CoChat

International consensus guideline for reporting transmission electron microscopy results in the diagnosis of primary ciliary dyskinesia (BEAT PCD TEM Criteria)

Open access
Shoemark, Amelia, Boon, Mieke, Brochhausen, Christoph, Bukowy-Bieryllo, Zuzanna, De Santi, Maria M., Goggin, Patricia, Griffin, Paul, Hegele, Richard G., Hirst, Robert A., Leigh, Margaret W., Lupton, Alison, MacKenney, Karen, Omran, Heymut, Pache, Jean-Claude, Pinto, Andreia, Reinholt, Finn P., Schroeder, Josep, Yiallouros, Panayotis, Escudier, Estelle · 2020 · European Respiratory Journal
Cited by 163

The DOI matches its Crossref record.

Abstract

Primary ciliary dyskinesia (PCD) is a heterogeneous genetic condition. European and North American diagnostic guidelines recommend transmission electron microscopy (TEM) as one of a combination of tests to confirm a diagnosis. However, there is no definition of what constitutes a defect or consensus on reporting terminology. The aim of this project was to provide an internationally agreed ultrastructural classification for PCD diagnosis by TEM. A consensus guideline was developed by PCD electron microscopy experts representing 18 centres in 14 countries. An initial meeting and discussion were followed by a Delphi consensus process. The agreed guideline was then tested, modified and retested through exchange of samples and electron micrographs between the 18 diagnostic centres. The final guideline a) provides agreed terminology and a definition of Class 1 defects which are diagnostic for PCD; b) identifies Class 2 defects which can indicate a diagnosis of PCD in combination with other supporting evidence; c) describes features which should be included in a ciliary ultrastructure report to assist multidisciplinary diagnosis of PCD; and d) defines adequacy of a diagnostic sample. This tested and externally validated statement provides a clear guideline for the diagnosis of PCD by TEM which can be used to standardise diagnosis internationally.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/13993003.00725-2019

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Shoemark, A., Boon, M., Brochhausen, C., Bukowy-Bieryllo, Z., De Santi, M. M., Goggin, P., Griffin, P., Hegele, R. G., Hirst, R. A., Leigh, M. W., Lupton, A., MacKenney, K., Omran, H., Pache, J.-C., Pinto, A., Reinholt, F. P., Schroeder, J., Yiallouros, P., & Escudier, E.
Venue
European Respiratory Journal
Published
2020-02-14
Volume
55
Issue
4
Pages
1900725
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W3006129532
Cited by
163
References
0
FWCI
9.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: International consensus guideline for reporting transmission electron microscopy results in the diagnosis of primary ciliary dyskinesia (BEAT PCD TEM Criteria). https://app.cochat.ai/papers/10.1183/13993003.00725-2019
The paper
Shoemark, A., Boon, M., Brochhausen, C., Bukowy-Bieryllo, Z., De Santi, M. M., Goggin, P., Griffin, P., Hegele, R. G., Hirst, R. A., Leigh, M. W., Lupton, A., MacKenney, K., Omran, H., Pache, J.-C., Pinto, A., Reinholt, F. P., Schroeder, J., Yiallouros, P., & Escudier, E. (2020). International consensus guideline for reporting transmission electron microscopy results in the diagnosis of primary ciliary dyskinesia (BEAT PCD TEM Criteria). European Respiratory Journal. https://doi.org/10.1183/13993003.00725-2019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.