
Pages
403-410
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2102403914
Cited by
233
References
2
FWCI
3.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cephalometric abnormalities in non-obese and obese patients with obstructive sleep apnoea. https://app.cochat.ai/papers/10.1183/09031936.99.13240399
The paper
Sakakibara, H., Tong, M., Matsushita, K., Hirata, M., Konishi, Y., & Suetsugu, S. (1999). Cephalometric abnormalities in non-obese and obese patients with obstructive sleep apnoea. European Respiratory Journal. https://doi.org/10.1183/09031936.99.13240399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.