The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Official ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians
Open accessAbstract
There are numerous reference equations available for the single-breath transfer factor of the lung for carbon monoxide (T LCO); however, it is not always clear which reference set should be used in clinical practice. The aim of the study was to develop the Global Lung Function Initiative (GLI) all-age reference values for T LCO. Data from 19 centres in 14 countries were collected to define T LCO reference values. Similar to the GLI spirometry project, reference values were derived using the LMS (lambda, mu, sigma) method and the GAMLSS (generalised additive models for location, scale and shape) programme in R. 12 660 T LCO measurements from asymptomatic, lifetime nonsmokers were submitted; 85% of the submitted data were from Caucasians. All data were uncorrected for haemoglobin concentration. Following adjustments for elevation above sea level, gas concentration and assumptions used for calculating the anatomic dead space volume, there was a high degree of overlap between the datasets. Reference values for Caucasians aged 5–85 years were derived for T LCO, transfer coefficient of the lung for carbon monoxide and alveolar volume. This is the largest collection of normative T LCO data, and the first global reference values available for T LCO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Quanjer, P. H., Stanojevic, S., Cole, T. J., Baur, X., Hall, G. L., Culver, B. H., Enright, P. L., Hankinson, J. L., Ip, M. S. M., Zheng, J., et al. (2012) · European Respiratory Journal · doi:10.1183/09031936.00080312 · Cited by 5,919
Self-citationA formula to estimate the approximate surface area if height and weight be known. 1916.
Bois, D. D., & Bois, E. F. D. (1989) · PubMed · Cited by 5,314
Du BOIS, D. (1916) · Archives of Internal Medicine · doi:10.1001/archinte.1916.00080130010002 · Cited by 4,342
Smoothing reference centile curves: The lms method and penalized likelihood
Cole, T. J., & Green, P. J. (1992) · Statistics in Medicine · doi:10.1002/sim.4780111005 · Cited by 2,781
Standardisation of the single-breath determination of carbon monoxide uptake in the lung
MacIntyre, N., Crapo, R. O., Viegi, G., Johnson, D. C., van der Grinten, C. P. M., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Enright, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034905 · Cited by 2,255
The definition of anemia: what is the lower limit of normal of the blood hemoglobin concentration?
Beutler, E., & Waalen, J. (2006) · Blood · doi:10.1182/blood-2005-07-3046 · Cited by 970
Reference Ranges for Spirometry Across All Ages: A New Approach
Stanojevic, S., Wade, A., Stocks, J., Hankinson, J., Coates, A. L., Pan, H., Rosenthal, M., Corey, M., Lebecque, P., & Cole, T. J. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200708-1248oc · Cited by 699
Self-citationStandardization of the measurement of transfer factor (diffusing capacity)
Cotes, J. E., Chinn, D. J., Quanjer, P. H., Roca, J., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.041s1693 · Cited by 680
Thurlbeck, W. M. (1982) · Thorax · doi:10.1136/thx.37.8.564 · Cited by 604
Cited by
Culver, B. H., Graham, B. L., Coates, A. L., Wanger, J., Berry, C. E., Clarke, P. K., Hallstrand, T. S., Hankinson, J. L., Kaminsky, D. A., MacIntyre, N. R., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201710-1981st · Cited by 649
Self-citationDyspnoea, lung function and CT findings 3 months after hospital admission for COVID-19
Lerum, T. V., Aaløkken, T. M., Brønstad, E., Aarli, B., Ikdahl, E., Lund, K. M. A., Durheim, M. T., Rodriguez, J. R., Meltzer, C., Tonby, K., et al. (2021) · European Respiratory Journal · doi:10.1183/13993003.03448-2020 · Cited by 339
Artificial intelligence outperforms pulmonologists in the interpretation of pulmonary function tests
Topalovic, M., Das, N., Burgel, P.-R., Daenen, M., Derom, E., Haenebalcke, C., Janssen, R., Kerstjens, H. A. M., Liistro, G., Louis, R., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01660-2018 · Cited by 238
Frésard, I., Genecand, L., Altarelli, M., Gex, G., Vremaroiu, P., Vremaroiu-Coman, A., Lawi, D., & Bridevaux, P.-O. (2022) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2021-001126 · Cited by 113
Diffusing Capacity of Carbon Monoxide in Assessment of COPD
Balasubramanian, A., MacIntyre, N. R., Henderson, R. J., Jensen, R. L., Kinney, G., Stringer, W. W., Hersh, C. P., Bowler, R. P., Casaburi, R., Han, M. K., et al. (2019) · Chest · doi:10.1016/j.chest.2019.06.035 · Cited by 100
Metadata
- Authors
- Stanojevic, S., Graham, B. L., Cooper, B. G., Thompson, B. R., Carter, K. W., Francis, R. W., & Hall, G. L.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2017-09
- Volume
- 50
- Issue
- 3
- Pages
- 1700010
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2755145368
- Cited by
- 676
- References
- 34
- FWCI
- 24.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Official ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians. https://app.cochat.ai/papers/10.1183/13993003.00010-2017
- The paper
- Stanojevic, S., Graham, B. L., Cooper, B. G., Thompson, B. R., Carter, K. W., Francis, R. W., & Hall, G. L. (2017). Official ERS technical standards: Global Lung Function Initiative reference values for the carbon monoxide transfer factor for Caucasians. European Respiratory Journal. https://doi.org/10.1183/13993003.00010-2017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.